EUCHNER – More than safety.
EUCHNER – More than safety.

MGB-L0B-PNA-L-124128 (Rend. sz. 124128)

Interlocking module and bus module MGB-L0...-PN with 2 control elements, 7/8" and M12 plugs

  • Interlocking (without guard locking)
  • Emergency stop according to ISO 13850, illuminated
  • 2 illuminated pushbuttons
  • including adhesive labels
  • Connection via 7/8" and M12 plugs
  • Pre-assembled on mounting plates
  • Integrated Profinet RT switch
  • Unicode
MGB-L0B-PNA-L-124128 (Rend. sz. 124128)

Ismertetés

Profinet connection

7/8" plugs according to ANSI/B93.55M-1981 and M12 plugs (d-coded) according to IEC 61076-2-101

Profinet RT switch

Point-to-point topology network structure due to integrated RT switch.

Illuminated emergency stop

Emergency stop with illumination that can be controlled as required.

Dimension drawing
Dimension drawing

Dimensional drawings

Dimensional drawings

Műszaki adatok

Approvals

TUEV Süd München_M6A 040393 0042 Rev. 00c_UL_us_E155795_3/9EAC_RU C-DE.HX37.B.14157/20

Workspace

Secured switch-off distance sar
Door position max. 65 mm

Operating and display elements

Occupancy diagram
L0
B1
ItemExtrasColorDesignation1NumberLEDSlide-in labelSwitching elementVersionNote slide-in label
901NOIlluminated pushbutton
932 PDEmergency stop illuminated
951NOIlluminated pushbutton

Electrical connection values

Connecting cable
Ethernet Profinet I/O cable, at least cat. 5e
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0.5 kV
EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
maximum feed-in current in the connection block
X1, X2 max. 4000 mA
Safety class III
Current consumption max. 500 mA
Transponder coding Unicode
Degree of contamination (external, according to EN 60947-1) 3
Power supply X1
Fuse
external min. 1 A slow blow
Operating voltage DC
L1 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
Power supply X2
Operating voltage DC
L1 24 V DC -15% ... +10% (For looping through for connected devices)
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (For looping through for connected devices)

Mechanical values and environment

Connection type
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e M12, D-coded, screened (X3 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.))
7/8" Power (X1 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.))
7/8" Power (X2 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.))
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e M12, D-coded, screened (X4 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.))
Installation orientation Door hinge DIN left
Switching frequency 0.25 Hz
Mechanical life
1 x 10⁶
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
Response time
Emergency stop / machine stop max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Door position max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Bolt position max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP54
Ambient temperature
at UB = 24 V DC -20 ... +55 °C
Material
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y
Emergency stop
B10D
Emergency stop 0.13 x 10⁶
Emergency-stop evaluation
Category 4
Performance Level PL e
PFHD 4.1 x 10-8
Monitoring of the guard position
Diagnostic Coverage (DC) 99 %
Category 4
Performance Level PL e
PFHD 4.07 x 10-8 (Fixed failure rate without consideration of faults in wearing parts.)
Safety Integrity Level SIL 3 (EN 62061:2005)

Miscellaneous

Slide-in label
NumberLabelingNote
2without marking
Product version number V3.30.10
Additional feature incl. lens set, ID no. 120344

Interface

Bus data protocol Profinet (IEC 61158 type 10)
Safety data protocol Profisafe (IEC 61784-3-3)
Date interface
Ethernet

Letöltések

Teljes csomag

Minden fontos dokumentum letöltése egyetlen kattintással.

Tartalom:

  • A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
  • A használati utasítást kiegészítő adatlapok
  • A megfelelőségi nyilatkozat
Teljes csomag letöltése (ZIP, 6,6 MB)

Egyedi dokumentumok

Egyéb dokumentumok

Rendelési adatok

Rend. sz. 124128
Cikk neve MGB-L0B-PNA-L-124128
Súly 3,496kg
GTIN 4047048006430
Vámtarifaszám 85371098
ECLASS 27-27-24-03 Safety-related transponder switch

Műszaki támogatás

Műszaki támogatás
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER Magyarország Kft.
+36 1919 0855