TQ1-1211G024-5000 (Rend. sz. 103379)
Safety switch TQ, connection cable, connecting cable 5m
- Connecting cable, 5 m
- Auxiliary release from 3 sides
- Switching element 1211
- LED indicator
- Closed-circuit current principle

Ismertetés
Guard locking principle
Power to unlock: On a guard with guard locking based on the closed-circuit current principle, the guard is locked by spring force until the guard locking solenoid is supplied with power. Unlocking is by solenoid force. The term mechanical guard locking is also used.
Guard locking for process protection
The safety switch meets the requirements for interlocking devices with guard locking for process protection. It does not possess safe guard lock monitoring.
Switching element
1211 | Slow-action switching contact |
Contacts for guard locking: 1 NC contact 1 NO contact | |
Contacts for door monitoring: 2 positively driven contacts |
LED indicator
The LED indicator illuminates when voltage is applied to the guard locking solenoid.
Auxiliary release with triangular wedge
The auxiliary release makes it possible to access the machine if there is a malfunction, e. g. a power failure. Unlocking is performed using a tool or a key. The auxiliary release must be protected against misuse (sealing, lacquer).
Scope of delivery
Triangular key for manual release is included in the scope of delivery.
Accessories required
Actuator is not included.


Dimensional drawings

1 | Triangular key |
Connection examples

Műszaki adatok
Approvals



Electrical connection values
Fuse | max. 2 A gG |
Power consumption | 2.7 W |
Rated insulation voltage Ui | 300 V |
Rated impulse voltage Uimp | 2.5 kV |
Utilization category | |
DC-13 Monitoring contact | 0.22 A 125 V |
AC-15 Safety contact | 0.75 A 250 V |
DC-13 Safety contact | 0.27 A 250 V |
AC-15 Monitoring contact | 1 A 125 V |
Solenoid operating voltage | |
DC | 24 V -15% ... +10% |
Solenoid duty cycle | 100 % |
Switching voltage | |
min. at 10 mA | 12 V |
Switching current | |
min. at 24 V | 1 mA |
thermal rated current Ith | 2.5 A |
Mechanical values and environment
Approach speed | 3 ... 60 m/min |
Connection type | Connecting cable, 5 m |
Number of guard lock monitoring NC contacts | 1 |
Number of door position NO contacts | 1 |
Number of guard lock monitoring NO contacts | 1 |
Number of door position positively driven contacts | 2 |
Extraction force | 10 N |
Actuation frequency | max. 900 1/h |
Actuating force | 5 N |
Installation orientation | any |
Insertion depth | 26.3 mm |
Mechanical life | 1 x 10⁶ |
Retention force | 1 N |
Switching principle | Slow-action switching contact |
Degree of protection | IP67 |
Ambient temperature | -20 ... 50 °C |
Material | |
Contact | Silver alloy, gold flashed |
Housing | Reinforced thermoplastic |
Locking force Fmax | 500 N |
Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
B10D | Mission time | |
---|---|---|
Monitoring of the guard position | 2x106 | 20 y |
Important! Values valid for DC-12 100 mA/24V |
In combination with actuator ACTUATOR-Q-WTB
Horizontal overtravel | 1.3 mm |
In combination with actuator ACTUATOR-Q-GT, HINGED ACTUATOR-Q-RO, HINGED ACTUATOR-Q-LU, ACTUATOR-Q-WT
Horizontal overtravel | 1.9 mm |
Tartozékok

BETAETIGER-Q-GT
- With rubber bush
- Minimum door radius 160 mm
- Maximum locking force 500 N
- Mounting aid included

BETAETIGER-Q-WT
- With rubber bush
- Minimum door radius 160 mm
- Maximum locking force 500 N
- Mounting aid included

BETAETIGER-Q-WTB
- With rubber bush
- Minimum door radius 160 mm
- Maximum locking force 500 N
- With mounting plate
- Mounting aid included
Letöltések
Teljes csomag
Minden fontos dokumentum letöltése egyetlen kattintással.
Tartalom:
- A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
- A használati utasítást kiegészítő adatlapok
- A megfelelőségi nyilatkozat
Egyedi dokumentumok







Egyéb dokumentumok


Rendelési adatok
Rend. sz. | 103379 |
Cikk neve | TQ1-1211G024-5000 |
Súly | 0,586kg |
Vámtarifaszám | 85365019000 |
ECLASS | 27-27-26-03 Safety switch with guard control |