EUCHNER – More than safety.
EUCHNER – More than safety.

CTS-C1-BP-CC-FLX-AP-VSA-167917 (Rend. sz. 167917)

Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12

  • Up to category 4 / PL e according to EN ISO 13849-1
  • Closed-circuit current principle
  • Connecting cable , PVC, 25 cm, plug connector M12, 8-pin
  • Monitoring outputs guard locking and door position 1
CTS-C1-BP-CC-FLX-AP-VSA-167917 (Rend. sz. 167917)

Ismertetés

Guard locking type

CTS-C1

Guard locking actuated by spring force and power-ON released (closed-circuit current principle).

FlexFunction

The actuator configures the switch on setup. Depending on the actuator selected, guard lock monitoring of the safety switch is active or inactive and evaluation of the actuator code takes place with a high or low coding level.

Auxiliary release / escape release

  • Auxiliary release on front and rear side

  • Escape release can be retrofitted, on rear side

Connector assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1IMPOperating voltage of solenoid 24 V DCWH
2UBElectronics operating voltage 24 V DCBN
3FO1ASafety output, channel AGN
4FO1BSafety output, channel BYE
5OX1/CMonitoring output 1 / communicationGY
6OX2Door monitoring output 2PK
70VUBElectronics operating voltage 0 V DCBU
8IMMOperating voltage of solenoid 0 V DCRD

Assignment of pins 5 and 6 depends on the function actuator

PinA-FLX-D-0C-167919A-FLX-D-0D-169044A-FLX-D-0E-169045A-FLX-D-0F-169046
L + HCI + HCL + LCI + LC
3

4

5OL/Cguard locking/communicationOL/Cguard locking/communicationOL/Cguard locking/communicationOL/Cguard locking/communication
6ODDoor position 1ODDoor position 1ODDoor position 1ODDoor position 1
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings
1Auxiliary release
2LEDs

Connection examples

Connection examples

Műszaki adatok

Approvals

FCC_CTS_2AJ58-18c_UL_us_E93776_5/1

Electrical connection values

Fuse
IMP 1 ... 8 A external
UB 1 ... 8 A external
Power consumption 9 W
rated conditional short-circuit current 100 A
Rated insulation voltage Ui 32 V
Rated impulse withstand voltage Uimp 0.8 kV
Operating voltage DC
UB 24 V DC -15% ... +20% (reverse polarity protected, regulated, residual ripple<5%, SELV)
Discrepancy time max. 10 ms
Turn-on time max. 400 ms
EMC protection requirements Acc. to EN 60947-5-3
Solenoid operating voltage DC 24 V DC -15% ... +20% reverse polarity protected, regulated, residual ripple<5%, SELV
Solenoid duty cycle 100 %
Risk time according to EN 60947-5-3 max. 200 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 10 ms
Switching load
according to UL DC 24 V, class 2
Safety class
EN IEC 61140 III
Current consumption
IIMP 500 mA
IUB 50 mA
Degree of contamination (external, according to EN 60947-1) 3
Monitoring outputs Ox/C
Output type p-switching, short circuit-proof
Output voltage 0.8xUB ... UB V DC
Output current
L configuration (guard lock monitoring active) 1 ... 20 mA
I-configuration (guard lock monitoring inactive) 1 ... 10 mA
Safety outputs FO1A/FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage
UFO1A /UFO1B LOW 0 ... 1 V DC
UFO1A /UFO1B HIGH UB-4V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
Output current
L configuration (guard lock monitoring active) 1 ... 80 mA
I-configuration (guard lock monitoring inactive) 1 ... 75 mA
Utilization category
DC-13 I configuration (guard lock monitoring inactive) 24 V 75 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
DC-13 L configuration (guard lock monitoring active) 24 V 80 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Test pulse duration max. 0.3 ms
Test pulse interval min. 96 ms

Mechanical values and environment

Approach speed max. 20 m/min
Extraction force 25 N
Ready delay max. 1 s
Actuating force 25 N
Installation orientation any
Mechanical life 1 x 10⁶
Retention force 10 N
Shock and vibration resistance Acc. to EN 60947-5-3
Degree of protection IP65/IP67/IP69/IP69K
Ambient temperature -20 ... +55 °C (A maximum value of +50 °C applies in the I-configuration of the switch (guard lock monitoring inactive))
Material
Safety switch housing Reinforced thermoplastic
Switch head cover Die-cast zinc
Connecting cable PVC
Locking force Fmax 3900 N
Locking force FZh 3000 N
Guard locking principle Closed-circuit current principle
Connection X1
Connection type Connecting cable with plug connector M12
Static bending radius 8x cable diameter
Cable outlet straight
Cable length 0.25 m
Number of pins 8
Safety outputs FO1A/FO1B
Switching frequency max. 0.2 Hz

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of the guard positionPL e36.44x10-9420 y
Monitoring of guard lockingPL e36.44x10-9420 y
Only applies with active guard lock monitoring (guard locking for personal protection). Depending on the actuator used.


PLMaximum SILCategoryMission time
Control of guard lockingDepending on external control of guard locking20 y


Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures; see operating instructions

Tartozékok

Letöltések

Teljes csomag

Minden fontos dokumentum letöltése egyetlen kattintással.

Tartalom:

  • A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
  • A használati utasítást kiegészítő adatlapok
  • A megfelelőségi nyilatkozat
Teljes csomag letöltése (ZIP, 12,4 MB)

Egyedi dokumentumok

Egyéb dokumentumok

Rendelési adatok

Rend. sz. 167917
Cikk neve CTS-C1-BP-CC-FLX-AP-VSA-167917
Súly 0,6kg
Vámtarifaszám 85365019000
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Műszaki támogatás

Műszaki támogatás
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER Magyarország Kft.
+36 1919 0855
info(at)euchner.hu