EUCHNER – More than safety.
EUCHNER – More than safety.
 

CES-IA-BR-U-C07-SA-165893 (Rend. sz. 165893)

Complete set comprising non-contact safety switch CES-C07, with actuator

  • Safety switch with integrated evaluation electronics
  • Actuator included
  • Several devices can be connected in series, max. 20
  • Unicode
  • 2 safety outputs (semiconductor outputs)
  • Short circuit monitoring
  • Category 4 / PL e according to EN ISO 13849-1
  • Monitoring output OD
  • Diagnostic information via BR/IO-Link Gateway GWY-CB or ESM-CB
  • Three active faces
  • Plug connector M12, 8-pin (aligned)
  • Switch chains up to 200 m long
CES-IA-BR-U-C07-SA-165893 (Rend. sz. 165893)

Ismertetés

Installation position

Permissible installation position

Industry 4.0 ready

The switch can communicate in combination with an EUCHNER BR IO-Link Gateway, and sends process and device data to higher-level control systems. Comprehensive diagnostic messages enable rapid and targeted troubleshooting.

Unicode evaluation

Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.

Category according to EN 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4/PL e according to EN 13849-1

Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated.

LED indicator

STATE

Status LED

DIA

Diagnostics LED

Terminal assignment

PinDesignationFunction
1FI1BEnable input for channel B
2UBPower supply, DC 24 V
3FO1ASafety output, channel A
4FO1BSafety output, channel B
5OD/CMonitoring output/communication
6FI1AEnable input for channel A
70 VGround, DC 0 V
8ncn.c.

Notice

The caps for the mounting holes are included.

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
CES-C07: Transponder-coded safety switch

Dimensional drawings

Dimensional drawings
1LEDs
2Active face
3With the installation orientation shown: cable outlet on left or right

Connection examples

Connection examples

Műszaki adatok

Approvals

EAC_RU C-DE.MO05.B.00971/20TUEV Süd München_Z10 040393 0031 Rev. 02c_UL_us_E346349_1/1ECOLAB__

Switch CES-I-BR-U-C07-SA-157920 (Order no. 157920)

Switch CES-I-BR-U-C07-SA-157920  (Order no. 157920)

Workspace

Repeat accuracy R
according to EN 60947-5-2 <= 10

Electrical connection values

Fuse
external (operating voltage) 0.25 ... 8 A
rated conditional short-circuit current 100 A
Rated insulation voltage Ui 300 V
Rated impulse withstand voltage Uimp 1.5 kV
Operating voltage DC
UB 24 V DC -15% ... +15% regulated, residual ripple<5%, PELV
Turn-on time
Safety outputs max. 100 ms
EMC protection requirements Acc. to EN IEC 60947-5-3
Risk time according to EN 60947-5-3 max. 125 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 10 ms
Safety class III
Current consumption 40 mA
Degree of contamination (external, according to EN 60947-1) 3
Monitoring output OD/C
Output type p-switching, short circuit-proof
Output voltage UB-1.5 ... UB V DC
Switching current 1 ... 50 mA
Safety outputs FO1A / FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
HIGH U(FO1A) / U(FO1B) UB-1.5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.)
Discrepancy time max. 10 ms
Utilization category
DC-13 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
Off-state current Ir max. 0.25 mA
Switching current 1 ... 150 mA
Test pulse duration 0.3 ms (Applies to a load with C<= 30 nF and R<= 20 kohm)
Test pulse interval ca 100 ms

Mechanical values and environment

Dimensions 40 x 26.5 x 18
Connection type M12 plug connector, 8-pin
Tightening torque max. 0.8 Nm
Ready delay 5 s
Operating altitude max. 4 000 m
Installation orientation any
Switching frequency max. 1 Hz
Mounting distance
between 2 switches or 2 actuators min. 50 mm
Mounting type Surface mounting on metal
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65/IP67/IP69/IP69K
Ambient temperature
at UB = 24 V DC -25 ... +55 °C (+65 °C at IL= max. 10 mA per safety output)
Material
Housing Plastic, PBT-PC-GF30

Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures
Additional feature Caps included

Actuator CES-A-BTN-C07-156230 (Order no. 156230)

Actuator CES-A-BTN-C07-156230  (Order no. 156230)

Electrical connection values

Power supply Inductive via read head

Mechanical values and environment

Dimensions 40 x 26.5 x 18
Tightening torque
Fixing screws max. 0.8 Nm
Installation orientation active face opposite read head
Degree of protection IP65/IP67/IP69/IP69K
Ambient temperature -40 ... +65 °C
Material
Housing Plastic PBT-PC-GF30

Components included in the set

Included accessories 2x safety screws M4x20

Letöltések

Teljes csomag

Minden fontos dokumentum letöltése egyetlen kattintással.

Tartalom:

  • A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
  • A használati utasítást kiegészítő adatlapok
  • A megfelelőségi nyilatkozat
Teljes csomag letöltése (ZIP, 6,7 MB)

Egyedi dokumentumok

Egyéb dokumentumok

Rendelési adatok

Rend. sz. 165893
Cikk neve CES-IA-BR-U-C07-SA-165893
Súly 0,085kg
Vámtarifaszám 85365019

Műszaki támogatás

Műszaki támogatás
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER Magyarország Kft.
+36 1919 0855
info(at)euchner.hu