EUCHNER – More than safety.
EUCHNER – More than safety.

GLBF04R12-1514-M (Rend. sz. 085943)

Series GLBF... 12 mm, mechanical

  • Plunger spacing 12 mm
  • Horizontal housing
  • Degree of protection IP67 according to IEC 60529
GLBF04R12-1514-M (Rend. sz. 085943)

Ismertetés

Switching elements

ES 502 E

Snap-action switching contact 1 NC + 1 NO

ES 514

Snap-action switching contact 1 NC + 1 NO

On the usage of safety switching elements, the dog distance must be maintained to achieve the positively driven travel. The dogs must be positively mounted according to EN ISO 14119, i.e. riveted, welded or secured in some other way against becoming loose.

Dimension drawing
Dimension drawing
(on request)
(on request)
ES 502 E
ES 502 E

Dimension drawings

Dimension drawings

Connection examples

Connection examples

Connection examples

Connection examples

Műszaki adatok

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/6CCC_2020980305000540_CQC2008010305306206

Electrical connection ratings

Connection cross-section 0.34 ... 1.5 mm²
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2.5 kV
Short circuit protection according to IEC 60269-1
8A gG (applies from station 2 with switching element ES502E)
6A gG (applies to station 1 with switching element ES514)
Switching current
min. at DC 12V min. 10 mA (applies from station 2 with switching element ES502E)
min. at DC 24V min. 5 mA (applies to station 1 with switching element ES514)
Utilization category
AC-15 6A 250V (applies from station 2 with switching element ES502E)
DC-13 6A 24V
AC-12 8A 250V
AC-15 2.5A 230V (applies to station 1 with switching element ES514)
rated thermal current Ith 8 A

Mechanical values and environment

Approach speed 0.01 ... 80 m/min
Number NC contacts 3
Number of switching elements 4
Number of NO contacts 4
Number of positively driven contacts 1
Connection
3 x M25 x 1.5
Degree of protection IP67
Design horizontal
Material
Housing Sand-cast aluminum, anodized
Contact Silver alloy, gold flashed
Actuating element
Slide bearing Roller plunger (Operating point accuracy ± 0.01. The reproducible operating point accuracy refers to the axial travel of the plunger after the switching element ES 502 E has been run-in with approx. 2,000 operating cycles.)
Actuating force min. 30 N
Mechanical life 1 x 10⁶
Installation orientation any
Switching principle
Snap-action switching contact (Contact closing time ≤ 5 ms, contact bounce time ≤ 3 ms, applies to station 1 with switching element ES514)
Snap-action switching contact (Contact closing time < 4 ms, contact bounce time < 3 ms; applies from station 2 with switching element ES502E)
Plunger spacing 12 mm
Ambient temperature -5 ... +80 °C

Reliability values acc. to EN ISO 13849-1

B10D 2 x 10⁶

Miscellaneous

Additional information Mixed contact assembly (On horizontal multiple limit switches, it is necessary to start with the safety station/s on the left side (view on the plunger side). If several safety stations are to be installed, these must be installed directly one after the other.)

Letöltések

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download complete package (ZIP, 1,4 MB)

Single Documents

Other Documents

Ordering data

Rend. sz. 085943
Articlename GLBF04R12-1514-M
Weight 0,95kg
Customsclass 85365019

Műszaki támogatás

Műszaki támogatás
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER Magyarország Kft.
+36 1919 0855