CES-AH-C03-AE-LS-110370 (Sip. No. 110370)
Choose content
Non-contact safety switch CES-AH-C03-...
- Safety switch with integrated evaluation electronics
- Load currents of 4 A can be switched directly
- 2 safety outputs (semiconductor outputs)
- Category 3 / PL d according to EN ISO 13849-1
- With connecting cable PUR, 0.5 m, with plug connector AMP Super Seal, 1x3-pin/1x4-pin
- Approach direction C (not adjustable)
- Unicode

Açıklama
Unicode evaluation
Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in.
Only the last actuator taught-in is detected.
Category according to EN ISO 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- Category 3 / PL d according to EN ISO 13849-1
Each safety path is independently safe.
LED indicator
STATE | Status LED |
DIA | Diagnostics LED |


Dimensional drawings

1 | PUR |
2 | PVC |
3 | Active face |
4 | Cable length 500 millimeters |
5 | LED status indication |
6 | View of connection side |
Connection examples

Teknik Veriler
Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | 10 % |
Operating and display elements
LED display | 2 STATE (green) and DIA (red) |
Electrical connection values
Fuse | |
external (operating voltage, +LA and +LB) | 0.25 ... 10 A |
Rated insulation voltage Ui | 75 V |
Rated impulse voltage Uimp | 1.5 kV |
Operating voltage DC | |
UB | 9 ... 32 V DC reverse polarity protected, regulated, residual ripple<5% |
Turn-on time | |
Safety outputs LA / LB | max. 400 ms |
EMC protection requirements | as per DIN EN 13309 |
Risk time according to EN 60947-5-3 | max. 250 ms |
Safety class | III |
Current consumption | |
no load on outputs | max. 150 mA |
Degree of contamination (external, according to EN 60947-1) | 3 |
Time delay | |
In the fault state | 5 s (The switch remains in the fault state for this time before a reset is performed.) |
Power supply outputs | |
Power supply output load | |
U(+LA)/U(+LB) | 9 ... 32 V DC (Power supply same UB, same ground potential.) |
Pulse frequency | |
Power supply for load via PWM | max. 1 kHz |
Duty cycle Ton | |
Power supply for load via PWM | 0.1 ... 1 |
Safety output +LA/LA, +LB/LB | |
Output type | Semiconductor output, p-switching, short circuit-proof |
Output voltage | |
HIGH U(LA/LB) | U(+LA/+LB) - 1.5 ... U(+LA/+LB) V DC (Values at a switching current of 4 A without taking into account the cable lengths.) |
LOW U(LA/LB) | 0 ... 4 V DC |
rated conditional short-circuit current | 100 A |
Discrepancy time | max. 50 ms |
Utilization category | |
DC-13 | 24V 4A (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
Off-state current Ir | max. 0.5 mA |
Switching current | 30 ... 4000 mA |
Test pulse duration | max. 6 ms (With series connection, the value increases according to the number of switches used.) |
Test pulse interval | min. 10000 ms |
Start input | |
Input voltage | |
HIGH | 8 ... UB V DC |
LOW | 0 ... 2 V DC |
Mechanical values and environment
Dimensions | 40 x 40 x 168 |
Connection type | Connecting cable PUR, 0.5 m, with plug connector AMP Super Seal, 1x3-pin / 1x4-pin |
Tightening torque | |
Fixing screws | max. 1 Nm |
Ready delay | max. 3 s (After the operating voltage is switched on, the semiconductor outputs are switched off during the ready delay.) |
Static bending radius | 10 x cable diameter |
Installation orientation | any |
Switching frequency | max. 1 Hz |
Storage temperature | -25 ... 70 °C |
Mounting distance | |
between switches | min. 80 mm |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP65/IP67 |
Ambient temperature | -25 ... 70 °C |
Dwell time | min. 0.5 s (The dwell time of an actuator inside and outside the actuating range must be at least 0.5 s to ensure safe detection of internal faults in the evaluation unit (self-monitoring).) |
Material | |
Housing | Plastic, PBT |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Monitoring of the guard position | PL d | - | 1.03x10-7 | 3 | 20 y |
In combination with actuator CES-A-BRN-100251
Actuator distance s | |
Minimum distance for side approach direction | min. 6 mm (Minimum distance to prevent switching on in the side lobe of the read head.) |
Switch-on distance | 32 mm |
Secured switch-off distance sar | max. 75 mm |
Secured switching distance sao | min. 27 mm (The values apply to surface mounting of the actuator on steel.) |
Switching hysteresis | 3 mm (The values apply to surface mounting of the actuator on steel.) |
Aksesuar
İndirme
Komple paket
Tüm önemli belgeleri tek bir tıklama ile indirin.
İçerik:
- Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
- Kullanım talimatlarını tamamlayan tüm veri sayfaları
- Uygunluk beyanı
Paketin tamamını indirin (ZIP, 2,1 MB)
Tek Belgeler
Declarations of conformity
EU-Konformitätserklärung
Dok. No.
Versiyon
Dil
Boyut

EU-Konformitätserklärung
Dok. No.
EDC2127387
Versiyon
Dil
Boyut
0,2 MB
UKCA-Konformitätserklärung
Dok. No.
Versiyon
Dil
Boyut

UKCA-Konformitätserklärung
Dok. No.
EDC20001500
Versiyon
Dil
Boyut
0,1 MB
Diğer Belgeler
Approvals and certificates
WEEE
Dok. No.
Versiyon
Dil
Boyut

WEEE
Dok. No.
ECO20001806
Versiyon
Dil
Boyut
0,1 MB
Sales documents
Sipariş verileri
Sip. No. | 110370 |
Makale adı | CES-AH-C03-AE-LS-110370 |
Ağırlık | 0,7kg |
Gümrük sınıfı | 85365019000 |
ECLASS | 27-27-24-03 Safety-related transponder switch |