CES-IA-BP-U-C07-SI-167008 (Rend. sz. 167008)
Complete set comprising non-contact safety switch CES-C07, with actuator
- Safety switch with integrated evaluation electronics
- Actuator included
- Suitable for separate operation (no series connection)
- Unicode
- M12 plug connector, 5-pin (pin 5 not used)
- Direct connection to IP67 field modules
- 2 safety outputs (semiconductor outputs)
- Short circuit monitoring
- Category 4 / PL e according to EN ISO 13849-1
- Three active faces

Ismertetés
Unicode evaluation
Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.
Category according to EN 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- Category 4/PL e according to EN 13849-1
Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated.
LED indicator
STATE | Status LED |
DIA | Diagnostics LED |
Terminal assignment
| Pin | Designation | Function |
|---|---|---|
| 1 | UB | Power supply, DC 24 V |
| 2 | FO1A | Safety output, channel A |
| 3 | 0 V | Ground, DC 0 V |
| 4 | FO1B | Safety output, channel B |
| 5 | - | n.c. |
Notice
The caps for the mounting holes are included.
Dimensional drawings

| 1 | LEDs |
| 2 | Active face |
| 3 | With the installation orientation shown: cable outlet on left or right |
Connection examples

Műszaki adatok
Approvals




Mechanical values and environment
| Storage temperature | -25 ... 70 °C |
Switch CES-I-BP-U-C07-SI-162815 (Order no. 162815)
Workspace
| Repeat accuracy R | 10 % |
Electrical connection values
| Fuse | |
| external (operating voltage) | 0.25 ... 8 A |
| rated conditional short-circuit current | 100 A |
| Rated insulation voltage Ui | 75 V |
| Rated impulse voltage Uimp | 1.5 kV |
| Operating voltage DC | |
| UB | 24 V DC -15% ... +15% regulated, residual ripple<5%, PELV |
| Turn-on time | |
| Safety outputs | max. 100 ms |
| EMC protection requirements | Acc. to EN IEC 60947-5-3 |
| Risk time according to EN 60947-5-3 | max. 125 ms |
| Safety class | III |
| Current consumption | 40 mA |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| Monitoring output OD/C | |
| Output type | p-switching, short circuit-proof |
| Output voltage | UB-1.5 ... UB V DC |
| Switching current | 1 ... 50 mA |
| Safety outputs FO1A/FO1B | |
| Output type | Semiconductor outputs, p-switching, short circuit-proof |
| Output voltage | |
| HIGH U(FO1A) / U(FO1B) | UB-1.5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.) |
| LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
| Discrepancy time | max. 10 ms |
| Utilization category | |
| DC-13 | 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
| Off-state current Ir | max. 0.25 mA |
| Switching current | 1 ... 150 mA |
| Test pulse duration | 0.3 ms (Applies to a load with C<= 30nF and R<= 20kOhm) |
| Test pulse interval | ca 100 ms |
Mechanical values and environment
| Dimensions | 40 x 26.5 x 18 |
| Connection type | M12 plug connector, 5-pin |
| Tightening torque | max. 0.8 Nm |
| Ready delay | 5 s |
| Operating altitude | max. 4 000 m |
| Installation orientation | any |
| Switching frequency | max. 1 Hz |
| Storage temperature | -25 ... 70 °C |
| Mounting distance | |
| between switches | min. 50 mm |
| Mounting type | Surface mounting on metal |
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
| Degree of protection | IP65/IP67/IP69/IP69K |
| Ambient temperature | |
| at UB = 24 V DC | -25 ... 55 °C (+65 °C at IL = max. 10 mA per safety output) |
| Material | |
| Housing | Plastic, PBT-PC-GF30 |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| PL | Maximum SIL | PFHD | Category | Mission time | |
|---|---|---|---|---|---|
| Monitoring of the guard position | PL e | 3 | 6x10-10 | 4 | 20 y |
Miscellaneous
| Notices for UL approval | Operation only with UL Class 2 power supply or equivalent measures |
| Additional feature | Caps included |
Actuator CES-A-BTN-C07-156230 (Order no. 156230)
Electrical connection values
| Power supply | Inductive via read head |
Mechanical values and environment
| Dimensions | 40 x 26.5 x 18 |
| Tightening torque | |
| Fixing screws | max. 0.8 Nm |
| Storage temperature | -40 ... 70 °C |
| Degree of protection | IP65/IP67/IP69/IP69K |
| Ambient temperature | -40 ... 65 °C |
| Material | |
| Housing | Plastic PBT-PC-GF30 |
Components included in the set
| Included accessories | 2x safety screws M4x20 |
Komponensek

CES-I-BP-U-C07-SI-162815
Safety switch CES-I-BP-.-C07-..., RFID, plug connector(s) M12, for connection to decentralized peripheral systems
- Unicode
- M12 plug connector(s), 5-pin, pin 5 not assigned
- for connection to decentralized peripheral systems

CES-A-BTN-C07-156230
Actuator CES-A-BTN-C07
- Cube-shaped design, 40 x 26.5 x 18 mm
- 2x safety screws M4x20 included
Tartozékok
Letöltések
Teljes csomag
Minden fontos dokumentum letöltése egyetlen kattintással.
Tartalom:
- A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
- A használati utasítást kiegészítő adatlapok
- A megfelelőségi nyilatkozat
Egyedi dokumentumok
Egyéb dokumentumok
Rendelési adatok
| Rend. sz. | 167008 |
| Cikk neve | CES-IA-BP-U-C07-SI-167008 |
| Súly | 0,085kg |
| Vámtarifaszám | 85365019 |