EUCHNER – More than safety.
EUCHNER – More than safety.

CMS-R-AXF-03V (Rend. sz. 084585)

Read heads CMS, design A - with NO contact combinations, PVC

  • In combination with evaluation unit CMS-E-AR
  • Cube-shaped version, 88 x 25 mm
  • NO contacts wired in series
  • Connecting cable
  • Cable type: PVC
CMS-R-AXF-03V (Rend. sz. 084585)

Ismertetés

Alignment of read head and actuator

Operating diagram, design A

CMS-R-AXF

<p>CMS-R-AXF</p>
  • typ. operating distance
  • typ. release distance
Dimension drawing
Dimension drawing
CMS-R-BXP
CMS-R-BXP

Dimension drawings

Dimension drawings

Connection examples

Connection examples

Műszaki adatok

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_5/1

Work area

Assured operating distances sao
with center offset m=0 min. 6 mm (Value applies only if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
Assured release distance sar max. 18 mm (The assured release distance s_ar corresponds to the reset distance.)
Repeat accuracy R max. 10 %

Electrical connection ratings

Rated insulation voltage Ui 26.4 V
Rated impulse withstand voltage Uimp 1.5 kV
Switching current 8 ... 500 mA
Switching voltage
DC 24 V
Switching voltage according to UL
according to UL Class 2 max. 24 V DC
Switching characteristics parallel
Degree of contamination (external, according to EN 60947-1) 2

Mechanical values and environment

Number of NO contacts 3 NO contacts
Connection hard-wired encapsulated cable with cable end sleeves 0.75mm2
Degree of protection IP67
Design A
Material
Housing Fiber glass reinforced PPS
Cable material PVC
Mechanical life 100 x 10⁶
Installation orientation any (During mounting it must be ensured that the marking arrows on the actuator and the read head are opposite each other.)
Tightening torque 0.4 ... 0.5 Nm
Cable length 3 m
Shock and vibration resistance according to EN IEC 60947-5-3
Ambient temperature -20 ... +60 °C
Method of operation magnetic, reed contact

Miscellaneous

in compliance with EN ISO 13849-1:2015; EN 50178:1997; EN 60204-1:2006/A1:2009; EN ISO 14119:2013; EN 61000-6-2:2005; EN 61000-6-3:2007/A1:2011; EN 60947-5-3:2013

Letöltések

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download complete package (ZIP, 2,2 MB)

Single Documents

Other Documents

Ordering data

Rend. sz. 084585
Articlename CMS-R-AXF-03V
Weight 0,183kg
Customsclass 85389099

Műszaki támogatás

Műszaki támogatás
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER Magyarország Kft.
+36 1919 0855
info(at)euchner.hu