Basic device ESM-BA2.., 2 safety contacts, cat. 4
- ESM-BA.. Use up to category 4 according to EN ISO 13849-1
- LED status indicators
- 1-channel or 2-channel control
- 2 redundant safety contacts
- Short circuit and earth fault/ground fault monitoring

Ismertetés
Relay outputs
The outputs are electrically decoupled and of redundant design.
Connection options
By using suitable wiring, the following functions can be selected:
- Relay start with automatic start or a start button
- Monitoring of downstream relays or contactors.
- Simultaneity monitoring to monitor safety components over time
- Relay start using a monitored start button
- Short circuit monitoring to detect short circuits between the connecting cables and to shut down the outputs or prevent relay starting if necessary
- Earth fault/ground fault monitoring to detect short circuits between a connecting cable and earth or ground and to shut down the outputs or prevent relay starting if necessary.
Connection terminals
Optionally, the ESM-BA... devices are also available as versions with plug-in connection terminals.


Dimension drawings

ESM-BA2... |
Connection examples

Műszaki adatok
Engedélyezések



Mechanikai értékek és környezet
Housing material | |
Housing | Polyamide PA6.6 |
Weight | |
Net | 0,23 kg |
Ambient temperature | |
At UB = 24V AC | -15 ... 40 °C |
At UB = 24V DC | -15 ... 60 °C (at 20% undervoltage T<sub>max</sub>: 50°C) |
Degree of protection | IP20 |
Mechanical life | |
operating cycles | 10 x 106 |
Contact material | AgSnO2 |
Mounting method | Mounting rail 35mm according to DIN EN 60715 TH35 |
Connection | Connection terminals |
Length of control cable | |
With conductor cross-section 0.75mm2 | 1000 m |
Safety contacts 13/14, 23/24 | |
Number of safety contacts | 2 |
Elektromos csatlakoztatási értékek
Operating voltage | |
AC/DC | 24 V -10% ... +10% (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.) |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | |
Leakage path/air gaps | 4 kV |
Overvoltage category according to IEC EN 60664-1 | 3 |
Reverse polarity protection | |
On version UB =24V DC | |
Connection rating | |
at 24V DC | 1,5 W |
Degree of contamination (external, according to EN 60947-1) | 2 |
Connection cross-section | 0,14 ... 2,5 mm² (Connection terminal (size)) |
Test voltage | |
Control system/contacts | 2,5 kV |
Control voltage | |
On S11 | 24 V 18,6 ... 26 V Start button |
Control current | |
S11...S14 | 40 mA |
LED indicator | 2 status displays (green) for relays K1 and K2 |
Safety contacts 13/14, 23/24 | |
Type of output | |
NO | Relay contacts, floating and positively driven (redundant) (Positively driven relay according to EN 50205) |
Switching voltage | |
AC | max.250 V |
DC | max.24 V |
Switching current | min.20 mA at 24V |
Fusing | |
External contact fuses (safety circuit) according to IEC 60269-1 | 10A gG |
Utilization category acc. to EN 60947-5-1 | |
AC-15 | 3A, 250V |
DC-13 | 3A, 24V |
AC-12 | 6A ohmic load, 250V (6 operating cycles/min.) |
DC-12 | 6A ohmic load, 24V (6 operating cycles/min.) |
Breaking capacity according to UL | 6A 250V AC / 2A 24V DC per contact |
Egyebek
In compliance with | EN ISO 13849-1: 2015; EN 62061: 2005 + AC: 2010 + A1: 2013 + A2: 2015; EN 50581: 2012 (RoHS) |
Megbízhatósági értékek az EN ISO 13849-1 szerint
Performance Level | PL e (This value is dependent on the number of switching cycles and the switching current.) |
Category | 4 (This value is dependent on the number of switching cycles and the switching current.) |
PFHD | 1.2 x 10-8 (This value is dependent on the number of switching cycles and the switching current.) |
Number of switching cycles | |
≤ 1 A at 24 V DC | max.100000 1/Jahr |
≤ 3 A at 24 V DC | max.22500 1/Jahr |
≤ 0.1 A at 24 V DC | max.400000 1/Jahr |
Mission time | 20 y (This value is dependent on the number of switching cycles and the switching current.) |
Letöltések
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Dok. sz.
Változat
Nyelv
Méret

EU-Konformitätserklärung
Dok. sz.
EDC2090791
Változat
Nyelv
Méret
0,2 MB
Other Documents
Application examples
Approvals and certificates
CCC
Dok. sz.
Változat
Nyelv
Méret

CCC
Dok. sz.
Változat
Nyelv
Méret
0,3 MB
TUEV Rheinland
Dok. sz.
Változat
Nyelv
Méret

TUEV Rheinland
Dok. sz.
Változat
Nyelv
Méret
0,7 MB
c UL us
Dok. sz.
Változat
Nyelv
Méret

c UL us
Dok. sz.
Változat
Nyelv
Méret
0,2 MB
Sales documentation
Interrupteurs de sécurité à codage magnétique CMS
Dok. sz.
Változat
Nyelv
Méret

Interrupteurs de sécurité à codage magnétique CMS
Dok. sz.
090606
Változat
10-11/20
Nyelv
Méret
5,8 MB
Magnetically Coded Safety Switches CMS
Dok. sz.
Változat
Nyelv
Méret

Magnetically Coded Safety Switches CMS
Dok. sz.
086824
Változat
10-11/20
Nyelv
Méret
5,7 MB
Ordering data
Rend. sz. | 085610 |
Articlename | ESM-BA201 |
Weight | 0,202kg |
Customsclass | 85364110 |
ECLASS | 27-37-18-19 Gerät zur Überwachung von sicherheitsgerichteten Stromkreisen |