EUCHNER – More than safety.
EUCHNER – More than safety.

CIT3SX1R1G05KX (Rend. sz. 096560)

Read/write head CIT3 G05 with serial interface

  • Serial interface RS232
  • Active face can be adjusted to 5 different positions
  • Standard housing according to EN 50041
  • Connection terminals
CIT3SX1R1G05KX (Rend. sz. 096560)

Ismertetés

Serial interface

The individual commands for reading and writing the data carriers are in accordance with the common 3964R protocol and are described in the EUCHNER CIS3 system manual (order no. 071 652). For data carrier programming away from the installation, a convenient WINDOWS-compatible PC software application is available (Transponder Coding software, see page 41).

Standard housing

The size of the robust housing in degree of protection IP65 is compliant with the standard EN 50041. The division into 3 assemblies permits easy installation and straightforward replacement.

Mounting instructions

On mounting the read/write head and data carrier, it is to be ensured the crossing direction as per the direction of the arrow on the active face of the read/write head is observed.

Attention:

On the use of a screened cable, the connecting cable for the serial interface is allowed to be max. 5 m long.

Dimension drawing
Dimension drawing
Terminal assignment
Terminal assignment

Dimension drawings

Dimension drawings
1Active face
2Crossing direction
3LED status indication
4Shield spring
mCenter offset
sRead distance

Connection examples

Connection examples

Műszaki adatok

Engedélyezések

Richtlinie CE

Mechanikai értékek és környezet

Housing material
Housing Plastic
Ambient temperature 0 ... 55 °C
Degree of protection IP65
Connection Screw terminal
Cable length max.5 m RS232

Elektromos csatlakoztatási értékek

Operating voltage DC 20 ... 24 ... 28 V DC (All the electrical connections must either be isolated from the mains supply by a safety transformer according to IEC/EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.)
Current consumption max.140 mA
LED indicator
Green Operational
Yellow Data carrier in operating distance

Interfész, buszrendszer

Data interface RS232
Data protocol 3964R via RS232 8 data bits, even parity
Data rate 9,6 kbit/s

In combination with Data carrier CIS3P16D08KH16YSNOU, CIS3P16D08KH16YSNOP

Actuating range

Read distance 0 ... 5 ... 14 mm
Center offset
At 25°C, read distance s=5mm, in X direction -10 ... 10 mm
At 25°C, read distance s=5mm, in Y direction -6 ... 6 mm
Write distance
At 25°C 0 ... 5 ... 9 mm

In combination with Data carrier CIS3P35X16SH16YHNOP, CIS3P35X16SH16YHNOU, CIS3P35X16SH16YVNOP, CIS3P35X16SH16YVNOU

Actuating range

Read distance
At 25°C 0 ... 7 ... 18 mm
Center offset
At 25°C, read distance s=5mm, in X direction -10 ... 10 mm
At 25°C, read distance s=5mm, in Y direction -8 ... 8 mm
Write distance
At 25°C 0 ... 5 ... 10 mm

Letöltések

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download complete package (ZIP, 2,2 MB)

Single Documents

Other Documents

Ordering data

Rend. sz. 096560
Articlename CIT3SX1R1G05KX
Weight 0,372kg
Customsclass 85389099

Műszaki támogatás

Műszaki támogatás
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER Magyarország Kft.
+36 1919 0855
info(at)euchner.hu