CET3-AP-CRA-CH-50X-SA-121579 (Order no. 121579)

Non-contact safety switch CET-AP-..., M12

  • Safety switch with guard locking and integrated evaluation electronics
  • Locking force up to 6,500 N
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4 / PL e according to EN ISO 13849-1
  • With 1 plug connector M12, 8-pin
  • Multicode
  • Door monitoring output
  • Indication of the door position by LED
  • Approach direction A (delivery state)
CET3-AP-CRA-CH-50X-SA-121579 (Order no. 121579)

Description

Approach direction

Horizontal

Can be adjusted in 90° steps

Safety switch

The device may be operated only in conjunction with the actuator CET-A-....

Important: The actuator must be ordered separately.

Multicode evaluation

Every suitable actuator is detected by the switch.

Solenoid operating voltage

  • DC 24 V +10%, -15%

Guard locking type

CET3

Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. The door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). The output OUT D also remains set when guard locking is active.

LED function display

State LED

Status LED

DIA LED

Diagnostics LED

LED 1 rd

illuminates when the solenoid is energized

LED 2 gn

illuminates when door is closed

Additional connections

OUT

Monitoring output (semiconductor)

OUT D

Door monitoring output

RST

Reset input

Category according to EN ISO 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4 / PL e according to EN ISO 13849-1
  • The stated safety characteristics apply to any installation orientations of the safety switch.

Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must always be evaluated.

Dimension drawing
Dimension drawing
Wiring drawing<br>Connector assignment
Wiring drawing
Connector assignment
Wiring drawing<br>Block diagram
Wiring drawing
Block diagram
CET3-AP: Mounting emergency release safety swith CET3-AP
CET: Transponder-coded safety switch with guard locking
CET3-AP: Mounting and Setup CET3-AP (closed-circuit current principle)
CET3-AP: Mounting auxiliary release with key CET3-AP

Dimension drawings

Dimension drawings

Connection examples

Connection examples

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/8DGUV_ET 20018_ET 20019

Work area

Repeat accuracy R
according to EN 60947-5-2 10 %

Electrical connection ratings

Connecting cable 30V DC, 2A (for UL requirement UL category code (CYJV/CYJV7))
Current consumption
IB 80 mA
ICM 450 mA
Fusing
external (solenoid operating voltage UCM) 0.5 ... 8 A
external (operating voltage UB) 0.25 ... 8 A
Operating voltage DC
UB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple < 5%, PELV (The device tolerates voltage interruptions of up to 5 ms)
LED 24 V DC -15% V DC ... +10% V DC
EMC protection requirements according to EN IEC 60947-5-3
Power consumption
Solenoid 11 W
Safety class
EN IEC 61140 III
Solenoid duty cycle 100 %
Utilization category
DC-13 24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Solenoid operating voltage DC
UCM 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple < 5%, PELV
Switching load
according to UL 24V DC, Class 2 (For alternatives, see operating instructions)
Test pulses max. 0.3 ms (Applies to a load with C <= 30 nF and R <= 20 kohm)
Degree of contamination (external, according to EN 60947-1) 3
Monitoring output OUT D
Output type p-switching, short circuit-proof
Output voltage
OUT D 0.8xUB ... UB V DC
Switching current
OUT D 1 ... 50 mA
Switching delay from state change max. 700 ms
Monitoring output OUT
Output type p-switching, short circuit-proof
Output voltage
OUT 0.8xUB ... UB V DC
Switching current
OUT 1 ... 50 mA
Switching delay from state change max. 400 ms
Safety outputs OA / OB
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Discrepancy time
both safety outputs max. 10 ms
Off-state current Ir max. 0.25 mA
Output voltage
HIGH U(OA,OB) UB-1.5V ... UB V DC
LOW U(OA,OB) 0 ... 1 V DC
Risk time according to EN 60947-5-3
Single device max. 400 ms
Switching current
je Sicherheitsausgang OA / OB 1 ... 200 mA
Turn-on time 400 ms

Mechanical values and environment

Ambient temperature
at UB = 24V DC -20 ... +55 °C
Approach speed max. 20 m/min
Connection 1 plug connector M12, 8-pin
Degree of protection IP67 (screwed tight plug connector/mating component)
Guard locking principle Closed-circuit current principle
Installation orientation any (preferably head downward)
Locking force Fmax 6500 N
Material
Ramp stainless steel
Safety switch housing Die-cast aluminum
Mechanical life 2 x 10⁶
Ready delay 1 s
Degree of freedom X ±5 mm
Degree of freedom Y ±5 mm
Degree of freedom Z ±4 mm
Switching frequency max. 0.5 Hz
Shock and vibration resistance according to EN 60947-5-3
Locking force FZh 5000 N (FZH = FMAX/1.3)

Reliability values according to EN ISO 13849-1

Mission time 20 y
Control of guard locking
Category Depending on external control of guard locking
Performance Level Depending on external control of guard locking
PFHD Depending on external control of guard locking
Monitoring of guard locking and the guard position
Performance Level PL e
Category
Any installation orientation 4
PFHD
Any installation orientation 3.1 x 10-9

Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures; see operating instructions

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 8,5 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 121579
Item designation CET3-AP-CRA-CH-50X-SA-121579
Gross weight 1,267kg
Customs tariff number 85365019