CTM-LBI-BR-U-AZD-SA-167797 (Rend. sz. 167797)

Safety switch with guard locking CTM-LBI-BR BiState, RFID, plug connector(s) M12

  • BiState (bistable guard locking)
  • Guard locking for process protection
  • Control of guard locking via IO-Link communication
  • Unicode
  • Door position monitoring output/communication OD/C
  • Plug connector M12, 8-pin
  • Actuating/extraction/retention force: 35/30/15 N
  • Auxiliary release
CTM-LBI-BR-U-AZD-SA-167797 (Rend. sz. 167797)

Ismertetés

BiState (bistable guard locking)

The device has a function that prevents

  • people from accidentally becoming trapped in the event of a power failure or when the machine is switched off and the safety door is open


  • the activated guard locking is deactivated in the event of a power failure.

Guard locking for process protection

The safety switch meets the requirements for interlocking devices with guard locking for process protection. It does not possess safe guard lock monitoring.

Control of guard locking via IO-Link communication

Activating guard locking:

Guard locking actuated by spring force and controlled by bit CL (bit CL = 0).

Releasing guard locking:

Guard locking released by the device’s operating voltage and deactivated by bit CL (bit CL = 1)

Unicode evaluation

Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in.

Only the last actuator taught-in is detected.

Auxiliary release

The auxiliary release on the front allows access to the machine in the event of a malfunction, e.g. a power failure.

Terminal assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1FI1BEnable input, channel BWH
2UBOperating voltage electronics and magnet 24 V DC
BN
3FO1ASafety output, channel AGN
4FO1BSafety output, channel BYE
5OD/CDoor position monitoring output/communicationGY
6FI1AEnable input, channel APK
70VUBElectronics and solenoid operating voltage, 0 V DCBU
8-n.c.RD

Accessories required

Actuator is not included.

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings
1LEDs
2Active read head face
3Auxiliary release

Connection examples

Connection examples

Műszaki adatok

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/11FCC_2AJ58-07_

Workspace

Repeat accuracy R 10 %

Electrical connection values

Fuse
external (operating voltage UB) 0.7 ... 8 A
Power consumption
at max. switching frequency 3 W
Rated insulation voltage Ui 50 V
Rated impulse voltage Uimp 0.5 kV
Discrepancy time
both safety outputs max. 10 ms Acc. to EN IEC 60947-5-3
Turn-on time max. 400 ms
Solenoid duty cycle 100 %
Off-state current Ir max. 0.25 mA
Risk time according to EN 60947-5-3 max. 200 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 10 ms
Switching load DC 24V, UL Class 2 (alternatively, see operating instructions)
Safety class III
Test pulse duration max. 0.3 ms
Test pulse interval 100 ms
Degree of contamination (external, according to EN 60947-1) 3
Solenoid IMP
Input voltage
Guard locking not active (open) 20.4 ... 26.4 V DC
Guard locking active (closed) 0 ... 5 V DC
Current consumption
Guard locking not active (open) 20 ... 50 mA
Monitoring output OD/C
Output type p-switching, short circuit-proof
Output voltage 0.8xUB ... UB V DC
Switching current 1 ... 50 mA
Safety input 1
Current consumption max. 7 mA Safety inputs Fl1A/Fl1B
Safety outputs FO1A/FO1B
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Output voltage
HIGH U(FO1A) / U(FO1B) UB-1.5 ... UB V DC
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
Discrepancy time Acc. to EN IEC 60947-5-3
Utilization category
DC-13 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Electrical switching frequency max. 0.25 Hz
Switching current
per safety output FO1A / FO1B 1 ... 150 mA
Operating voltage UB
Operating voltage DC
UUB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
Current consumption
IUB at operating voltage UB = 24 V max. 500 mA

Mechanical values and environment

Anfahrgeschwindigkeit max. 20 m/min
Connection type Plug connector M12, 8-pin
Extraction force 30 N
Ready delay 5.5 s
Actuating force 35 N
Installation orientation any
Switching frequency max. 0.25 Hz
Storage temperature -25 ... 70 °C
Mechanical life 1 x 10⁶
Overtravel 2 mm
Retention force 15 N
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65/IP67 (In the inserted and screwed tight state)
Ambient temperature
at UB = 24 V DC -20 ... 60 °C
Material
Safety switch housing Reinforced thermoplastic
Seals Fluorinated rubber (FKM)
Locking force Fmax 1300 N
Locking force FZh 1000 N
Guard locking principle BiState

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of the guard positionPL e34.11x10-9420 y


Miscellaneous

Notices for UL approval Operation only with UL Class 2 power supply or equivalent measures; see operating instructions

Tartozékok

Letöltések

Teljes csomag

Minden fontos dokumentum letöltése egyetlen kattintással.

Tartalom:

  • A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
  • A használati utasítást kiegészítő adatlapok
  • A megfelelőségi nyilatkozat
Teljes csomag letöltése (ZIP, 4,4 MB)

Egyedi dokumentumok

Egyéb dokumentumok

Rendelési adatok

Rend. sz. 167797
Cikk neve CTM-LBI-BR-U-AZD-SA-167797
Súly 0,26kg
Vámtarifaszám 85365019
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking