EUCHNER – More than safety.
EUCHNER – More than safety.
KezdőlapProductsCES-AH-C03-AE-LS-110370

CES-AH-C03-AE-LS-110370 (Rend. sz. 110370)

Non-contact safety switch CES-AH-C03-...

  • Safety switch with integrated evaluation electronics
  • Load currents of 4 A can be switched directly
  • 2 safety outputs (semiconductor outputs)
  • Category 3 / PL d according to EN ISO 13849-1
  • With connecting cable PUR, 0.5 m, with plug connector AMP Super Seal, 1x3-pin/1x4-pin
  • Approach direction C (not adjustable)
  • Unicode
CES-AH-C03-AE-LS-110370 (Rend. sz. 110370)

Ismertetés

Unicode evaluation

Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in.

Only the last actuator taught-in is detected.

Category according to EN ISO 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 3/PL d according to EN ISO 13849-1

Each safety path is independently safe.

LED indicator

STATE

Status LED

DIA

Diagnostics LED

Attention:

The actuating range may vary depending on the substrate material and installation situation.

Typical actuating range
(only in combination with actuator CES-A-BRN)

<p>Typical actuating range<br>(only in combination with actuator CES-A-BRN)</p>
Dimension drawing
Dimension drawing
Block diagram
Block diagram

Dimension drawings

Dimension drawings
1PUR
2PVC
3Active face
4Cable length 500 mm
5LED status indication
6View of connection side

Connection examples

Connection examples

Műszaki adatok

Work area

Repeat accuracy R
according to EN 60947-5-2

Controls and indicators

LED indicator 2 STATE (green) and DIA (red)

Electrical connection ratings

Current consumption
no load on outputs max. 150 mA
Fusing
external (operating voltage, +LA and +LB) 0.25 ... 10 A
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 1.5 kV
Operating voltage DC
UB 9 ... 32 V DC reverse polarity protected, regulated, residual ripple < 5%
Turn-on time
Safety outputs LA / LB max. 400 ms
EMC protection requirements as per DIN EN 13309
Risk time according to EN 60947-5-3 max. 250 ms
Safety class III
Degree of contamination (external, according to EN 60947-1) 3
Time delay
In the fault state 5 s (The switch remains in the fault state for this time before a reset is performed.)
Power supply outputs
Power supply output load
U(+LA)/U(+LB) 9 ... 32 V DC (Power supply same UB, same ground potential.)
Pulse frequency
Power supply for load via PWM max. 1 kHz
Duty cycle Ton
Power supply for load via PWM 0.1 ... 1
Safety output +LA/LA, +LB/LB
Output type Semiconductor output, p-switching, short circuit-proof
rated conditional short-circuit current max. 100 A
Discrepancy time max. 50 ms
Output voltage
HIGH U(LA/LB) U(+LA/+LB) - 1.5 ... U(+LA/+LB) V DC (Values at a switching current of 4A without taking into account the cable lengths.)
LOW U(LA/LB) 0 ... 4 V DC
Switching current 30 ... 4000 mA
Utilization category
DC-13 24V 4A (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
Off-state current Ir max. 0.5 mA
Test pulses max. 6 ms (With series connection, the value increases according to the number of switches used.)
Test pulse interval min. 10000 ms
Start input
Input voltage
HIGH 8 ... UB V DC
LOW 0 ... 2 V DC

Mechanical values and environment

Dimensions 40 x 40 x 168
Connection Connecting cable PUR, 0.5 m, with plug connector AMP Super Seal, 1x3-pin / 1x4-pin
Degree of protection IP65/IP67
Ready delay max. 3 s (After the operating voltage is switched on, the semiconductor outputs are switched off during the ready delay.)
Material
Housing Plastic, PBT
Static bending radius 10 x cable diameter
Installation orientation any
Switching frequency max. 1 Hz
Tightening torque
Fixing screws max. 1 Nm
Mounting distance
between 2 switches or actuators min. 80 mm
Shock and vibration resistance according to EN IEC 60947-5-3
Ambient temperature -25 ... +70 °C
Dwell time min. 0.5 s (The dwell time of an actuator inside and outside the actuating range must be at least 0.5 s to ensure safe detection of internal faults in the evaluation unit (self-monitoring).)

Reliability values acc. to EN ISO 13849-1

Mission time 20 y
Monitoring of the guard position
Category 3
Performance Level PL d
PFHD 1.03 x 10-7

In combination with actuator CES-A-BRN-100251

Actuator distance s
for side approach min. 6 mm (Minimum distance to prevent switching on in the side lobe of the read head.)
Assured operating distances sao min. 27 mm (The values apply to surface mounting of the actuator on steel.)
Assured release distance sar max. 75 mm
Operating distance 32 mm
Switching hysteresis 3 mm (The values apply to surface mounting of the actuator on steel.)

Letöltések

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download complete package (ZIP, 2,1 MB)

Ordering data

Rend. sz. 110370
Articlename CES-AH-C03-AE-LS-110370
Weight 0,7kg
Customsclass 85365019

Műszaki támogatás

Műszaki támogatás
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER Magyarország Kft.
+36 1919 0855
info(at)euchner.hu