EUCHNER – More than safety.
EUCHNER – More than safety.

MGB-CB-PN-114744 (Sip. No. 114744)

Control panel MGB-...-PN with 13 control elements, push-pull plug, connection for stack light, RC12

  • Control panel
  • Emergency stop according to ISO 13850
  • 6 illuminated pushbuttons
  • 6 selector switch, 3-stage, illuminated
  • including adhesive labels
  • Push-pull plug
  • including terminal plug for stack light (M12, 8-pin)
  • including terminal plug for enabling switch (RC12, 12-pin)
  • Pre-assembled on mounting plates
  • Integrated Profinet RT switch
MGB-CB-PN-114744 (Sip. No. 114744)

Açıklama

Profinet connection

Connection via push-pull plugs according to IEC 61076-3-117

Profinet RT switch

Point-to-point topology network structure due to integrated RT switch.

Dimension drawing
Dimension drawing
MGB: impact test
MGB: mounting door on right, without escape release
MGB: mounting door on left, with escape release
MGB: mounting door on left, without escape release
MGB: in use
MGB: deactivating guard lock monitoring
MGB: pushbutton lens replacement
MGB: activating release monitoring
MGB: activating guard lock monitoring

Dimensional drawings

Dimensional drawings

Teknik Veriler

Approvals

EAC_RU C-DE.HX37.B.14157/20

Operating and display elements

Occupancy diagram
B1
C1
ItemColorExtrasSwitching elementVersionNote slide-in labelSlide-in labelNumberDesignation1LED
10white1NOIlluminated pushbutton
11white1NOIlluminated pushbutton
12white1NOIlluminated pushbutton
13white1NOIlluminated pushbutton
142NOSelector switch, illuminated
152NOSelector switch, illuminated
162NOSelector switch, illuminated
172NOSelector switch, illuminated
90white1NOIlluminated pushbutton
91white1NOIlluminated pushbutton
932 PDEmergency stop
942NOSelector switch, illuminated
952NOSelector switch, illuminated

Electrical connection values

Connecting cable
Ethernet Profinet I/O cable, at least cat. 5e
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0.5 kV
EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
maximum feed-in current in the connection block
X1, X2 max. 4000 mA
Safety class III
Current consumption max. 500 mA
Degree of contamination (external, according to EN 60947-1) 3
Power supply X1
Fuse
external min. 1 A slow blow
Operating voltage DC
L1 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
Power supply X2
Operating voltage DC
L1 24 V DC -15% ... +10% (For looping through for connected devices)
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (For looping through for connected devices)

Mechanical values and environment

Connection type
for Stacklight Plug connector M12 (X6)
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e Push-pull RJ45 (X4 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
for enabling switch Plug connector RC12 (X14)
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e Push-pull RJ45 (X3 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
Push-pull power (X2 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
Push-pull power (X1 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
Installation orientation any
Switching frequency 0.25 Hz
Response time
Enabling switch max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Emergency stop / machine stop max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP54
Ambient temperature
at UB = 24 V DC -20 ... +55 °C
Material
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Diagnostic Coverage (DC) 99 %
PLMaximum SILPFHDCategoryMission time
Evaluating safety signalsPL e34.1x10-8420 y
Applies to all additionally included safety functions such as EMERGENCY STOP, enabling switch, etc.


B10DMission time
Emergency stop0.13x10620 y


Miscellaneous

Slide-in label
NumberLabelingNote
12without marking
Quittierungssymbol 2
Quittierungssymbol 1
Product version number V3.30.10

Interface

Bus data protocol Profinet (IEC 61158 type 10)
Safety data protocol Profisafe (IEC 61784-3-3)
Date interface
Ethernet

Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 6,5 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 114744
Makale adı MGB-CB-PN-114744
Ağırlık 3,077kg
Gümrük sınıfı 85371098

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.