Safety switch CTM-AS
Benefits for you
- Integrated AS-i connection
- Robust housing with degree of protection IP67/IP69/IP69K
- Compact design
- Comprehensive, detailed diagnostics option.
Design and functionality
The CTM-AS can be operated directly on the AS-i bus and provides the control system with both the door position and information about the locking position.Information about a possible malfunction in the switch can also be diagnosed directly in the control system.
Operation on all known AS-i safety monitors in the proven manner is a matter of course.
Termékek (5)
Nem található eredmény

171319
CTM-I2-AS2B-U-AZ-SJ-171319
Safety switch with guard locking CTM-AS ASi, RFID, plug connector(s) M12
CTM-I2-AS2B-U-AZ-SJ-171319
Safety switch with guard locking CTM-AS ASi, RFID, plug connector(s) M12
- AS-Interface
- Open-circuit current principle
- Guard locking for process protection
- Unicode
- Plug connector M12, 4-pin
- Actuating/extraction/retention force: 35/30/15 N
- Auxiliary release

163976
CTM-L2-AS1B-U-AZ-SJ-163976
Safety switch with guard locking CTM-AS ASi, RFID, plug connector(s) M12
CTM-L2-AS1B-U-AZ-SJ-163976
Safety switch with guard locking CTM-AS ASi, RFID, plug connector(s) M12
- AS-Interface
- Open-circuit current principle
- Guard locking for process protection
- Unicode
- Plug connector M12, 4-pin
- Actuating/extraction/retention force: 20/18/5 N
- Auxiliary release

163977
CTM-L2-AS1B-U-AZ-SJ-163977
Safety switch with guard locking CTM-AS ASi, RFID, plug connector(s) M12
CTM-L2-AS1B-U-AZ-SJ-163977
Safety switch with guard locking CTM-AS ASi, RFID, plug connector(s) M12
- AS-Interface
- Open-circuit current principle
- Guard locking for process protection
- Unicode
- Plug connector M12, 4-pin
- Actuating/extraction/retention force: 35/30/15 N
- Auxiliary release

163972
CTM-L2-AS1B-U-ZZ-SJ-P-163972
Safety switch with guard locking CTM-AS ASi, RFID, plug connector(s) M12, hygienic version
CTM-L2-AS1B-U-ZZ-SJ-P-163972
Safety switch with guard locking CTM-AS ASi, RFID, plug connector(s) M12, hygienic version
- AS-Interface
- Open-circuit current principle
- Guard locking for process protection
- Unicode
- Plug connector M12, 4-pin
- Actuating/extraction/retention force: 20/18/5 N
- Hygienic version

163974
CTM-L2-AS1B-U-ZZ-SJ-P-163974
Safety switch with guard locking CTM-AS ASi, RFID, plug connector(s) M12
CTM-L2-AS1B-U-ZZ-SJ-P-163974
Safety switch with guard locking CTM-AS ASi, RFID, plug connector(s) M12
- AS-Interface
- Open-circuit current principle
- Guard locking suitable for process protection only
- Unicode
- Plug connector M12, 4-pin
- Actuating/extraction/retention force: 35/30/15 N
- Hygienic version
