RGBF02D16-514-M (Rend. sz. 082339)

Series RGBF... 16 mm mechanical

  • Plunger spacing 16 mm
  • Upright housing according to DIN 43697
  • Degree of protection IP67 according to IEC 60529
RGBF02D16-514-M (Rend. sz. 082339)

Ismertetés

Switching element

ES 514Snap-action switching contact 1 NC + 1 NO

On the usage of safety switching elements, the dog distance must be maintained to achieve the positively driven travel. The dogs must be positively mounted according to EN ISO 14119, i.e. riveted, welded or secured in some other way against becoming loose.

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimension drawing

Dimension drawing
1Operating point
2Free position
3Safety switching element ES 514 positive opening. Positive opening function is dependent on maintaining this distance. Actuators (dogs) must be connected to the machine in a flush position. Switch can be replaced only with the same type.
4Groove with sealing ring
5Pressure sensitive label 041734 applied.
6Number of plungers

Wiring diagram

Wiring diagram

Műszaki adatok

Engedélyezések

Zulassung EACZulassung c_UL_us LISTED Class 2

Mechanikai értékek és környezet

Design Upright, according to DIN 43697
Housing material
Housing Die-cast aluminum, anodized
Weight
Net 0,85 kg
Ambient temperature -5 ... 80 °C
Degree of protection IP67
Mechanical life 1 x 106
Contact material Silver alloy, gold flashed
Switching principle Snap-action switching contact (Contact closing time <5 contact bounce time <3 ms)
Plunger spacing 16 mm
Installation orientation Any
Number of switching elements 2
Number of positively driven contacts 2
Number of NO contacts 2
Connection
4 x M25 x 1.5
Approach speed 0,01 ... 40 m/min
Actuating element Chisel plunger
Actuating force min.30 N

Elektromos csatlakoztatási értékek

Thermal rated current Ith 10 A
Utilization category acc. to EN 60947-5-1
AC-15 2.5A 230V
DC-13 6A 24V
Short circuit protection according to IEC 60269-1 6A gG
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 4 kV
Switching current
Min. at DC 24V min.5 mA
Connection cross-section 0,34 ... 1,5 mm²

Megbízhatósági értékek az EN ISO 13849-1 szerint

B10D 2 x 106