CMS-E-BR (Rend. sz. 085537)
Válasszon tartalmat
Evaluation unit CMS-E-BR, 1 safety contact, 1 auxiliary contact, 1 feedback loop can be connected
- 4 read heads can be connected
- 1 safety contact
- 1 auxiliary contact
- 1 feedback loop can be connected

Ismertetés
Functional description
The evaluation unit CMS-E-BR is suitable for the direct connection of up to 4 read heads.
Category/PL according to EN ISO 13849-1
- Category 4/PL e with only one read head connected
- Max. category 3/PL d with more than one read head connected
Notice:
At low approach speeds in the z direction, the time offset when switching the reed contacts must not be more than 150 ms.
Dimensional drawings

Connection examples

Műszaki adatok
Approvals



Operating and display elements
| LED display | 1 indicator LED Power (UB), green, 1 LED safety output (OUT, green/red) 8 LED status indicators (Dx1/Dx2/green/red) |
Electrical connection values
| Fuse | |||||||||||||
| Protection internal (operating voltage UB) | 0.5 A Automatically resetting fuse PTC | ||||||||||||
| Safety contacts 13/14 | 3 A gG (External contact fuse (safety circuit) acc. to EN IEC 60269-1) | ||||||||||||
| Connection cross section | 0.14 ... 2.5 mm² | Outputs | |||||||||||
| |||||||||||||
| Rated insulation voltage Ui | 250 V | ||||||||||||
| Operating voltage | |||||||||||||
| AC/DC | 24 V -10% ... +10% (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent insulation measures.) | ||||||||||||
| Utilization category | |||||||||||||
| DC-13 | 3A, 24V (Max. switching current per contact) | ||||||||||||
| AC-1 | 3A, 250V; 3A , 24V (Max. switching current per contact) | ||||||||||||
| AC-15 | 1A, 250V; 1A 24V (Max. switching current per contact) | ||||||||||||
| Risk time according to EN 60947-5-3 | max. 20 ms | ||||||||||||
| Switching load | |||||||||||||
| According to UL class 2 | Input: 24 V AC/DC; output: 30 V AC, 24 V DC | ||||||||||||
| Switching capacity (VA) | |||||||||||||
| Safety contact 13/14 | max. 750 VA | ||||||||||||
| Switching voltage | |||||||||||||
| Safety contact 13/14 | max. AC 250 V | ||||||||||||
| Switching current | |||||||||||||
| Safety contact 13/14 | 13 ... 3000 mA at 24V | ||||||||||||
| Current consumption | 250 mA | ||||||||||||
| Degree of contamination (external, according to EN 60947-1) | 2 | ||||||||||||
Mechanical values and environment
| Approach direction | Z (If the approach speed is low, the approach direction Z should be avoided.) |
| Connection type | Connection terminals, plug-in |
| Number of read heads | up to 4 read heads |
| Storage temperature | -25 ... 70 °C |
| Mechanical life | 30 x 10⁶ |
| Mounting type | Mounting rail TH 35 (EN IEC 60715) |
| Degree of protection | Terminals IP20 / housing IP40 |
| Ambient temperature | 0 ... 50 °C |
| Material | |
| Housing | Polycarbonate (PC) |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| PL | Maximum SIL | PFHD | Category | Mission time | ||
|---|---|---|---|---|---|---|
| Monitoring of the guard position | with 1 read head | PL e | - | 2.5x10-8 | 4 | 20 y |
| Only applies for switching voltage 24V DC and switching current up to 0.1 A (max. switching cycles 100,000 1/y) OR up to 1 A (max. switching cycles 18,500 1/y) OR up to 3 A (max. switching cycles 9,000 1/y) | ||||||
| with >1 read head | PL d | - | 1x10-7 | 3 | 20 y | |
| Only applies for switching voltage 24V DC and switching current up to 0.1 A (max. switching cycles 100,000 1/y) OR up to 1 A (max. switching cycles 18,500 1/y) OR up to 3 A (max. switching cycles 9,000 1/y) | ||||||
Miscellaneous
| in compliance with | EN ISO 13849-1: 2015; EN 50178: 1997; EN ISO 14119: 2013; EN 6100-6-3: 2007; EN 60947-5-2: 2007/A1: 2012; EN 60947-5-3: 2013 |
In combination with read head CMS-R-EXM-03V, CMS-R-EXM-05V, CMS-R-EXM-SC and actuator CMS-M-EF
| Secured switch-off distance sar | max. 17 mm (The assured release distance s_ar corresponds to the reset distance.) |
| Secured switching distance sao | |
| with center offset m=0 | min. 6 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
| Center offset | |
| at s = 3 mm read distance | 2,5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
In combination with read head CMS-R-AXH-03V, CMS-R-AXH-SC, CMS-R-AXH-05P and actuator CMS-M-AC
| Secured switch-off distance sar | max. 31 mm (The assured release distance s_ar corresponds to the reset distance.) |
| Secured switching distance sao | |
| with center offset m=0 | min. 6 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
| Center offset | |
| at s = 3 mm read distance | 2,5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
In combination with read head CMS-R-CXC-03V, CMS-R-CXC-05V, CMS-R-CXC-05P, CMS-R-CXC-SC and actuator CMS-M-CA
| Secured switch-off distance sar | max. 14 mm (The assured release distance s_ar corresponds to the reset distance.) |
| Secured switching distance sao | |
| with center offset m=0 | min. 6 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
| Center offset | |
| at s = 3 mm read distance | 2,5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
In combination with read head CMS-R-BXI-03V, CMS-R-BXI-05V, CMS-R-BXI-SC, CMS-R-BXI-07P and actuator CMS-M-BD
| Secured switch-off distance sar | max. 12 mm (The assured release distance s_ar corresponds to the reset distance.) |
| Secured switching distance sao | |
| with center offset m=0 | min. 3 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
| Center offset | |
| at s = 3 mm read distance | 2,5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
Tartozékok
CMS read heads
Letöltések
Teljes csomag
Minden fontos dokumentum letöltése egyetlen kattintással.
Tartalom:
- A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
- A használati utasítást kiegészítő adatlapok
- A megfelelőségi nyilatkozat
Teljes csomag letöltése (ZIP, 1,9 MB)
Egyedi dokumentumok
Declarations of conformity
EU-Konformitätserklärung
Dok. sz.
Változat
Nyelv
Méret
EU-Konformitätserklärung
Dok. sz.
EDC2112987
Változat
Nyelv
Méret
0,2 MB
UKCA-Konformitätserklärung
Dok. sz.
Változat
Nyelv
Méret
UKCA-Konformitätserklärung
Dok. sz.
EDC20001569
Változat
Nyelv
Méret
0,1 MB
Instructions
Operating Instructions Evaluation Unit CMS-E-BR
Dok. sz.
Változat
Nyelv
Méret
Operating Instructions Evaluation Unit CMS-E-BR
Mode d’emploi Analyseur CMS-E-BR
Manual de instrucciones Unidad de evaluación CMS-E-BR
Betriebsanleitung Auswertegerät CMS-E-BR
Mode d’emploi Analyseur CMS-E-BR
Manual de instrucciones Unidad de evaluación CMS-E-BR
Betriebsanleitung Auswertegerät CMS-E-BR
Dok. sz.
2099180
Változat
17-11/23
Nyelv
Méret
1,5 MB
Betriebsanleitung Auswertegerät CMS-E-BR
Dok. sz.
2099180
Változat
17-11/23
Nyelv
Méret
0,4 MB
Egyéb dokumentumok
Approvals and certificates
TUEV Süd München Z10 Zertifikat
Dok. sz.
Változat
Nyelv
Méret
TUEV Süd München Z10 Zertifikat
Dok. sz.
Változat
Nyelv
Méret
0,5 MB
WEEE
Dok. sz.
Változat
Nyelv
Méret
WEEE
Dok. sz.
ECO20001806
Változat
Nyelv
Méret
0,1 MB
c UL us
Dok. sz.
Változat
Nyelv
Méret
c UL us
Dok. sz.
Változat
Nyelv
Méret
1,0 MB
Sales documents
Interrupteurs de sécurité à codage magnétique CMS
Dok. sz.
Változat
Nyelv
Méret
Interrupteurs de sécurité à codage magnétique CMS
Dok. sz.
090606
Változat
10-11/20
Nyelv
Méret
5,8 MB
Rendelési adatok
| Rend. sz. | 085537 |
| Cikk neve | CMS-E-BR |
| Súly | 0,331kg |
| Vámtarifaszám | 85364110 |
| ECLASS | 27-27-24-02 Safety-related magnetic proximity switch |