EUCHNER – More than safety.
EUCHNER – More than safety.

CES-AR-C01-AH-SA (Order no. 098941)

Non-contact safety switch CES-AR-C01...

  • Safety switch with integrated evaluation electronics
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4 / PL e according to EN ISO 13849-1
  • Unicode
CES-AR-C01-AH-SA (Order no. 098941)

Description

Approach direction

Can be adjusted in 90° steps

Short circuit monitoring

The switch generates its own clock signal on the output lines OA/OB. Pay attention to this aspect when connecting to control systems and relays.

Unicode evaluation

Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in.

Only the last actuator taught-in is detected.

Category according to EN 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4/PL e according to EN 13849-1

Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

LED indicator

STATE

Status LED

DIA

Diagnostics LED

Additional connections

OUT

Monitoring output (semiconductor)

RST

Reset input

Connector assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1IBEnable input for channel 2WH
2UBPower supply, DC 24 VBN
3OASafety output, channel 1GN
4OBSafety output, channel 2YE
5OUTMonitoring outputGY
6IAEnable input for channel 1PK
70VGround, DC 0 VBU
8RSTReset inputRD
Dimension drawing
Dimension drawing
Wiring drawing<br>Wiring diagram
Wiring drawing
Wiring diagram

Dimension drawings

Dimension drawings
1LED status indication
2Active face

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E346349_1/1c_UL_us_E155795_3/2DGUV_ET 18055_ET 18056

Work area

Repeat accuracy R
according to EN 60947-5-2 <= 10

Electrical connection ratings

Current consumption
no load on outputs max. 50 mA
Fusing
external (operating voltage) 0.25 ... 8 A
Rated insulation voltage Ui 300 V (Tested by the employers' liability insurance association up to 75 V)
Rated impulse withstand voltage Uimp 1.5 kV
Operating voltage DC
UB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple < 5%, PELV
Turn-on time
Safety outputs max. 400 ms
EMC protection requirements according to EN IEC 60947-5-3
Risk time according to EN 60947-5-3
Single device max. 260 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 5 ms
Safety class III
Degree of contamination (external, according to EN 60947-1) 3
Monitoring output OUT
Output type p-switching, short circuit-proof
Output voltage 0.8 x UB ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.)
Switching current max. 200 mA
Safety outputs OA / OB
Output type Semiconductor outputs, p-switching, short circuit-proof
rated conditional short-circuit current max. 100 A
Discrepancy time max. 10 ms
Output voltage
LOW U(OA,OB) 0 ... 1 V DC
HIGH U(OA,OB) UB-1.5 ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.)
Switching current
per safety output 1 ... 400 mA
Utilization category
DC-13 24V 400mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
Off-state current Ir max. 0.25 mA
Test pulses max. 1 ms

Mechanical values and environment

Connection M12 plug connector, 8-pin
Degree of protection IP67
Ready delay 10 s
Material
Housing Plastic, PBT
Installation orientation any
Switching frequency max. 1 Hz
Tightening torque
Fixing screws max. 1 Nm
Mounting distance min. 40 mm
Shock and vibration resistance according to EN IEC 60947-5-3
Ambient temperature -20 ... +55 °C

Reliability values acc. to EN ISO 13849-1

Mission time 20 y
Monitoring of the guard position
Category 4
Performance Level PL e
PFHD 2.1 x 10-9

Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures

In combination with actuator CES-A-BBA-071840

Assured operating distances sao min. 15 mm (The values apply to surface mounting)
Assured release distance sar max. 45 mm (The values apply to surface mounting)
Operating distance 18 mm
Switching hysteresis 1 ... 3 mm (The values apply to surface mounting)
Mounting distance

In combination with actuator CES-A-BPA-098775

Assured operating distances sao min. 18 mm
Assured release distance sar max. 58 mm
Operating distance 22 mm (on surface mounting on aluminum. In a non-metallic environment, the typical operating distances increase to 30 mm)
Switching hysteresis 1 ... 2 mm
Mounting distance

In combination with actuator CES-A-BDA-18-156935

Assured operating distances sao min. 10 mm (The values apply to surface mounting)
Assured release distance sar max. 45 mm (The values apply to surface mounting)
Operating distance 19 mm (The values apply to surface mounting)
Switching hysteresis 1 ... 3 mm (The values apply to surface mounting)
Mounting distance

In combination with actuator CES-A-BRN-100251

Assured operating distances sao min. 20 mm (The values apply to surface mounting of the actuator on steel.)
Assured release distance sar max. 75 mm
Operating distance 27 mm
Switching hysteresis 3 mm (The values apply to surface mounting of the actuator on steel.)
Mounting distance

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 14,7 MB)

Single Documents

Doc. no.
Version
Language
Size
Doc. no. 2098039
Operating Instructions Non-Contact Safety Switch CES-AR-C01-... (Unicode/Multicode/Fixcode)
Doc. no.
2098039
Version
20-02/20
Language
Size
1,6 MB
Doc. no. 2098039
Mode d'emploi Interrupteur de sécurité sans contact CES-AR-C01-... (unicode / multicode/ code fixe)
Doc. no.
2098039
Version
20-02/20
Language
Size
1,6 MB
Doc. no. 2098039
Manual de instrucciones Interruptor de seguridad sin contacto CES-AR-C01-... (Unicode/Multicode/Fixcode)
Doc. no.
2098039
Version
20-02/20
Language
Size
1,6 MB
Doc. no. 2098039
Betriebsanleitung Berührungsloser Sicherheitsschalter CES-AR-C01-... (Uni-/Multi-/Fixcode)
Doc. no.
2098039
Version
20-02/20
Language
Size
1,6 MB
Doc. no. 2098039
Istruzioni di impiego Finecorsa di sicurezza senza contatto CES-AR-C01-... (Uni-/Multi-/Fixcode)
Doc. no.
2098039
Version
20-02/20
Language
Size
1,6 MB
Doc. no. 2098039
使用说明书 非接触式安全开关 CES-AR-C01-⋯ (特殊/通用/固定编码)
Doc. no.
2098039
Version
20-02/20
Language
Size
2,1 MB
Doc. no. 2098039
Инструкция по эксплуатации Бесконтактный предохранительный выключатель CES-AR-C01-... (Uni-/Multi-/Fixcode)
Doc. no.
2098039
Version
20-02/20
Language
Size
2,1 MB
Doc. no. 2098039
Návod k použití Bezkontaktní bezpečnostní spínač CES-AR-C01-... (Unicode/Multicode/Fixcode)
Doc. no.
2098039
Version
20-02/20
Language
Size
2,8 MB
Doc. no. 2098039
Érintkezésmentes biztonsági kapcsoló CES-AR-C01-… (Uni-/multi-/állandó kód)
Doc. no.
2098039
Version
20-02/20
Language
Size
1,6 MB
Doc. no. 2098039
İşletim kılavuzu Temassız emniyet şalteri CES-AR-C01-... (Uni-/Multi-/Fixcode)
Doc. no.
2098039
Version
20-02/20
Language
Size
2,0 MB
Doc. no. 2098039
Instrucţiuni de utilizare Întrerupător de siguranţă fără contact CES-AR-C01-... (cod unic/mai multe coduri/cod fi x)
Doc. no.
2098039
Version
20-02/20
Language
Size
2,8 MB

Other Documents

Ordering data

Ordernumber 098941
Item designation CES-AR-C01-AH-SA
Gross weight 0,19kg
European Article Number (EAN) 4047048005433
Customs tariff number 85365019

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com