EUCHNER – More than safety.
EUCHNER – More than safety.
 

CES-AH-C03-AE-LS-110370 (Rend. sz. 110370)

Non-contact safety switch CES-AH-C03-...

  • Safety switch with integrated evaluation electronics
  • Load currents of 4 A can be switched directly
  • 2 safety outputs (semiconductor outputs)
  • Category 3 / PL d according to EN ISO 13849-1
  • With connecting cable PUR, 0.5 m, with plug connector AMP Super Seal, 1x3-pin/1x4-pin
  • Approach direction C (not adjustable)
  • Unicode
CES-AH-C03-AE-LS-110370 (Rend. sz. 110370)

Ismertetés

Unicode evaluation

Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in.

Only the last actuator taught-in is detected.

Category according to EN ISO 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 3 / PL d according to EN ISO 13849-1

Each safety path is independently safe.

LED indicator

STATE

Status LED

DIA

Diagnostics LED

Attention:

The actuating range may vary depending on the substrate material and installation situation.

Typical actuating ranges
(Only in combination with actuator CES-A-BRN)

<p>Typical actuating ranges<br>(Only in combination with actuator CES-A-BRN)</p>
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings
1PUR
2PVC
3Active face
4Cable length 500 millimeters
5LED status indication
6View of connection side

Connection examples

Connection examples

Műszaki adatok

Workspace

Repeat accuracy R
according to EN 60947-5-2 <= 10

Operating and display elements

LED display 2 STATE (green) and DIA (red)

Electrical connection values

Fuse
external (operating voltage, +LA and +LB) 0.25 ... 10 A
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 1.5 kV
Operating voltage DC
UB 9 ... 32 V DC reverse polarity protected, regulated, residual ripple<5%
Turn-on time
Safety outputs LA / LB max. 400 ms
EMC protection requirements as per DIN EN 13309
Risk time according to EN 60947-5-3 max. 250 ms
Safety class III
Current consumption
no load on outputs max. 150 mA
Degree of contamination (external, according to EN 60947-1) 3
Time delay
In the fault state 5 s (The switch remains in the fault state for this time before a reset is performed.)
Power supply outputs
Power supply output load
U(+LA)/U(+LB) 9 ... 32 V DC (Power supply same UB, same ground potential.)
Pulse frequency
Power supply for load via PWM max. 1 kHz
Duty cycle Ton
Power supply for load via PWM 0.1 ... 1
Safety output +LA/LA, +LB/LB
Output type Semiconductor output, p-switching, short circuit-proof
Output voltage
LOW U(LA/LB) 0 ... 4 V DC
HIGH U(LA/LB) U(+LA/+LB) - 1.5 ... U(+LA/+LB) V DC (Values at a switching current of 4 A without taking into account the cable lengths.)
rated conditional short-circuit current max. 100 A
Discrepancy time max. 50 ms
Utilization category
DC-13 24 V 4 A (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
Off-state current Ir max. 0.5 mA
Switching current 30 ... 4000 mA
Test pulse duration max. 6 ms (With series connection, the value increases according to the number of switches used.)
Test pulse interval min. 10000 ms
Start input
Input voltage
LOW 0 ... 2 V DC
HIGH 8 ... UB V DC

Mechanical values and environment

Dimensions 40 x 40 x 168
Connection type Connecting cable PUR, 0.5 m, with plug connector AMP Super Seal, 1x3-pin / 1x4-pin
Tightening torque
Fixing screws max. 1 Nm
Ready delay max. 3 s (After the operating voltage is switched on, the semiconductor outputs are switched off during the ready delay.)
Static bending radius 10 x cable diameter
Installation orientation any
Switching frequency max. 1 Hz
Mounting distance
between 2 switches or actuators min. 80 mm
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65/IP67
Ambient temperature -25 ... +70 °C
Dwell time min. 0.5 s (The dwell time of an actuator inside and outside the actuating range must be at least 0.5 s to ensure safe detection of internal faults in the evaluation unit (self-monitoring).)
Material
Housing Plastic, PBT

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of the guard positionPL d-1.03x10-7320 y


In combination with actuator CES-A-BRN-100251

Actuator distance s
for side approach min. 6 mm (Minimum distance to prevent switching on in the side lobe of the read head.)
Switch-on distance 32 mm
Secured switch-off distance sar max. 75 mm
Secured switching distance sao min. 27 mm (The values apply to surface mounting of the actuator on steel.)
Switching hysteresis 3 mm (The values apply to surface mounting of the actuator on steel.)

Letöltések

Teljes csomag

Minden fontos dokumentum letöltése egyetlen kattintással.

Tartalom:

  • A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
  • A használati utasítást kiegészítő adatlapok
  • A megfelelőségi nyilatkozat
Teljes csomag letöltése (ZIP, 2,3 MB)

Egyedi dokumentumok

Egyéb dokumentumok

Rendelési adatok

Rend. sz. 110370
Cikk neve CES-AH-C03-AE-LS-110370
Súly 0,7kg
Vámtarifaszám 85365019000
ECLASS 27-27-24-03 Safety-related transponder switch

Műszaki támogatás

Műszaki támogatás
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER Magyarország Kft.
+36 1919 0855
info(at)euchner.hu