ZSA, 3-stage with cable
- Housing G1
- 3-stage function
- Straight connecting cable, 5 m

Ismertetés
Switching element
220 | 2 NO + 2 NC ![]() |
Cable
The high-quality connecting cables (individual screening of the safety contacts) are available in a straight version.
3-stage function
Enabling function is active only in the second stage (middle position, actuating point). If the pushbutton is released or pushed further (panic function), the enabling is removed (dependent on the wiring, see function sequence).



Dimension drawing

1 | Cable end sleeves |
220

Travel diagram

![]() | open |
![]() | closed |
![]() | closed, enabling |
Műszaki adatok
Engedélyezések




Mechanikai értékek és környezet
Material | Plastic |
Weight | |
Net | 1,5 kg |
Ambient temperature | -5 ... 50 °C |
Degree of protection | IP67 |
Mechanical life | |
Position 1-2-1 | 0,1 x 106 |
Position 1-2-3-1 | 0,1 x 106 |
Switching principle | Slow-action contact element |
Number of positively driven contacts | 2 |
Number of NO contacts | 2 |
Connection | Flying lead |
Cable length | |
straight | 5 m |
Elektromos csatlakoztatási értékek
Rated conditional short-circuit current | 100 A |
Utilization category acc. to EN 60947-5-1 | |
AC-15 | 2A 230V |
DC-13 | 2A 24V |
Short circuit protection according to IEC 60269-1 | 2A gG (In case of operating voltages other than 24 V, the short circuit protection must be dimensioned accordingly and checked.) |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2,5 kV |
Switching voltage | |
Min. at 10mA | 12 V |
Switching current | |
Min. at 24V | 1 mA |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | 8x0.34mm² (4x0.34mm² screened + 4x0.34mm² unscreened) |
Switching characteristics | 3-stage enabling switch |
Egyebek
In compliance with | 60947-5-8 |
Megbízhatósági értékek az EN ISO 13849-1 szerint
Enabling switch | |
B10D | 0,5 x 106 |