Non-contact safety switch CES-AP-CR2-..., flying lead, PVC
- Safety switch with integrated evaluation electronics
- No series connection
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Door hinge right
- Category 4 / PL e according to EN ISO 13849-1
- Connecting cable PVC, 5 m, flying lead, 6-core
- Multicode
- Two safety screws M4x14 included

Ismertetés
Short circuit monitoring
The switch generates its own clock signal on the output lines OA/OB.
Pay attention to this aspect when connecting to control systems and relays.
Multicode evaluation
Every suitable actuator is detected by the switch.
Category according to EN 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- Category 4/PL e according to EN 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.
LED indicator
STATE | Status LED |
DIA | Diagnostics LED |
Typical actuating range
(Actuator CES-A-BLN... in conjunction with safety switch CES-AP-C.2-... in case of mounting on plastic)

For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the actuating range of the side lobes is not entered.
Attention:
The actuating range may vary depending on the substrate material and installation situation.
Terminal assignment
Designation | Function | Connecting cable conductor coloring |
---|---|---|
UB | Power supply, DC 24 V | BN |
FO1A | Safety output, channel 1 | WH |
0V | Ground, DC 0 V | BU |
FO1B | Safety output, channel 2 | BK |
OUT | Monitoring output | GY |
- | n.c. | PK |


Dimension drawings

1 | Active face |
2 | Fastening lug with reinforcement plate |
3 | LED status indication |
4 | Active face |
Connection examples

Műszaki adatok
Approvals



Work area
Repeat accuracy R | |
according to EN 60947-5-2 | <= 10 |
Electrical connection ratings
Current consumption | max. 30 mA (without taking into account the load currents on the monitoring output and the safety outputs) |
Fusing | |
external (operating voltage) | 0.25 ... 8 A |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Operating voltage DC | |
UB | 24 V DC -15% ... +15% regulated, residual ripple < 5% |
Turn-on time | |
Safety outputs | max. 300 ms |
EMC protection requirements | according to EN IEC 60947-5-3 |
Utilization category | |
DC-13 | 24V 150mA (Caution: Outputs must be protected with a free-wheeling diode in case of inductive loads.) |
Risk time according to EN 60947-5-3 | max. 260 ms |
Safety class | III |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring output OUT | |
Output type | p-switching, short circuit-proof |
Output voltage | 0.8 x UB ... UB V DC |
Switching current | max. 50 mA |
Safety outputs OA / OB | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
rated conditional short-circuit current | 100 A |
Discrepancy time | max. 10 ms |
Output voltage | |
LOW U(OA,OB) | 0 ... 1 V DC |
HIGH U(OA,OB) | UB-1.5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.) |
Switching current | |
per safety output | 1 ... 150 mA |
Off-state current Ir | max. 0.25 mA |
Test pulses | max. 0.3 ms (Applies to a load with C <= 30 nF and R <= 20 kohm) |
Test pulse interval | min. 100 ms |
Mechanical values and environment
Connection | Connecting cable PVC, length 5 m |
Degree of protection | IP67/IP69K |
Ready delay | 0.5 s |
Material | |
Housing | Plastic, PBT |
Dynamic bending radius | 10 x cable diameter |
Static bending radius | 5 x cable diameter |
Installation orientation | any |
Switching frequency | max. 1 Hz |
Tightening torque | |
Fixing screws | max. 1 Nm |
Mounting distance | |
between 2 switches or 2 actuators | min. 400 mm |
Mounting type | Surface mounting on metal |
Shock and vibration resistance | according to EN IEC 60947-5-3 |
Cable ambient temperature (dynamic) | 0 ... +65 °C |
Cable ambient temperature (static) | -40 ... +65 °C |
Reliability values acc. to EN ISO 13849-1
Mission time | 20 y |
Monitoring of the guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 1.8 x 10-9 |
Miscellaneous
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures |
In combination with actuator CES-A-BDN-06-104730
Assured operating distances sao | min. 14 mm |
Assured release distance sar | |
in x/z direction | max. 40 mm |
in y direction | max. 60 mm |
Operating distance | 19 mm |
Switching hysteresis | 1 ... 2 mm |
In combination with actuator CES-A-BLN-R2-100776, CES-A-BLN-U2-103450, CES-A-BLN-L2-104510, CES-A-BLN-U2-112710
Assured operating distances sao | min. 10 mm |
Assured release distance sar | |
in x/z direction | max. 40 mm |
in y direction | max. 60 mm |
Operating distance | 15 mm |
Switching hysteresis | 1 ... 2 mm |
Tartozékok
Letöltések
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents








Other Documents

Homologation
Homologación
EAC
Homologação
Omologazione
认证
認可
승인
Сертификат
Atest
Engedély
Разрешително
Godkendelse
Heakskiit
Hyväksyntä
Έγκριση
Odobrenje
Atļauja
Patvirtinimas
Goedkeuring
Godkjenning
Dopuszczenie
Godkännande
Dovoljenje
Povolenie
Onay
Дозвіл

Homologation
Homologación
c UL us
Homologação
Omologazione
认证
認可
승인
Сертификат
Atest
Engedély
Разрешително
Godkendelse
Heakskiit
Hyväksyntä
Έγκριση
Odobrenje
Atļauja
Patvirtinimas
Goedkeuring
Godkjenning
Dopuszczenie
Godkännande
Dovoljenje
Povolenie
Onay
Дозвіл

Ordering data
Rend. sz. | 105600 |
Articlename | CES-AP-CR2-CH-L05-105600 |
Weight | 0,242kg |
Customsclass | 85365019 |