MGB-L1HE-APA-R-173351 (Sip. No. 173351)
Locking set MGB-L1HE-APA..., (guard locking by spring force) with 3 pushbuttons, emergency stop, RC18, M12, on mounting plates
- Guard locking with guard lock monitoring
- Emergency stop according to ISO 13850
- 3 pushbuttons (2 illuminated)
- With plug connector RC18
- With plug connector M12 for signal light
- With escape release
- Mounted on mounting plate
- Unicode

Açıklama
Guard locking type
| MGB-L1... | The locking arm is held in the locked position by spring force and is unlocked by solenoid force (closed-circuit current principle, mechanically locked). | 
Door hinge
A mechanical door stop is permanently integrated into the evaluation module of the MGB. A marking on the stop makes adjustment easier.
LED indicator
The LED indicator indicates all important system and status information.
Monitoring outputs
| OI | Diagnostics; there is a fault | 
Emergency stop device
| S1 | 2 positively driven contacts, emergency stop with turn-to-reset, not illuminated | 
Pushbuttons
| S2 | 1 NO contact, illuminated | 
| S3 | 1 NO contact, illuminated | 
| S4 | 1 NO contact, not illuminated | 
Escape release
The escape release enables people accidentally shut in to open the guard locked door from the danger zone.
Notice
The interlocking module is pre-assembled on a mounting plate.



Dimensional drawings

Dimensional drawings

Connection examples

Teknik Veriler
Approvals



Escape release MGB-E-A2-106051 (Order no. 106051)
 
    Mechanical values and environment
| Installation orientation | any | 
| Mechanical life | 1 x 10⁶ | 
| Ambient temperature | -30 ... 55 °C | 
| Material | |
| Housing | Die-cast zinc/stainless steel, powder-coated | 
Miscellaneous
| Product version number | V2.0.0 | 
| Additional feature | with mounting plate | 
Handle modules MGB-H-AA1A6-R-111838 (Order no. 111838)
 
    Mechanical values and environment
| Installation orientation | Door hinge DIN right | 
| Degree of protection | IP65 | 
| Ambient temperature | -20 ... 55 °C | 
| Material | |
| Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel | 
Miscellaneous
| Product version number | V3.0.0 | 
| Additional feature | with mounting plate and automatic lockout mechanism | 
Locking modules MGB-L1-APA-AP5A2-S10-R-173061 (Order no. 173061)
 
    Operating and display elements
| Occupancy diagram | L1 | 
| Item | Color | Extras | Slide-in label | Version | Note slide-in label | Switching element | Number | Designation1 | LED | 
|---|---|---|---|---|---|---|---|---|---|
| 1 | Emergency stop | 2 PD | |||||||
| 2 | Illuminated pushbutton | 1NO | |||||||
| 3 | Illuminated pushbutton | 1NO | |||||||
| 4 | Pushbutton, not illuminated | 1NO | 
Electrical connection values
| Rated insulation voltage Ui | 30 V | 
| Rated impulse voltage Uimp | 1.5 kV | 
| Discrepancy time | |
| between FO1A and FO1B | max. 10 ms | 
| Utilization category | |
| DC-13 | 24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) | 
| Risk time according to EN 60947-5-3 | max. 350 ms | 
| Safety class | III | 
| Transponder coding | Unicode | 
| Degree of contamination (external, according to EN 60947-1) | 3 | 
| Solenoid control input IMP1, IMP2, IMM | |
| Test pulse duration | max. 5 ms | 
| Test pulse interval | min. 100 ms | 
| Controls and indicators | |
| Breaking capacity | max. 0.25 W | 
| Switching voltage | UA V | 
| Switching current | 1 ... 10 mA | 
| LED power supply | 24 V DC | 
| Emergency stop | |
| Breaking capacity | max. 0.25 W | 
| Switching voltage | 5 ... 24 V | 
| Switching current | 1 ... 100 mA | 
| LED power supply | 24 V DC | 
| Monitoring outputs OD, OT, OL, OI | |
| Output type | Semiconductor outputs, p-switching, short circuit-proof | 
| Output voltage | UA-2V ... UA V DC (Value at a switching current of 50mA without taking into account the cable lengths) | 
| Output current | max. 50 mA | 
| Safety outputs FO1A, FO1B | |
| Output type | Semiconductor outputs, p-switching, short circuit-proof | 
| Output voltage | |
| UFO1A /UFO1B LOW | 0 ... 1 V DC | 
| UFO1A /UFO1B HIGH | UB-2V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths) | 
| Output current | |
| per safety output FO1A / FO1B | 1 ... 200 mA | 
| Test pulse duration | max. 0.3 ms | 
| Test pulse interval | min. 100 ms | 
| Power supply UA | |
| Operating voltage DC | |
| UA | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) | 
| Current consumption | |
| IUA | max. 375 mA ((with energized guard locking solenoid and unloaded outputs OD, OT, OL, OI, +20 °C, 24V)) | 
| Power supply UB | |
| Operating voltage DC | |
| UB | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) | 
| Current consumption | |
| IUB | max. 80 mA ((no load on outputs)) | 
Mechanical values and environment
| Connection type | |
| Plug connector RC18 (X6) | |
| Plug connector SFF5 (X7) | |
| Installation orientation | Door hinge DIN right | 
| Mechanical life | |
| in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ | 
| 1 x 10⁶ | |
| Degree of protection | IP65 | 
| Ambient temperature | |
| at UB = 24 V DC | -20 ... 55 °C | 
| Material | |
| Housing | Fiber glass reinforced plastic; nickel-plated die-cast zinc; stainless steel | 
| Locking force FZh | 2000 N | 
| Guard locking principle | Closed-circuit current principle | 
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| Mission time | 20 y | 
| Control of guard locking | |
| Category | 4 | 
| Performance Level | PL e | 
| PFHD | 2.8 x 10-9 | 
| Emergency stop | |
| B10D | |
| Emergency stop | 0.13 x 10⁶ | 
| Monitoring of guard locking and the guard position | |
| Category | 4 | 
| Performance Level | PL e | 
| PFHD | 3.7 x 10-9 | 
Miscellaneous
| Product version number | V4.0.0 | 
| Additional feature | |
| incl. lens set, ID no. 172974 | |
| Mounting plate | 
Bileşenler

MGB-E-A2-106051
Escape release module MGB-E... pre-assembled on mounting plate
- Escape release from the danger zone
- Mounted on mounting plate
- Signal red door handle
- Designed for door profiles up to 40 mm
- Extended actuation axis for thicker doors (available optionally)

MGB-H-AA1A6-R-111838
Handle module MGB-H... with automatically extending lockout mechanism
- Intelligent bolt tongue
- Fold-out lockout mechanism
- Second automatically extending lockout mechanism
- Door handle
- Mounting plate

MGB-L1-APA-AP5A2-S10-R-173061
Locking module MGB-L1-APA.., (guard locking by spring force) with 3 pushbuttons, emergency stop, RC18, M12, on mounting plates
- Guard locking with guard lock monitoring
- Emergency stop according to ISO 13850
- 3 pushbuttons (2 illuminated)
- With plug connector RC18
- With plug connector M12 for signal light
- Mounted on mounting plate
- Unicode
Aksesuar
İndirme
Komple paket
Tüm önemli belgeleri tek bir tıklama ile indirin.
İçerik:
- Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
- Kullanım talimatlarını tamamlayan tüm veri sayfaları
- Uygunluk beyanı
Tek Belgeler

















Diğer Belgeler





Sipariş verileri
| Sip. No. | 173351 | 
| Makale adı | MGB-L1HE-APA-R-173351 | 
| Ağırlık | 5,05kg | 
| Gümrük sınıfı | 85371098 | 
| ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking | 
 
				