TZ2LE110M (Sip. No. 083162)

Safety switch TZ, cable entry M20 x 1.5

  • Cable entry M20 x 1.5
  • Auxiliary release
  • LED indicator
  • Actuating head fitted left
  • Open-circuit current principle
TZ2LE110M (Sip. No. 083162)

Açıklama

Approach direction

Horizontal

Can be adjusted in 90° steps

Guard locking principle

Open-circuit current (power to lock): On a guard with guard locking based on the open-circuit current principle, the guard is locked until the power supply to the guard locking solenoid is interrupted. Unlocking is by spring force. The term electrical guard locking is also used.

LED indicator

The switch has two freely assignable LED indicators (red and green).

Switching element

SK

528

Slow-action switching contact

Contacts for door monitoring: 1 positively driven contact + 1 NO contact

ÜK

528

Slow-action switching contact

Contacts for guard locking: 1 positively driven contact + 1 NO contact

Auxiliary release

The auxiliary release on the front makes it possible to access the machine if there is a malfunction, e.g. a power failure. Unlocking is performed using a tool or a key. The auxiliary release must be protected against misuse (sealing, lacquer).

Accessories required

Actuator is not included.

Schaltfunktion
Schaltfunktion
Maßzeichnung
Maßzeichnung
Anschlussplan SK:528H/ÜK:528H
Anschlussplan SK:528H/ÜK:528H
Electromechanical safety switches in use

Functional drawings

Functional drawings

Dimensional drawings

Dimensional drawings
1Auxiliary release

Connection examples

Connection examples
square_grey_dark.epsDoor monitoring
square_grey_light.epsSolenoid monitoring

Teknik Veriler

Approvals

EAC_RU C-DE.MO05.B.00971/20DNV-GL_TAA0000172 Rev. 1DGUV_TZ_ET 24013_ET 24014CCC2024010305643586_SafetySwitch T_STc_UL_us_E155795_2/1

Operating and display elements

LED display Operating voltage corresponds to the solenoid voltage (2 LEDs; green, red)

Electrical connection values

Power consumption 10 W
Connection cross section 0.34 ... 1.5 mm²
Rated insulation voltage Ui 250 V
Rated impulse voltage Uimp 2.5 kV
Utilization category
DC-13 4 A 24 V (>70 °C =>2 A)
AC-15 4 A 230 V (>70 °C =>2 A)
Short circuit protection according to IEC 60269-1 4A gG (> 70 °C => 2A gG)
Solenoid operating voltage
AC 110 V -15% ... +10%
Solenoid duty cycle 100 %
Switching voltage
min. at 10 mA 12 V
Switching current
min. at 24 V 1 mA
thermal rated current Ith 4 A (>70 °C =>2 A)

Mechanical values and environment

Approach speed max. 20 m/min
Approach direction
Actuating head left C
Connection type
1 x M20 x 1.5
Number of door position NO contacts 1
Number of guard lock monitoring NO contacts 1
Number of door position positively driven contacts 1
Number of guard lock monitoring positively driven contacts 1
Extraction force 30 N
Actuation frequency max. 1200 1/h
Actuating force 35 N
Lid black
Installation orientation any
Insertion depth 52 mm
Mechanical life 1 x 10⁶
Retention force 10 N
Switching principle Slow-action switching contact
Degree of protection IP67
Ambient temperature -25 ... +80 °C
Material
Housing Anodized die-cast alloy
Contact Silver alloy, gold flashed
Locking force Fmax 2000 N
Locking force FZh 1500 N
Guard locking principle Open-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

B10DMission time
Monitoring of the guard position3x10620 y
Important! Values valid at DC-13 100 mA/24V
Monitoring of guard locking3x10620 y
Important! Values valid at DC-13 100 mA/24V


In combination with actuator ACTUATOR-Z-G

Overtravel 4 mm

In combination with actuator ACTUATOR-Z-GN

Overtravel 16 mm

Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 17,5 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 083162
Makale adı TZ2LE110M
Ağırlık 1,199kg
Gümrük sınıfı 85365019000
ECLASS 27-27-26-03 Safety switch with guard control