Non-contact safety switch CMS-R-BZB-01V-AS1, with connecting cable and plug connector M12
- Safety switches with integrated read head and integrated evaluation unit.
- Operating distance 7 mm

Ismertetés
Actuator
An appropriate actuator to suit the read head selected is required. The dimensions of the actuators are the same as those of the read heads, although the former have no connecting cable.
AS-Interface inputs
D0 - D3 | Switch actuated/open |
Evaluation is performed via a safety monitor.
Principle of operation
Reed contacts are installed in the read head of the safety system CMS. The contact blades on the reed contacts are closed under the influence of the magnetic field from the respective actuator. The read head only responds to the specific mating component, that is a specific actuator which is allocated to the read head type.


Dimension drawings

Connection examples

View of connection side |
Műszaki adatok
Approvals




Work area
Operating distance on | min. 7 mm |
Assured release distance sar | max. 40 mm |
Center offset | |
symmetrical, at distance s = 3 mm |
Electrical connection ratings
ASI data in | |
according to AS-i Safety at Work | D0, D1, D2, D3 (Switch actuated = code sequence / switch not actuated = zero sequence) |
ASI LED | |
LED red/yellow alternately flashing | No data exchange between master and slave (Slave address=0) |
LED green | Normal operation |
LED red | No data exchange between master and slave (Master in the STOP mode / Slave not in LPS / Slave with incorrect IO;ID / Reset active on the slave) |
LED red flashing | Fault |
LED red/green alternately flashing | Fault |
ASI slave type | |
according to ASI specification 3.0 | EA code: 0 |
according to ASI specification 3.0 | ID code: B |
ASI operating current | max. 30 mA |
ASI voltage | |
DC | 26.5 ... 30 ... 31.6 V |
Mechanical values and environment
Connection | hard-wired encapsulated cable with plug connector M12 |
Degree of protection | IP67 |
Design | B |
Material | |
Cable material | PUR |
Housing | Reinforced thermoplastic (PPS), fully encapsulated |
Mechanical life | 100 x 10⁶ |
Installation orientation | any (During mounting it must be ensured that the marking arrows on the actuator and the read head are opposite each other.) |
Reaction time | |
after change in the actuation status | max. 5 ms |
Cable length | 1 m |
Ambient temperature | -20 ... +60 °C |
Method of operation | magnetic, reed contact |
Reliability values acc. to EN ISO 13849-1
Mission time | 20 y |
Monitoring of the guard position | |
B10D | 3 x 10⁶ |
Category | 3 |
Performance Level | PL e |
PFHD | 4.29 x 10-8 |
Tartozékok
Letöltések
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents


Other Documents




Ordering data
Rend. sz. | 105094 |
Articlename | CMS-R-BZB-01P-AS1 |
Weight | 0,085kg |
Customsclass | 85389099 |