Transponder-coded safety switch CTP-AP, M12, ATEX
- ATEX version
- Suitable for use in zones 2 and 22 (gases and dusts)
- Safety switch with guard locking and integrated evaluation electronics
- With escape release
- 2 safety outputs (semiconductor outputs)
- Up to category 4 / PL e according to EN ISO 13849-1
- With plug connector M12
- Unicode
- Door monitoring output OD
- Guard lock monitoring output OL
- Approach directions A, B and C (delivery state)

Açıklama
Mounting plate
A mounting plate for supporting the escape release is included.
Unicode evaluation
Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.
Guard locking type
CTP‑L1 | Guard locking actuated by spring force and power-ON released (closed-circuit current principle). |
Connector assignment
Dimensional drawings

| 1 | Auxiliary release |
| 2 | Locking screw |
| 3 | LEDs |
| 4 | Protective plate |
| 5 | Grounding terminal - for preventing electrostatic charging. Ground switch via cable. Cable cross-section 4...6 mm² |
| 6 | Escape release |
| 7 | Mounting plate |
Connection examples

Teknik Veriler
Approvals



Workspace
| Repeat accuracy R | |
| according to EN 60947-5-2 | 10 % |
Electrical connection values
| Fuse | |
| external (solenoid operating voltage IMP) | 0.5 ... 8 A |
| external (operating voltage UB) | 0.25 ... 8 A |
| Power consumption | 6 W |
| Rated insulation voltage Ui | 50 V |
| Rated impulse voltage Uimp | 0.5 kV |
| Operating voltage DC | |
| UUB | 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV |
| EMC protection requirements | Acc. to EN IEC 60947-5-3 |
| Utilization category | |
| DC-13 | 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads) |
| Solenoid operating voltage DC | |
| UIMP | 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV |
| Solenoid duty cycle | 100 % |
| Switching load | |
| according to UL | 24V DC, Class 2 (alternatively, see operating instructions) |
| Safety class | III |
| Current consumption | |
| IUB | 40 mA |
| IIMP | 400 mA |
| Test pulse duration | max. 0.3 ms (Applies to a load with C<= 30nF and R<= 20kOhm) |
| Test pulse interval | min. 100 ms |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| Monitoring output OD, OL | |
| Output type | p-switching, short circuit-proof |
| Output voltage | 0.8xUB ... UB V DC |
| Switching current | 1 ... 50 mA |
| Safety outputs FO1A/FO1B | |
| Output type | 2 semiconductor outputs, p-switching, short circuit-proof |
| Output voltage | |
| LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
| HIGH U(FO1A) / U(FO1B) | UB-1.5 ... UB V DC |
| Discrepancy time | |
| both safety outputs | max. 10 ms Acc. to EN IEC 60947-5-3 |
| Turn-on time | max. 400 ms |
| Off-state current Ir | max. 0.25 mA |
| Switching current | |
| per safety output FO1A / FO1B | 1 ... 150 mA |
Mechanical values and environment
| Anfahrgeschwindigkeit | max. 20 m/min |
| Connection type | 1 plug connector M12, 8-pin |
| Extraction force | 20 N |
| Ready delay | max. 1 s |
| Actuating force | 10 N |
| Installation orientation | any |
| Switching frequency | max. 0.5 Hz |
| Storage temperature | -25 ... 70 °C |
| Mechanical life | 1 x 10⁶ |
| Overtravel | 5 mm |
| Retention force | 20 N |
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
| Degree of protection | IP65/IP66 (In the inserted and screwed tight state) |
| Ambient temperature | |
| at UB = 24 V DC | -20 ... 55 °C |
| Material | |
| Safety switch housing | Reinforced thermoplastic |
| Mounting plate | Aluminum |
| Protective plate | Stainless steel |
| Switch head cover | Die-cast zinc |
| Locking force Fmax | 3900 N |
| Locking force FZh | 3000 N (Fzh = Fmax/1.3, depending on the actuator used) |
| Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| PL | Maximum SIL | PFHD | Category | Mission time | |
|---|---|---|---|---|---|
| Guard lock monitoring | PL e | - | 4.1x10-9 | 4 | 20 y |
| PL | Maximum SIL | Category | Mission time | |
|---|---|---|---|---|
| Control of guard locking | Depending on external control of guard locking | 20 y | ||
Miscellaneous
| Explosion protection in accordance with ATEX Directive 2024/34/EU | II3G Ex ec IIC T4 Gc X / II3D Ex tc IIIC T110°C Dc X |
| Notices for UL approval | Operation only with UL Class 2 power supply or equivalent measures; see operating instructions |
| Additional feature | Escape release actuated by pushing |
Aksesuar
Actuator
Hinged actuator for safety switch CTP-EX, ATEX

166340
A-C-H-RL-LS-EX-166340
A-C-H-RL-LS-EX-166340
- Hinged actuator for doors hinged on the left
- ATEX version
- Suitable for use in zones 2 and 22 (gases and dusts)
- Two safety screws included

166341
A-C-H-RR-LS-EX-166341
A-C-H-RR-LS-EX-166341
- Hinged actuator for doors hinged on the right
- ATEX version
- Suitable for use in zones 2 and 22 (gases and dusts)
- Two safety screws included
Connection material
Mounting accessories
Efficient protection against tampering for safety switch mounting

161344
AM-C-SW4-V3-161344
AM-C-SW4-V3-161344
- Plastic inserts for hexagon socket screws a/f 4
- Efficient protection against tampering for safety switch mounting
- The packaging includes inserts for 18 screws

161348
AM-C-SW5-V3-161348
AM-C-SW5-V3-161348
- Plastic inserts for hexagon socket screws a/f 5
- Efficient protection against tampering for safety switch mounting
- The packaging includes inserts for 18 screws
İndirme
Komple paket
Tüm önemli belgeleri tek bir tıklama ile indirin.
İçerik:
- Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
- Kullanım talimatlarını tamamlayan tüm veri sayfaları
- Uygunluk beyanı
Paketin tamamını indirin (ZIP, 5,5 MB)
Tek Belgeler
Declarations of conformity
EU-Konformitätserklärung
Dok. No.
Versiyon
Dil
Boyut
EU-Konformitätserklärung
Dok. No.
EDC2127608
Versiyon
Dil
Boyut
0,2 MB
Instructions
Operating Instructions Transponder-Coded Safety Switch With Guard Locking CTP-AP-...-EX Unicode/Multicode
Dok. No.
Versiyon
Dil
Boyut
Operating Instructions Transponder-Coded Safety Switch With Guard Locking CTP-AP-...-EX Unicode/Multicode
Dok. No.
2127610
Versiyon
05-08/20
Dil
Boyut
2,0 MB
Mode d'emploi Interrupteur de sécurité à codage par transpondeur avec interverrouillage CTP-AP-...-EX uni-/multicode
Dok. No.
2127610
Versiyon
05-08/20
Dil
Boyut
2,0 MB
Manual de instrucciones Interruptor de seguridad con codificación por transponder con bloqueo CTP-AP-...-EX Unicode/Multicode
Dok. No.
2127610
Versiyon
05-08/20
Dil
Boyut
2,0 MB
Betriebsanleitung Transpondercodierter Sicherheitsschalter mit Zuhaltung CTP-AP-...-EX Uni-/Multicode
Dok. No.
2127610
Versiyon
05-08/20
Dil
Boyut
2,0 MB
Istruzioni di impiego Finecorsa di sicurezza con codifica a transponder con meccanismo di ritenuta CTP-AP-...-EX Uni-/Multicode
Dok. No.
2127610
Versiyon
05-08/20
Dil
Boyut
2,0 MB
Diğer Belgeler
Approvals and certificates
FCC
Dok. No.
Versiyon
Dil
Boyut
FCC
Dok. No.
Versiyon
Dil
Boyut
0,1 MB
UQS CTP-AP-AR_MGBS-AP-AR_
Dok. No.
Versiyon
Dil
Boyut
UQS CTP-AP-AR_MGBS-AP-AR_
Dok. No.
ECO2123565
Versiyon
Dil
Boyut
0,2 MB
WEEE
Dok. No.
Versiyon
Dil
Boyut
WEEE
Dok. No.
ECO20001806
Versiyon
Dil
Boyut
0,1 MB
c UL us
Dok. No.
Versiyon
Dil
Boyut
c UL us
Dok. No.
Versiyon
Dil
Boyut
0,3 MB
Sipariş verileri
| Sip. No. | 156240 |
| Makale adı | CTP-L1-AP-U-HA-AE-SA-EX-156240 |
| Ağırlık | 1,3kg |
| Gümrük sınıfı | 85365019000 |
| ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |