EUCHNER – More than safety.
EUCHNER – More than safety.

CES-I-AP-M-C04-USI-117323 (Order no. 117323)

Non-contact safety switches CES-I-AP-.-C04-, M12; pin 5 not used

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4 / PL e according to EN ISO 13849-1
  • Three active faces
  • Connecting cable PUR, 0.1 m, plug connector M12, 5-pin; pin 5 not used
  • Multicode
CES-I-AP-M-C04-USI-117323 (Order no. 117323)

Description

Installation position

Permissible installation position

Multicode evaluation

Every suitable actuator is detected by the switch.

Category according to EN 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4/PL e according to EN 13849-1

Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated.

LED indicator

STATE

Status LED

DIA

Diagnostics LED

Connector assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1UBPower supply, DC 24 VBN
2FO1ASafety output, channel 1WH
30VGround, DC 0 VBU
4FO1BSafety output, channel 2BK
5-n.c.GY
Dimension drawing
Dimension drawing
Wiring drawing<br>Wiring diagram
Wiring drawing
Wiring diagram
CES-C04: Transponder-coded safety switch

Dimension drawings

Dimension drawings
1Active face
2LED status indication
3With rubber support

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E346349_1/1ECOLAB__

Work area

Repeat accuracy R
according to EN 60947-5-2 <= 10

Electrical connection ratings

Current consumption
no load on outputs max. 35 mA
Fusing
external (operating voltage) 0.25 ... 8 A
Rated insulation voltage Ui 300 V
Rated impulse withstand voltage Uimp 1.5 kV
Operating voltage DC
UB 24 V DC -15% ... +15% regulated, residual ripple < 5%, PELV (The device tolerates voltage interruptions in the operating voltage, e.g. test pulses, of up to 5 ms. These voltage interruptions are also output on the outputs.)
Turn-on time
Safety outputs max. 300 ms
EMC protection requirements according to EN IEC 60947-5-3
Risk time according to EN 60947-5-3 max. 260 ms
Safety class III
Degree of contamination (external, according to EN 60947-1) 3
Safety outputs FO1A / FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
rated conditional short-circuit current 100 A
Discrepancy time max. 10 ms
Output voltage
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
HIGH U(FO1A) / U(FO1B) UB-1.5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.)
Switching current
per safety output 1 ... 150 mA
Utilization category
DC-13 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
Off-state current Ir max. 0.25 mA
Test pulses max. 0.3 ms (Applies to a load with C <= 30 nF and R <= 20 kohm)
Test pulse interval min. 100 ms

Mechanical values and environment

Connection PUR cable, 100mm, with plug connector M12x1, 5-pin; pin 5 not used
Degree of protection IP67
Ready delay 0.5 s
Material
Housing Plastic, PBT
Rubber support NBR 80 ±5 Shore
Dynamic bending radius 10 x cable diameter
Static bending radius 5 x cable diameter
Installation orientation any
Switching frequency max. 1 Hz
Tightening torque
Fixing screws max. 0.8 Nm
Mounting distance
between 2 switches or 2 actuators min. 80 mm
Mounting type Surface mounting on metal
Shock and vibration resistance according to EN IEC 60947-5-3
Cable ambient temperature (dynamic) -25 ... +65 °C
Cable ambient temperature (static) -25 ... +65 °C

Reliability values acc. to EN ISO 13849-1

Mission time 20 y
Monitoring of the guard position
Category 4
Performance Level PL e
PFHD 4.1 x 10-9

Miscellaneous

Additional feature Rubber support included
The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures

In combination with actuator CES-A-BDN-06-104730

Assured operating distances sao
Installation position A or B (front side) min. 14 mm
Installation position C or D (broad side) min. 10 mm
Assured release distance sar
in x/z direction max. 40 mm
in y direction max. 60 mm
Operating distance
Installation position C or D (broad side) 15 mm
Installation position A or B (front side) 19 mm
Switching hysteresis 1 ... 2 mm

In combination with actuator CES-A-BBN-C04-115271, CES-A-BBN-C04-EX-137527

Assured operating distances sao
Installation position A or B (front side) min. 10 mm
Installation position C or D (broad side) min. 6 mm
Assured release distance sar
in y direction max. 60 mm
in x/z direction max. 40 mm
Operating distance
Installation position A or B (front side) 15 mm
Installation position C or D (broad side) 11 mm
Switching hysteresis 1 ... 2 mm

In combination with actuator CES-A-BBN-161502

Assured operating distances sao
in z direction / installation position A + B min. 15 mm
in x direction/installation position C + D min. 10 mm
Assured release distance sar
in y direction / installation position C + D max. 72 mm
in x/z direction / installation position C + D max. 63 mm
in y direction / installation position A + B max. 77 mm
in x/z direction / installation position A + B max. 69 mm
Operating distance
Installation position A + B 30 mm
Installation position C + D 25 mm
Switching hysteresis
in x direction/installation position C + D 1 ... 2 mm
in z direction / installation position A + B 1 ... 2 mm

In combination with actuator CES-A-BDN-06-161742

Assured operating distances sao
Installation position A min. 16 mm
Installation position C min. 10 mm
Assured release distance sar
Installation position C max. 72 mm
Installation position A max. 77 mm
Operating distance
Installation position C 23 mm
Installation position A 26 mm
Switching hysteresis 1 ... 2 mm

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 7,1 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 117323
Item designation CES-I-AP-M-C04-USI-117323
Gross weight 0,081kg
Customs tariff number 85365019

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com