AnasayfaProductsTransponder-coded read heads with external evaluationField evaluation unit CES-FDCES-FD-AP-M-01-USI-115534
CES-FD-AP-M-01-USI-115534 (Sip. No. 115534)
Choose content
Field evaluation unit CES-FD-AP-…
- Connection of a CES/CKS read head
- Evaluation of signals in the field
- Connection to the ET200s and ET200pro
- Familiar EUCHNER AP interface
- Multicode

Açıklama
Short circuit monitoring
The switch generates its own clock signal on the output lines FO1A/FO1B. Pay attention to this aspect when connecting to control systems and relays.
Category according to EN ISO 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- Category 4 / PL e according to EN ISO 13849-1
Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (F01A and F01B) must always be evaluated.
LED indicator
STATE | Status LED |
DIA | Diagnostics LED |
Connection for control system


Dimensional drawings

| 1 | LED status indication |
| 2 | Fastening lug with reinforcement plate |
| 3 | Coding lug |
| 4 | Cable length 1000 millimeters |
| 5 | Cable length 200 millimeters |
Connection examples

Teknik Veriler
Approvals


Workspace
| Repeat accuracy R | |
| according to EN 60947-5-2 | 10 % |
Electrical connection values
| Fuse | |
| external (operating voltage) | 0.25 ... 8 A |
| Rated insulation voltage Ui | 75 V |
| Rated impulse voltage Uimp | 1.5 kV |
| Operating voltage DC | |
| UB (PELV, see operating instructions) (reverse polarity protected, regulated, residual ripple<5%) | 24 V DC -15% ... +15% (The device tolerates voltage interruptions in the operating voltage, e.g. test pulses, of up to 5 ms. These voltage interruptions are also output on the safety outputs.) |
| Turn-on time | |
| Safety outputs | max. 400 ms |
| EMC protection requirements | Acc. to EN IEC 60947-5-3 |
| Risk time according to EN 60947-5-3 | max. 260 ms |
| Safety class | III |
| Current consumption | max. 45 mA |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| Safety outputs FO1A/FO1B | |
| Output type | Semiconductor outputs, p-switching, short circuit-proof |
| Output voltage | |
| HIGH U(FO1A) / U(FO1B) | UB-1.5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.) |
| LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
| rated conditional short-circuit current | 100 A |
| Discrepancy time | max. 10 ms |
| Utilization category | |
| DC-13 | 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
| Off-state current Ir | max. 0.25 mA |
| Switching current | |
| per safety output | 1 ... 150 mA |
| Test pulse duration | max. 0.3 ms (Applies to a load with C<= 30nF and R<= 20kOhm) |
| Test pulse interval | min. 100 ms |
Mechanical values and environment
| Connection type | Connecting cable PUR with plug connector M12, 5-pin; pin 5 not used |
| Tightening torque | |
| Fixing screws | max. 1 Nm |
| Ready delay | 1 s |
| Installation orientation | any |
| Switching frequency | max. 1 Hz |
| Storage temperature | -25 ... 70 °C |
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
| Degree of protection | IP65/IP67 |
| Cable ambient temperature (dynamic) | -5 ... 65 °C |
| Cable ambient temperature (static) | -20 ... 65 °C |
| Material | |
| Housing | Plastic, PBT |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| PL | Maximum SIL | PFHD | Category | Mission time | |
|---|---|---|---|---|---|
| Monitoring of the guard position | PL e | - | 4.5x10-9 | 4 | 20 y |
Miscellaneous
| Notices for UL approval | Operation only with UL Class 2 power supply or equivalent measures |
In combination with read head CES-A-LMN-SC and actuator CES-A-BMB
| Switch-on distance | 5 mm (with read head CES-A-LMN-SC and actuator CES-A-BMB) |
| Secured switch-off distance sar | max. 10 mm (with read head CES-A-LMN-SC and actuator CES-A-BMB) |
| Secured switching distance sao | min. 3.4 mm (with read head CES-A-LMN-SC and actuator CES-A-BMB) |
| Switching hysteresis | 0.05 ... 0.2 mm (with read head CES-A-LMN-SC and actuator CES-A-BMB) |
Aksesuar
Connection material
İndirme
Komple paket
Tüm önemli belgeleri tek bir tıklama ile indirin.
İçerik:
- Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
- Kullanım talimatlarını tamamlayan tüm veri sayfaları
- Uygunluk beyanı
Paketin tamamını indirin (ZIP, 1,8 MB)
Tek Belgeler
Diğer Belgeler
Application examples
Approvals and certificates
UQS CES-FD-AP…
Dok. No.
Versiyon
Dil
Boyut
UQS CES-FD-AP…
Dok. No.
ECO2116784
Versiyon
Dil
Boyut
0,2 MB
WEEE
Dok. No.
Versiyon
Dil
Boyut
WEEE
Dok. No.
ECO20001806
Versiyon
Dil
Boyut
0,1 MB
c UL us
Dok. No.
Versiyon
Dil
Boyut
c UL us
Dok. No.
Versiyon
Dil
Boyut
0,3 MB
Sales documents
Flexibly safe - Transponder-coded safety systems CES
Dok. No.
Versiyon
Dil
Boyut
Flexibly safe - Transponder-coded safety systems CES
Dok. No.
120233
Versiyon
06-06/22
Dil
Boyut
7,3 MB
CAD Verileri
Sipariş verileri
| Sip. No. | 115534 |
| Makale adı | CES-FD-AP-M-01-USI-115534 |
| Ağırlık | 0,121kg |
| Gümrük sınıfı | 85365019000 |
| ECLASS | 27-27-24-03 Safety-related transponder switch |