CTM-CBI-BP-HC-FLX-AZ-SA-170490 (Sip. No. 170490)
Transponder-coded safety switch CTM-CBI-BP, M12
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuating/extraction/retention force: 20/18/5 N
- Plug connector M12, 8-pin
- Auxiliary release
- Highly coded
- FlexFunction device

Açıklama
Highly coded evaluation
Each actuator is highly coded (HC). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.
Guard locking type
CTM‑CBI | Guard locking operated by means of input signal. |
The switch can be configured with the aid of the function actuator. Guard lock monitoring is switched on or off depending on the taught-in function actuator.
This type of guard locking has a function to prevent
- persons from unintentionally locking themselves inside if the safety door is open in case of a power failure or if the machine is switched off.
- the deactivation of the activated guard locking in case of a power failure.
FlexFunction
The actuator configures the switch during setup. Depending on the actuator selected, guard lock monitoring of the safety switch is active or inactive.
Connector assignment


Dimensional drawings

| 1 | LEDs |
| 2 | Active read head face |
| 3 | Auxiliary release |
Connection examples

Teknik Veriler
Approvals


Workspace
| Repeat accuracy R | 10 % |
Electrical connection values
| Fuse | |
| external (operating voltage UB) | 0.7 ... 8 A |
| Power consumption | |
| at max. switching frequency | 3 W |
| Rated insulation voltage Ui | 50 V |
| Rated impulse voltage Uimp | 0.5 kV |
| Discrepancy time | |
| both safety outputs | max. 10 ms Acc. to EN IEC 60947-5-3 |
| Turn-on time | max. 400 ms |
| Solenoid duty cycle | 100 % |
| Off-state current Ir | max. 0.25 mA |
| Risk time according to EN 60947-5-3 | max. 200 ms |
| Risk time according to EN 60947-5-3, extension for each additional device | max. 10 ms |
| Switching load | DC 24V, UL Class 2 (alternatively, see operating instructions) |
| Safety class | III |
| Test pulse duration | max. 0.3 ms |
| Test pulse interval | 100 ms |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| Solenoid IMP | |
| Input voltage | |
| Guard locking not active (open) | 20.4 ... 26.4 V DC |
| Guard locking active (closed) | 0 ... 5 V DC |
| Current consumption | |
| Guard locking not active (open) | 20 ... 50 mA |
| Diagnostic monitoring output OI, door position monitoring output/communication OD/C, guard lock monitoring output OL | |
| Output type | p-switching, short circuit-proof |
| Output voltage | 0.8xUB ... UB V DC |
| Switching current | 1 ... 50 mA |
| Safety outputs FO1A/FO1B | |
| Output type | 2 semiconductor outputs, p-switching, short circuit-proof |
| Output voltage | |
| LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
| HIGH U(FO1A) / U(FO1B) | UB-1.5 ... UB V DC |
| Discrepancy time | Acc. to EN IEC 60947-5-3 |
| Utilization category | |
| DC-13 | 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads) |
| Electrical switching frequency | max. 0.25 Hz |
| Switching current | |
| per safety output FO1A / FO1B | 1 ... 150 mA |
| Operating voltage UB | |
| Operating voltage DC | |
| UUB | 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV |
| Current consumption | |
| IUB at operating voltage UB = 24 V | max. 500 mA |
Mechanical values and environment
| Anfahrgeschwindigkeit | max. 20 m/min |
| Connection type | Plug connector M12, 8-pin |
| Extraction force | 18 N |
| Ready delay | 5.5 s |
| Actuating force | 20 N |
| Installation orientation | any |
| Switching frequency | max. 0.25 Hz |
| Storage temperature | -25 ... 70 °C |
| Mechanical life | 1 x 10⁶ |
| Overtravel | 2 mm |
| Retention force | 5 N |
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
| Degree of protection | IP65/IP67 (In the inserted and screwed tight state) |
| Ambient temperature | |
| at UB = 24 V DC | -20 ... 60 °C |
| Material | |
| Seals | Fluorinated rubber (FKM) |
| Safety switch housing | Reinforced thermoplastic |
| Locking force Fmax | 1300 N |
| Locking force FZh | 1000 N |
| Guard locking principle | BiState |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| PL | Maximum SIL | PFHD | Category | Mission time | |
|---|---|---|---|---|---|
| Control of guard locking | PL d | 2 | 1.03x10-7 | 3 | 20 y |
| Monitoring of the guard position | PL e | 3 | 4.11x10-9 | 4 | 20 y |
| Only applies with inactive guard lock monitoring (guard locking for process protection). Depending on the actuator used. | |||||
| Guard lock monitoring | PL e | 3 | 4.11x10-9 | 4 | 20 y |
| Applies only if guard lock monitoring is active (guard locking for protection of personnel). Dependent on the actuator used. | |||||
Miscellaneous
| Notices for UL approval | Operation only with UL Class 2 power supply or equivalent measures; see operating instructions |
Aksesuar

A-FLX-B-08-A1-A1-170487
- Use only in combination with CTM-CBI and CTM-C2 device variants
- Actuator for configuration of the switch with guard lock monitoring
- Ball actuator, rigid
- Door radii from 150 mm
- Two safety screws M4x14 are included.

A-FLX-B-09-A1-A1-170488
- Use only in combination with CTM-CBI and CTM-C2 device variants
- Actuator for configuration of the switch without guard lock monitoring
- Ball actuator, rigid
- Door radii from 150 mm
- Two safety screws M4x14 are included.
İndirme
Komple paket
Tüm önemli belgeleri tek bir tıklama ile indirin.
İçerik:
- Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
- Kullanım talimatlarını tamamlayan tüm veri sayfaları
- Uygunluk beyanı
Tek Belgeler
Diğer Belgeler
Sipariş verileri
| Sip. No. | 170490 |
| Makale adı | CTM-CBI-BP-HC-FLX-AZ-SA-170490 |
| Ağırlık | 0,26kg |
| Gümrük sınıfı | 85365019000 |
| ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |