Evaluation unit CES-A-ABA.../CES-A-UBA... (for 1 read head)

  • 1 read head can be connected
  • 2 safety contacts (relay contacts)
  • 1 internal normally open contact per safety contact
  • Unicode evaluation unit
  • Category 3 / PL e according to EN ISO 13849-1

Ismertetés

Unicode evaluation unit

Each actuator is highly coded (unicode). The evaluation unit detects only actuators that have been taught-in. Max. 8 actuators can be taught-in.

Only the last actuator taught-in is detected.

Category according to EN ISO 13849-1

Due to two redundant relay outputs (safety outputs) with internally monitored contacts, suitable for:

  • Category 3 / PL e according to EN ISO 13849-1

To achieve the stated category, both safety contacts must always be evaluated.

Actuating range

The standard version of the evaluation unit (CES-A-…-01B) has a large actuating range that, e.g., permits larger tolerances in the alignment of read head and actuator. Wherever a smaller actuating range is required, the version with reduced actuating range (CES-A-…-01) can be used.

TST

Input for self-test

OUT

Monitoring output (semiconductor)

ERR

Diagnostic output

GND

Connected internally to 0V (not for high currents)

Dimension drawing
Dimension drawing
Wiring drawing<br>Block diagram
Wiring drawing
Block diagram

Dimension drawings

Dimension drawings
1suitable for 35 mm mounting rail according to EN 60715

Connection examples

Connection examples

Műszaki adatok

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/1DGUV_ET 20018_ET 20019CCC_2020980305000537_CQC2014010303679509

Work area

Repeat accuracy R
according to EN 60947-5-2 max. 10 %

Controls and indicators

LED indicator
Safety output status
Status LED
Diagnostics LED

Electrical connection ratings

Connection cross-section
(screw terminals) 0.25 ... 2.5 mm²
Current consumption
(with relay energized) 150 mA (without taking into account the load currents at the monitoring outputs)
Fusing
external (operating voltage UB) 0.25 ... 8 A
Operating voltage DC
UB 21 ... 24 ... 27 V DC regulated, residual ripple < 5%
EMC protection requirements according to EN 60947-5-3
Degree of contamination (external, according to EN 60947-1) 2
Input: test input TST
Input voltage
HIGH 15 ... UB V DC
LOW 0 ... 2 V DC
Monitoring outputs: diagnostics ERR, door monitoring output OUT
Output type Semiconductor output, p-switching, not short circuit-proof
Output current max. 20 mA
Output voltage 0.8 x UB ... UB V DC
Safety contacts 13/14, 23/24
Output type Relay contacts, floating
Fusing
external (safety circuit) according to EN 60269-1 6 AgG or 6 A circuit breaker (characteristic B or C)
rated conditional short-circuit current 100 A
Rated insulation voltage Ui 63 V
Rated impulse withstand voltage Uimp 1.5 kV
Discrepancy time
(between the operating points of both relays) max. 120 ms
Switching current
at switching voltage AC/DC 21 ... 60 V 1 ... 300 mA
at switching voltage AC/DC 10 ... 30 V 10 ... 6000 mA
Utilization category
DC-12 30 V 6 A
DC-12 60 V 0.3 A
AC-12 60 V 0.3 A
DC-14 30 V 2 A
DC-13 24 V 3 A
AC-12 30 V 6 A
Switching load
according to c UL us Class 2 max. 30 V AC / Class 2 max. 60 V DC; 120 V AC 3 A / 240 V AC 1.5 A

Mechanical values and environment

Number of read heads 1 read head can be connected
Connection plug-in screw terminals, coded
Degree of protection IP20
Ready delay max. 3 s (After the operating voltage is switched on, the relay outputs are switched off and the door monitoring contact is set to LOW level during the ready delay.)
Material
Housing Plastic PA6.6
Switching frequency max. 1 Hz (If the current load is >100 mA, a switching frequency of 0.1 Hz should not be exceeded as this will affect the mechanical life of the relay contacts.)
Reaction time
after change in the actuation status max. 180 ms (Corresponds to the risk time according to EN 60947-5-3. This is the maximum OFF time for the safety outputs following removal of an actuator.)
Atmospheric humidity
not condensing max. 80 % rH
Mounting distance
laterally to the neighboring device min. 10 mm (If several evaluation units are mounted side by side in a control cabinet without air circulation (e.g. fan), a minimum distance of 10 mm must be maintained between the evaluation units. This distance enables the heat from the evaluation unit to dissipate.)
Mounting type Mounting rail 35 mm according to DIN EN 60715 TH35
Ambient temperature
at UB = 24V DC -20 ... +55 °C
Dwell time min. 0.5 s (The dwell time of an actuator inside and outside the actuating range must be at least 0.5 s to ensure safe detection of internal faults in the evaluation unit (self-monitoring).)
Safety contacts 13/14, 23/24
Number of safety contacts 2 Relay with internally monitored contacts (to ensure safety, both safety outputs (13/14 and 23/24) must always be evaluated)
Mechanical life
Operating cycles (relay) 10 x 10⁶

Reliability values acc. to EN ISO 13849-1

Diagnostic Coverage (DC) 90 %
Number of switching cycles
≤ 0.1 A at 24 V DC max. 760000 1/y
≤ 1 A at 24 V DC max. 153000 1/y
≤ 3 A at 24 V DC max. 34600 1/y
Mission time 20 y (This value is dependent on the number of switching cycles and the switching current.)
Monitoring of the guard position
Category 3 (This value is dependent on the number of switching cycles and the switching current.)
Performance Level PL e (This value is dependent on the number of switching cycles and the switching current.)
PFHD 4.3 x 10-8 (This value is dependent on the number of switching cycles and the switching current.)

Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measure.

In combination with read head CES-A-LQA-SC and actuator CES-A-BBA-071840, CES-A-BCA

Assured operating distances sao
for vertical approach direction (center offset m=0) min. 10 mm (These values apply to surface installation of the read head and the actuator.)
for side approach direction (distance in x direction 8 mm) min. +/- 18 mm (These values apply to surface installation of the read head and the actuator.)
Assured release distance sar max. 47 mm
Operating distance
for side approach direction (distance in x direction 8 mm) +/- 22 mm (These values apply to surface installation of the read head and the actuator.)
for vertical approach direction (center offset m=0) 15 mm (These values apply to surface installation of the read head and the actuator.)
Switching hysteresis
for vertical approach direction 2 ... 3 mm (These values apply to surface installation of the read head and the actuator.)
for side approach direction (distance in x direction 8 mm) 1 ... 1.8 mm (These values apply to surface installation of the read head and the actuator.)

In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V

Mounting distance
neighboring read heads min. 50 mm (If several evaluation units are mounted side by side in a control cabinet without air circulation (e.g. fan), a minimum distance of 10 mm must be maintained between the evaluation units. This distance enables the heat from the evaluation unit to dissipate.)

In combination with read head CES-A-LQA-SC

Mounting distance
neighboring read heads min. 80 mm (If several evaluation units are mounted side by side in a control cabinet without air circulation (e.g. fan), a minimum distance of 10 mm must be maintained between the evaluation units. This distance enables the heat from the evaluation unit to dissipate.)

In combination with read head CES-A-LMN-SC

Mounting distance
neighboring read heads min. 20 mm (If several evaluation units are mounted side by side in a control cabinet without air circulation (e.g. fan), a minimum distance of 10 mm must be maintained between the evaluation units. This distance enables the heat from the evaluation unit to dissipate.)

In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BDA-20

Actuator distance s
Minimum distance for side approach direction min. 4 mm (on mounting in non-metallic environment)
Assured operating distances sao
with center offset m=0 min. 11 mm (on mounting in non-metallic environment)
Assured release distance sar max. 33 mm
Operating distance
with center offset m=0 16 mm (on mounting in non-metallic environment)
Switching hysteresis 0.5 ... 2 mm (on mounting in non-metallic environment)

In combination with read head CES-A-LQA-SC and actuator CES-A-BQA

Assured operating distances sao
for vertical approach direction (center offset m=0) min. 16 mm (These values apply to surface installation of the read head and the actuator.)
for side approach direction (distance in x direction 10 mm) min. +/- 24 mm (These values apply to surface installation of the read head and the actuator.)
Assured release distance sar max. 60 mm
Operating distance
for side approach direction (distance in x direction 10 mm) +/- 28 mm (These values apply to surface installation of the read head and the actuator.)
for vertical approach direction (center offset m=0) 23 mm (These values apply to surface installation of the read head and the actuator.)
Switching hysteresis
for vertical approach direction 2 ... 3 mm (These values apply to surface installation of the read head and the actuator.)
for side approach direction (distance in x direction 10 mm) 1 ... 1.3 mm (These values apply to surface installation of the read head and the actuator.)

In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BBA-071840, CES-A-BCA

Actuator distance s
Minimum distance for side approach direction min. 3 mm
Assured operating distances sao
with center offset m=0 min. 10 mm (These values apply to surface installation of the read head and the actuator.)
Assured release distance sar max. 32 mm
Operating distance
with center offset m=0 15 mm (These values apply to surface installation of the read head and the actuator.)
Switching hysteresis 0.5 ... 2 mm (These values apply to surface installation of the read head and the actuator.)

In combination with read head CES-A-LMN-SC and actuator CES-A-BMB

Actuator distance s
Minimum distance min. 1.2 mm
Assured operating distances sao
with center offset m=0 min. 3.5 mm (These values apply to surface installation of the read head in steel.)
Assured release distance sar max. 10 mm
Operating distance
with center offset m=0 5 mm (These values apply to surface installation of the read head in steel.)
Switching hysteresis 0.1 ... 0.3 mm (These values apply to surface installation of the read head in steel.)

Tartozékok

Letöltések

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download complete package (ZIP, 4,2 MB)

Single Documents

Other Documents

Ordering data

Rend. sz. 083513
Articlename CES-A-ABA-01B
Weight 0,247kg
GTIN 4047048000810
Customsclass 85364110