Plug connector and connection set for extending the connection cable for read heads CES-A-L.../CEM-A-L...
- Plug connector for extending the connecting cable
- For read heads CES-A-L.../CEM-A-L...

Ismertetés
Using EUCHNER couplings / plug connectors, the user can cut the read head cable to size on site at any point and connect the couplings / plug connectors.
Notice
The connecting cable for the read head can be extended using only these self-assembly couplings / plug connectors under the following conditions:
- The total maximum cable length is 25 m, taking into account the operating distance
- The cable specified by EUCHNER must be used for the extension (screened, strand cross-section 2 x 0.25 mm²)
- The plug connector housing must be electrically isolated from the machine ground


Dimension drawing

Dimension drawing

Műszaki adatok
Mechanikai értékek és környezet
Housing material | |
Housing | Brass, matt chromium plated |
Ambient temperature | -20 ... 80 °C |
Degree of protection | IP65 (In the inserted and locked state) |
Contact material | Brass, nickel-plated, 1μm hard gold-plated |
Number of pins | 3 + PE |
Clamping range for cable | 4 ... 6 mm |
Elektromos csatlakoztatási értékek
Nominal current | 6 A |
Rated voltage | 250 V |
Rated impulse withstand voltage Uimp | 4 kV |
Connection cross-section | max.1 mm² (Soldered connection) |
Contact resistance | 5 mΩ |
Letöltések
Catalogs
Transponder-coded safety systems with external evaluation
Dok. sz.
Változat
Nyelv
Méret

Transponder-coded safety systems with external evaluation
Dok. sz.
127597
Változat
02-01/18
Nyelv
Méret
3,0 MB

Systèmes de sécurité à codage par transpondeur avec analyse externe
Dok. sz.
137968
Változat
02-01/18
Nyelv
Méret
3,0 MB

Sistemas de seguridad con codificación por transponder y evaluación externa
Dok. sz.
139969
Változat
02-01/18
Nyelv
Méret
3,0 MB

Transpondercodierte Sicherheitssysteme mit externer Auswertung
Dok. sz.
127596
Változat
02-01/18
Nyelv
Méret
3,0 MB