AnasayfaProductsSafety engineering for connection to IO-LinkBP/BR safety switch with guard lockingCTM-I2-BR-M-ZZ-SA-P-174747
CTM-I2-BR-M-ZZ-SA-P-174747 (Sip. No. 174747)
Choose content
Transponder-coded safety switch CTM-I2-BR, M12
- Guard locking only suitable for process protection: The safety outputs are switched on when the door is closed.
- Series connection possible
- Open-circuit current principle
- Category 4 / PL e according to EN ISO 13849-1
- Actuating/extraction/retention force: 35/30/15 N
- Plug connector M12, 8-pin
- Multicode
- Hygienic version

Açıklama
Multicode evaluation
Every suitable actuator is detected by the switch.
Guard locking type
CTM‑I2 | Guard locking actuated by power-ON and released by spring force (open-circuit current principle). |
Series connection
Safety switches in the version CTM-...-BR can be integrated into a BR device chain. You will find further information about series connection in the operating instructions for the device.
Connector assignment


Dimensional drawings

1 | LEDs |
2 | Active read head face |
Connection examples

Teknik Veriler
Approvals



Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | 10 % |
Electrical connection values
Fuse | |
external (operating voltage UB) | 0.7 ... 8 A |
Power consumption | |
at max. switching frequency | 3 W |
Rated insulation voltage Ui | 50 V |
Rated impulse voltage Uimp | 0.5 kV |
Discrepancy time | |
both safety outputs | max. 10 ms |
Turn-on time | max. 100 ms |
Solenoid duty cycle | 100 % |
Off-state current Ir | max. 0.25 mA |
Risk time according to EN 60947-5-3 | max. 200 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 10 ms |
Switching load | DC 24V, UL Class 2 |
Safety class | III |
Test pulse duration | max. 0.3 ms |
Test pulse interval | 100 ms |
Degree of contamination (external, according to EN 60947-1) | 3 |
Solenoid IMP | |
Input voltage | |
Guard locking active (closed) | 20.4 ... 26.4 V DC |
Guard locking not active (open) | 0 ... 5 V DC |
Current consumption | |
Guard locking active (closed) | 20 ... 50 mA |
Door position monitoring output/communication OD/C | |
Output type | p-switching, short circuit-proof |
Output voltage | 0.8xUB ... UB V DC |
Switching current | 1 ... 50 mA |
Safety input | |
Current consumption | max. 7 mA Safety inputs Fl1A/Fl1B |
Safety outputs FO1A/FO1B | |
Output type | 2 semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
HIGH U(FO1A) / U(FO1B) | UB-1.5 ... UB V DC |
Discrepancy time | |
both safety outputs | max. 10 ms Acc. to EN IEC 60947-5-3 |
Turn-on time | max. 400 ms |
Utilization category | |
DC-13 | 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads) |
Off-state current Ir | max. 0.25 mA |
Risk time according to EN 60947-5-3 | max. 200 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 10 ms |
Electrical switching frequency | max. 0.25 Hz |
Switching current | |
per safety output FO1A / FO1B | 1 ... 150 mA |
Test pulse duration | max. 0.3 ms (Applies to a load with C<= 30nF and R<= 20kOhm) |
Test pulse interval | 100 ms |
Operating voltage UB | |
Operating voltage DC | |
UUB | 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV |
Current consumption | |
IUB at operating voltage UB = 24 V | max. 500 mA |
Mechanical values and environment
Approach speed | max. 20 m/min |
Connection type | Plug connector M12, 8-pin |
Extraction force | 30 N |
Ready delay | 5.5 s |
Actuating force | 35 N |
Installation orientation | any |
Switching frequency | max. 0.25 Hz |
Mechanical life | 1 x 10⁶ |
Overtravel | 2 mm |
Retention force | 15 N |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP65/IP67 (In the inserted and screwed tight state) |
Ambient temperature | |
at UB = 24V DC | -20 ... 60 °C |
Material | |
Safety switch housing | Reinforced thermoplastic |
Seals | Fluorinated rubber (FKM) |
Locking force Fmax | 1300 N |
Locking force FZh | 1000 N |
Guard locking principle | Open-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Monitoring of the guard position | PL e | 3 | 4.11x10-9 | 4 | 20 y |
Miscellaneous
Notices for UL approval | Operation only with UL Class 2 power supply or equivalent measures; see operating instructions |
Aksesuar
Connection material
İndirme
Komple paket
Tüm önemli belgeleri tek bir tıklama ile indirin.
İçerik:
- Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
- Kullanım talimatlarını tamamlayan tüm veri sayfaları
- Uygunluk beyanı
Paketin tamamını indirin (ZIP, 4,3 MB)
Tek Belgeler
Declarations of conformity
EU-Konformitätserklärung
Dok. No.
Versiyon
Dil
Boyut

EU-Konformitätserklärung
Dok. No.
EDC2525461
Versiyon
Dil
Boyut
0,5 MB
UKCA-Konformitätserklärung
Dok. No.
Versiyon
Dil
Boyut

UKCA-Konformitätserklärung
Dok. No.
EDC20001477
Versiyon
Dil
Boyut
0,1 MB
Instructions
Operating Instructions Transponder-Coded Safety Switch with Guard Locking for Process Protection CTM-I2-BP/BR Unicode/Multicode
Dok. No.
Versiyon
Dil
Boyut

Operating Instructions Transponder-Coded Safety Switch with Guard Locking for Process Protection CTM-I2-BP/BR Unicode/Multicode
Dok. No.
MAN20001437
Versiyon
10/24
Dil
Boyut
2,3 MB

Mode d’emploi Interrupteur de sécurité à codage par transpondeur avec interverrouillage pour la protection du process CTM-I2-BP/BR Uni-/multicode
Dok. No.
MAN20001437
Versiyon
10/24
Dil
Boyut
2,3 MB

Manual de instrucciones Interruptor de seguridad codificado por transponder con bloqueo para la protección de procesos CTM-I2-BP/BR Unicode/Multicode
Dok. No.
MAN20001437
Versiyon
10/24
Dil
Boyut
2,3 MB

Betriebsanleitung Transpondercodierter Sicherheitsschalter mit Zuhaltung für den Prozessschutz CTM-I2-BP/BR Uni-/Multicode
Dok. No.
MAN20001437
Versiyon
10/24
Dil
Boyut
2,3 MB
Diğer Belgeler
Approvals and certificates
FCC
Dok. No.
Versiyon
Dil
Boyut

FCC
Dok. No.
Versiyon
Dil
Boyut
0,1 MB
ISED
Dok. No.
Versiyon
Dil
Boyut

ISED
Dok. No.
Versiyon
Dil
Boyut
1,2 MB
UQS CTM-.2-…
Dok. No.
Versiyon
Dil
Boyut

UQS CTM-.2-…
Dok. No.
ECO20001482
Versiyon
Dil
Boyut
0,2 MB
c UL us
Dok. No.
Versiyon
Dil
Boyut

c UL us
Dok. No.
Versiyon
Dil
Boyut
0,3 MB
Sales documents
Communication du futur – industrie 4.0
Dok. No.
Versiyon
Dil
Boyut

Communication du futur – industrie 4.0
Dok. No.
159044
Versiyon
08-03/23
Dil
Boyut
4,7 MB
Future-proof Communication – Industry 4.0
Dok. No.
Versiyon
Dil
Boyut

Future-proof Communication – Industry 4.0
Dok. No.
159043
Versiyon
08-03/23
Dil
Boyut
5,8 MB
La comunicación del futuro: la industria 4.0
Dok. No.
Versiyon
Dil
Boyut

La comunicación del futuro: la industria 4.0
Dok. No.
159045
Versiyon
08-03/23
Dil
Boyut
5,8 MB
Zukunftsfähige Kommunikation – Industrie 4.0
Dok. No.
Versiyon
Dil
Boyut

Zukunftsfähige Kommunikation – Industrie 4.0
Dok. No.
159042
Versiyon
08-03/23
Dil
Boyut
5,8 MB
小型ながら大 きなメリット - ガードロック付きトランスポンダ ー・コーデッド安全スイッチ CTM
Dok. No.
Versiyon
Dil
Boyut

小型ながら大 きなメリット - ガードロック付きトランスポンダ ー・コーデッド安全スイッチ CTM
Dok. No.
166084
Versiyon
03-07/21
Dil
Boyut
4,7 MB
面向未来的通信 – 工业4.0
Dok. No.
Versiyon
Dil
Boyut

面向未来的通信 – 工业4.0
Dok. No.
164814
Versiyon
06-05/21
Dil
Boyut
6,2 MB
Sipariş verileri
Sip. No. | 174747 |
Makale adı | CTM-I2-BR-M-ZZ-SA-P-174747 |
Ağırlık | 0,26kg |
Gümrük sınıfı | 85365019000 |
ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |