MGB-L2CB-PNC-R-114778 (Order no. 114778)
									Choose content
									
									
									
									
									
									
									
									
									
									Evaluation module with control and bus module MGB-...-PN with 11 controls and indicators, push-pull plug, RC12
- Control panel
- Emergency stop according to ISO 13850
- 8 illuminated pushbuttons
- Operating mode selector
- 1 indicator
- including adhesive labels
- Push-pull plug
- including terminal plug for enabling switch (RC12, 12-pin)
- Pre-assembled on mounting plates
- Integrated Profinet RT switch

Description
Profinet connection
Connection via push-pull plugs according to IEC 61076-3-117
Profinet RT switch
Point-to-point topology network structure due to integrated RT switch.

Dimensional drawings

Technical data
Approvals




Workspace
| Secured switch-off distance sar | |
| Only with sliding door | 20 mm (Only applies for use on sliding doors with deactivated guard lock monitoring) | 
Operating and display elements
| Occupancy diagram | |
| B2 | |
| C3 | |
| L2 | 
| Item | Color | Extras | Slide-in label | Note slide-in label | Version | Switching element | Number | Designation1 | LED | 
|---|---|---|---|---|---|---|---|---|---|
| 1 | green | Inicia estação | Illuminated pushbutton | 1NO | |||||
| 11 | green | Área segura | Signal indicator | ||||||
| 12 | yellow | Rearma área segura | Illuminated pushbutton | 1NO | |||||
| 13 | Destravada ; Travada ; Travada central | Operating mode selector | Code 2 of 3 | ||||||
| 2 | red | Para estação | Illuminated pushbutton | 1NO | |||||
| 3 | green | Liga água de refrigeração | Illuminated pushbutton | 1NO | |||||
| 4 | white | Fim de ciclo | Illuminated pushbutton | 1NO | |||||
| 5 | white | ohne Aufschrift | Illuminated pushbutton | 1NO | |||||
| 6 | red | Desliga água de refrigeração | Illuminated pushbutton | 1NO | |||||
| 7 | Emergency stop | 2 PD | |||||||
| 8 | white | Libera porta de segurança | Illuminated pushbutton | 1NO | 
Electrical connection values
| Connecting cable | |
| Ethernet | Profinet I/O cable, at least cat. 5e | 
| Rated insulation voltage Ui | 75 V | 
| Rated impulse voltage Uimp | 0.5 kV | 
| EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 | 
| maximum feed-in current in the connection block | |
| X1, X2 | max. 4000 mA | 
| Safety class | III | 
| Current consumption | max. 500 mA | 
| Transponder coding | Multicode | 
| Degree of contamination (external, according to EN 60947-1) | 3 | 
| Power supply X1 | |
| Fuse | |
| external | min. 1 A slow blow | 
| Operating voltage DC | |
| L1 | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) | 
| Auxiliary voltage DC | |
| L2 | 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system) | 
| Power supply X2 | |
| Operating voltage DC | |
| L1 | 24 V DC -15% ... +10% (For looping through for connected devices) | 
| Auxiliary voltage DC | |
| L2 | 24 V DC -15% ... +10% (For looping through for connected devices) | 
Mechanical values and environment
| Connection type | |
| according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e | Push-pull RJ45 (X4 (The document PROFINET 'Cabling and Interconnection Technology' from the PNO aids in the correct selection of cables.)) | 
| Push-pull power (X2 (The document PROFINET 'Cabling and Interconnection Technology' from the PNO aids in the correct selection of cables.)) | |
| Push-pull power (X1 (The document PROFINET 'Cabling and Interconnection Technology' from the PNO aids in the correct selection of cables.)) | |
| according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e | Push-pull RJ45 (X3 (The document PROFINET 'Cabling and Interconnection Technology' from the PNO aids in the correct selection of cables.)) | 
| for enabling switch | Plug connector RC12 (X14) | 
| Installation orientation | Door hinge DIN right | 
| Switching frequency | 0.25 Hz | 
| Storage temperature | -25 ... 70 °C | 
| Mechanical life | |
| in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ | 
| 1 x 10⁶ | |
| Response time | |
| Operating mode selector | max. 220 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) | 
| Enabling switch | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) | 
| Door position | max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) | 
| Emergency stop / machine stop | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) | 
| Bolt position | max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) | 
| Guard locking | max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) | 
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 | 
| Degree of protection | IP54 | 
| Ambient temperature | |
| at UB = 24 V DC | -20 ... 55 °C | 
| Material | |
| Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel | 
| Locking force FZh | 2000 N | 
| Guard locking principle | Open-circuit current principle | 
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| PL | Maximum SIL | PFHD | Category | Mission time | |
|---|---|---|---|---|---|
| Monitoring of the guard position | PL e | 3 | 4.07x10-8 | 4 | 20 y | 
| Guard lock monitoring | PL e | 3 | 4.07x10-8 | 4 | 20 y | 
| Safe operating mode selector switch | PL e | 3 | 4.1x10-8 | 4 | 20 y | 
| Evaluating safety signals | PL e | 3 | 4.1x10-8 | 4 | 20 y | 
| Applies to all additionally included safety functions such as emergency stop, enabling switch, etc. | |||||
| B10D | Mission time | |
|---|---|---|
| Emergency stop | 0.13x106 | 20 y | 
Miscellaneous
| Product version number | V3.30.10 | 
Interface
| Bus data protocol | Profinet (IEC 61158 type 10) | 
| Safety data protocol | Profisafe (IEC 61784-3-3) | 
| Date interface | Ethernet | 
Accessories
				
				ZSA
				
				
				
				
					
							ZSA, 3-stage, with cable and plug connector RC12
					
					
					
					
		
		
			 
			
					
				
		
		
			 
			
					
				
		
		
			 
			
					
				
		
		
			 
			
					
				

				092141
ZSA092141C2038
				ZSA092141C2038
- Housing G1
- 3-stage function
- Straight connecting cable with plug connector, 5 m
- Direct connection to safety switch

				097567
ZSA097567C2038
				ZSA097567C2038
- Housing G1
- 3-stage function
- Straight connecting cable with plug connector, 10 m
- Direct connection to safety switch

				099495
ZSA099495C2038
				ZSA099495C2038
- Housing G1
- 3-stage function
- Straight connecting cable with plug connector, 15 m
- Direct connection to safety switch

				100873
ZSA100873C2038
				ZSA100873C2038
- Housing G1
- 3-stage function
- Straight connecting cable with plug connector, 25 m
- Direct connection to safety switch
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
							Download Complete Package (ZIP, 6,1 MB)
						
Single Documents
				
				Declarations of conformity
				
				
				
				
					
						EU-Konformitätserklärung
					
					
					
					
					
						 
						
Doc. no.
Version
Language
Size

EU-Konformitätserklärung
Doc. no.
										EDC2123624
Version
										Language
										Size
										0,2 MB
					
						UKCA-Konformitätserklärung
					
					
					
					
					
						 
						
Doc. no.
Version
Language
Size

UKCA-Konformitätserklärung
Doc. no.
										EDC20001506
Version
										Language
										Size
										0,1 MB
				
				Instructions
				
				
				
				
					
						Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Data Structure Type A
					
					
					
					
					
						 
						
					
						 
						
Doc. no.
Version
Language
Size

Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Data Structure Type A
Doc. no.
										2114575
Version
										03/24
Language
										Size
										3,4 MB

Betriebsanleitung Sicherheitssysteme MGB-L..B-PN.-… (PROFINET) und mit Datenstruktur Typ A
Doc. no.
										2114575
Version
										03/24
Language
										Size
										3,4 MB
Other Documents
				
				Application examples
				
				
				
				Approvals and certificates
				
				
				
				
					
						FCC
					
					
					
					
					
						 
						
Doc. no.
Version
Language
Size

FCC
Doc. no.
										20001708
Version
										Language
										Size
										0,1 MB
					
						Profisafe
					
					
					
					
					
						 
						
Doc. no.
Version
Language
Size

Profisafe
Doc. no.
										Version
										Language
										Size
										0,2 MB
					
						TUEV Süd München
					
					
					
					
					
						 
						
Doc. no.
Version
Language
Size

TUEV Süd München
Doc. no.
										Version
										Language
										Size
										0,4 MB
					
						WEEE
					
					
					
					
					
						 
						
Doc. no.
Version
Language
Size

WEEE
Doc. no.
										ECO20001806
Version
										Language
										Size
										0,1 MB
					
						c UL us
					
					
					
					
					
						 
						
Doc. no.
Version
Language
Size

c UL us
Doc. no.
										Version
										Language
										Size
										0,7 MB
Ordering data
| Ordernumber | 114778 | 
| Item designation | MGB-L2CB-PNC-R-114778 | 
| Gross weight | 4,54kg | 
| Customs tariff number | 85371098 | 
| ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking | 
 
				