EUCHNER – More than safety.
EUCHNER – More than safety.
KezdőlapProductsRGBF05R12-502-M

RGBF05R12-502-M (Rend. sz. 082321)

Series RGBF... 12 mm mechanical

  • Plunger spacing 12 mm
  • Upright housing according to DIN 43697
  • Degree of protection IP67 according to IEC 60529
RGBF05R12-502-M (Rend. sz. 082321)

Ismertetés

Switching element

ES 502 ESnap-action switching contact 1 NC + 1 NO

On the usage of safety switching elements, the dog distance must be maintained to achieve the positively driven travel. The dogs must be positively mounted according to EN 1088, i.e. riveted, welded or secured in some other way against becoming loose.

    Dimension drawing
    Dimension drawing
    Wiring diagram
    Wiring diagram

    Dimension drawing

    Dimension drawing
    1Operating point
    2Free position
    3Groove for sealing ring
    4Number of plungers

    Wiring diagram

    Wiring diagram

    Műszaki adatok

    Engedélyezések

    Zulassung EAC

    Mechanikai értékek és környezet

    Design Upright, according to DIN 43697
    Housing material
    Housing Die-cast aluminum, anodized
    Weight
    Net 1,1 kg
    Ambient temperature -5 ... 80 °C
    Degree of protection IP67
    Mechanical life 30 x 106
    Contact material Silver alloy, gold flashed
    Switching principle Snap-action switching contact (Contact closing time < 4 contact bounce time < 3)
    Plunger spacing 12 mm
    Installation orientation Any
    Number of switching elements 5
    Number of NC contacts 5
    Number of NO contacts 5
    Connection
    4 x M25 x 1.5
    Approach speed 0,01 ... 80 m/min
    Actuating element
    Plain bearing Roller plunger (Operating point accuracy ± 0.01. The reproducible switching point accuracy refers to the axial travel of the plunger after the switching element ES 502 E has been run-in with approx. 2000 operating cycles.)
    Actuating force min.20 N

    Elektromos csatlakoztatási értékek

    Thermal rated current Ith 8 A
    Utilization category acc. to EN 60947-5-1
    AC-15 6A 230V
    DC-13 6A 24V
    AC-12 8 A, 250 V
    Short circuit protection according to IEC 60269-1 8A gG
    Rated insulation voltage Ui 250 V
    Rated impulse withstand voltage Uimp 2,5 kV
    Switching current
    Min. at DC 12V min.10 mA
    Connection cross-section 0,34 ... 1,5 mm²

    Műszaki támogatás

    Műszaki támogatás
    Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

    EUCHNER Magyarország Kft.
    +36 1919 0855
    info(at)euchner.hu