CES-I-AP-U-C04-USI-EX-174983 (Rend. sz. 174983)

Safety switch CES-I-AR-.-C04-..., ATEX, RFID, plug connector(s) M12

  • ATEX version
  • Unicode
  • Connection cable, connecting cable PUR, 10 m, plug connector(s) M12, 5-pin, pin 5 not assigned
CES-I-AP-U-C04-USI-EX-174983 (Rend. sz. 174983)

Ismertetés

Version ATEX

Suitable for use in zones 2 and 22 (gases and dusts).
Application area II 3G D.

Housing guard

The Housing guard included in the scope of delivery protects the safety switch against impacts on the housing and the plug connector(s). The Housing guard must be fitted in order to achieve the specified explosion protection.

Approach direction and installation position

Permissible installation position

Unicode evaluation

Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in.

Only the last actuator taught-in is detected.

Safety characteristics

Thanks to two redundant safety outputs (semiconductor outputs) with internal monitoring, the device is suitable for:

  • Category 4 /PL e according to EN 13849-1
  • SIL 3 according to EN IEC 62061 Table 4

The OSSD outputs used check their function for short circuits and short circuits with test pulses.

LED indicator

STATE

Status LED

DIA

Diagnostics LED

Terminal assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1UBElectronics operating voltage, 24 V DCBN
2FO1ASafety output, channel AWH
30 VWeight 0 V DCBU
4FO1BSafety output, channel BBK
5-n.c.GY

Scope of delivery

  • Housing guard

  • Rubber pad

Accessories required

Actuator is not included.

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples

Műszaki adatok

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E346349_1/1

Workspace

Repeat accuracy R
according to EN 60947-5-2 <= 10

Electrical connection values

Fuse
external (operating voltage) 0.25 ... 8 A
Rated insulation voltage Ui 30 V
Rated impulse voltage Uimp 0.5 kV
Operating voltage DC
UB 24 V DC -15% ... +15% regulated, residual ripple<5%, PELV (The device tolerates voltage interruptions in the operating voltage, e.g. test pulses, of up to 5 ms. These voltage interruptions are also output on the outputs.)
Turn-on time
Safety outputs max. 300 ms
EMC protection requirements Acc. to EN IEC 60947-5-3
Risk time according to EN 60947-5-3 max. 260 ms
Safety class III
Current consumption
no load on outputs max. 35 mA
Degree of contamination (external, according to EN 60947-1) 3
Safety outputs FO1A/FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
HIGH U(FO1A) / U(FO1B) UB-1.5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.)
rated conditional short-circuit current 100 A
Discrepancy time max. 10 ms
Utilization category
DC-13 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
Off-state current Ir max. 0.25 mA
Switching current
per safety output 1 ... 150 mA
Test pulse duration max. 0.3 ms (Applies to a load with C<= 30nF and R<= 20kOhm)
Test pulse interval min. 100 ms

Mechanical values and environment

Connection type PUR cable, 100 mm, with plug connector M12x1, 5-pin; pin 5 not used
Tightening torque
Fixing screws max. 0.6 Nm
Ready delay 0.5 s
Dynamic bending radius 10 x cable diameter
Static bending radius 5 x cable diameter
Installation orientation any
Switching frequency max. 1 Hz
Storage temperature -25 ... 70 °C
Mounting distance
between switches min. 80 mm
Mounting type Surface mounting on metal
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP67
Cable ambient temperature (dynamic) -25 ... 65 °C
Cable ambient temperature (static) -25 ... 65 °C
Material
Housing guard Fiber glass reinforced plastic
Rubber support NBR 80 ±5 Shore
Housing Plastic, PBT

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of the guard positionPL e-4.1x10-9420 y


Miscellaneous

Explosion protection in accordance with ATEX Directive 2024/34/EU II 3 G Ex ic ec IIB T5 Gc X / II 3 D Ex ic tc IIIC T90°C Dc X
Notices for UL approval Operation only with UL Class 2 power supply or equivalent measures
Additional feature Rubber support included

In combination with actuator CES-A-BBN-C04-EX-137527

Switch-on distance
Installation position A or B (front side) 15 mm
Installation position C or D (broad side) 11 mm
Secured switch-off distance sar
in x/z direction max. 40 mm
in y direction max. 60 mm
Secured switching distance sao
Installation position A or B (front side) min. 10 mm
Installation position C or D (broad side) min. 6 mm
Switching hysteresis 1 ... 2 mm

Tartozékok

Letöltések

Teljes csomag

Minden fontos dokumentum letöltése egyetlen kattintással.

Tartalom:

  • A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
  • A használati utasítást kiegészítő adatlapok
  • A megfelelőségi nyilatkozat
Teljes csomag letöltése (ZIP, 2,2 MB)

Egyedi dokumentumok

Egyéb dokumentumok

Rendelési adatok

Rend. sz. 174983
Cikk neve CES-I-AP-U-C04-USI-EX-174983
Súly 0,111kg
Vámtarifaszám 85365019000
ECLASS 27-27-24-03 Safety-related transponder switch