Non-contact safety switches CES-I-BR-.-C07, M12
- Safety switch with integrated evaluation electronics
- Several devices can be connected in series, max. 20
- Multicode
- 2 safety outputs (semiconductor outputs)
- Short circuit monitoring
- Category 4 / PL e according to EN ISO 13849-1
- Monitoring output OD
- Diagnostic information via BR/IO-Link Gateway GWY-CB or ESM-CB
- Three active faces
- Plug connector M12, 8-pin (aligned)
- Switch chains up to 200 m long

Ismertetés
Industry 4.0 ready
The switch can communicate in combination with an EUCHNER BR IO-Link Gateway, and sends process and device data to higher-level control systems. Comprehensive diagnostic messages enable rapid and targeted troubleshooting.
Multicode evaluation
Every suitable actuator is detected by the switch.
Category according to EN 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- Category 4/PL e according to EN 13849-1
Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated.
LED indicator
STATE | Status LED |
DIA | Diagnostics LED |
Terminal assignment
Pin | Designation | Function |
---|---|---|
1 | FI1B | Enable input for channel B |
2 | UB | Power supply, DC 24 V |
3 | FO1A | Safety output, channel A |
4 | FO1B | Safety output, channel B |
5 | OD/C | Monitoring output/communication |
6 | FI1A | Enable input for channel A |
7 | 0V | Ground, DC 0 V |
8 | nc | n.c. |
Notice
The caps for the mounting holes are included.
Dimension drawings

1 | LEDs |
2 | Active face |
3 | With the installation orientation shown: cable outlet on left or right |
Connection examples

Műszaki adatok
Approvals







Work area
Repeat accuracy R | |
according to EN 60947-5-2 |
Electrical connection ratings
Current consumption | 40 mA |
Fusing | |
external (operating voltage) | 0.25 ... 8 A |
rated conditional short-circuit current | 100 A |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Operating voltage DC | |
UB | 24 V DC -15% ... +15% regulated, residual ripple < 5%, PELV |
Turn-on time | |
Safety outputs | max. 100 ms |
EMC protection requirements | according to EN IEC 60947-5-3 |
Risk time according to EN 60947-5-3 | |
Single device | max. 125 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 10 ms |
Safety class | III |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring output OD/C | |
Output type | p-switching, short circuit-proof |
Output voltage | UB-1.5 ... UB V DC |
Switching current | 1 ... 50 mA |
Safety outputs FO1A / FO1B | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Discrepancy time | max. 10 ms |
Output voltage | |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
HIGH U(FO1A) / U(FO1B) | UB-1.5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.) |
Switching current | 1 ... 150 mA |
Utilization category | |
DC-13 | 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
Off-state current Ir | max. 0.25 mA |
Test pulses | 0.3 ms (Applies to a load with C <= 30 nF and R <= 20 kohm) |
Test pulse interval | ca 100 ms |
Mechanical values and environment
Dimensions | 40 x 26.5 x 18 |
Connection | M12 plug connector, 8-pin |
Degree of protection | IP65/IP67/IP69/IP69K |
Ready delay | 5 s |
Material | |
Housing | Plastic, PBT-PC-GF30 |
Operating altitude | max. 4 000 m |
Installation orientation | any |
Switching frequency | max. 1 Hz |
Tightening torque | max. 0.8 Nm |
Mounting distance | |
between 2 switches or 2 actuators | min. 50 mm |
Mounting type | Surface mounting on metal |
Shock and vibration resistance | according to EN IEC 60947-5-3 |
Ambient temperature | |
at UB = 24 V DC | -25 ... +55 °C (+65 °C at IL = max. 10 mA per safety output) |
Reliability values acc. to EN ISO 13849-1
Mission time | |
according to EN ISO 13849-1 | 20 y |
SIL CL | |
nach EN 62061:2005/A2:2015 | 3 |
Monitoring of the guard position | |
Category | |
according to EN ISO 13849-1 | 4 |
Performance Level | |
according to EN ISO 13849-1 | PL e |
PFHD | |
according to EN ISO 13849-1 | 6 x 10E-10 |
Miscellaneous
Additional feature | Caps included |
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures |
In combination with actuator CES-A-BDN-06-158210, CES-A-BTN-C07-156230
Switching hysteresis | 1 ... 2 mm |
In combination with actuator CES-A-BTN-C07-156230
Assured operating distances sao | |
in x direction/installation position B | min. 9 mm |
in x direction/installation position A | min. 10 mm |
in x direction/installation position C | min. 3 mm |
in x direction/installation position D | min. 2 mm |
Assured release distance sar | |
in x direction/installation position C + D | max. 17 mm |
in x direction/installation position A + B | max. 20 mm |
Operating distance | |
Installation position A + B | 13 mm |
Installation position C + D | 7 mm |
In combination with actuator CES-A-BDN-06-158210
Assured operating distances sao | |
in x direction/installation position A | min. 13 mm |
in x direction/installation position C | min. 6 mm |
Assured release distance sar | |
in x direction/installation position A | max. 24 mm |
in x direction/installation position C | max. 21 mm |
Operating distance | |
Installation position C | 8 mm |
Installation position D | 7 mm |
Installation position B | 11 mm |
Installation position A | 16 mm |
Tartozékok

AC-YD-V0,2-SBB-158192
- For series connection of BR safety switches in switch chains with IO-Link evaluation
- Y-distributor with M12 female plug, 8-pin
- Male plug straight, 5-pin
- Female plug straight, 5-pin
- TPU housing, black
- Cable length 0.2 m / PVC

AC-YD-V1,0-SBB-158193
- For series connection of AR/BR safety switches in switch chains with ESM-CB for IO-Link evaluation
- Y-distributor with M12 female plug, 8-pin
- Male plug straight, 5-pin
- Female plug straight, 5-pin
- TPU housing, black
- Cable length 1.0 m

AC-YD-V0,2-SBB-111696
- For series connection of AR/BR safety switches in switch chains without IO-Link evaluation
- Y-distributor M12 with connecting cable, 2 x 5-pin, 1 x 8-pin
- Straight plug connector
- PVC cable
- Cable length 0.2 m

AC-YD-V1,0-SBB-112395
- For series connection of AR/BR safety switches in switch chains without IO-Link evaluation
- Y-distributor M12 with connecting cable, 2 x 5-pin, 1 x 8-pin
- Straight plug connector
- PVC cable
- Cable length 1 m
Letöltések
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents







Other Documents

Homologation
Homologación
EAC
Homologação
Omologazione
认证
認可
승인
Сертификат
Atest
Engedély
Разрешително
Godkendelse
Heakskiit
Hyväksyntä
Έγκριση
Odobrenje
Atļauja
Patvirtinimas
Goedkeuring
Godkjenning
Dopuszczenie
Godkännande
Dovoljenje
Povolenie
Onay
Дозвіл

Homologation
Homologación
c UL us
Homologação
Omologazione
认证
認可
승인
Сертификат
Atest
Engedély
Разрешително
Godkendelse
Heakskiit
Hyväksyntä
Έγκριση
Odobrenje
Atļauja
Patvirtinimas
Goedkeuring
Godkjenning
Dopuszczenie
Godkännande
Dovoljenje
Povolenie
Onay
Дозвіл










Ordering data
Rend. sz. | 156233 |
Articlename | CES-I-BR-M-C07-SA-156233 |
Weight | 0,055kg |
Customsclass | 85365019 |