EUCHNER – More than safety.
EUCHNER – More than safety.

CES-FD-AP-U-01-USI-119865 (Order no. 119865)

Field evaluation unit CES-FD-AP-…

  • Evaluation of signals in the field
  • Connection of CES read heads
  • Connection to the ET200s and ET200pro
  • Familiar EUCHNER AP interface
  • Unicode
CES-FD-AP-U-01-USI-119865 (Order no. 119865)

Description

Short circuit monitoring

The switch generates its own clock signal on the output lines FO1A/FO1B. Pay attention to this aspect when connecting to control systems and relays.

Category according to EN ISO 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4/PL e according to EN ISO 13849-1

Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (FO1A and FO1B) must always be evaluated.

LED indicator

STATE

Status LED

DIA

Diagnostics LED

Connection for control system

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1UBPower supply, DC 24 VBN
2FO1ASafety output, channel 1WH
30VGround, DC 0 VBU
4FO1BSafety output, channel 2BK
5-n.c.GY

Connection for read head

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1H1Data lineBN
3H2Data lineWH
4SHShield-
Dimension drawing
Dimension drawing

Dimension drawings

Dimension drawings
1LED status indication
2Fastening lug with reinforcement plate
3Coding lug
4Cable length 1,000 mm
5Cable length 200 mm

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20

Work area

Repeat accuracy R
according to EN 60947-5-2 <= 10

Electrical connection ratings

Current consumption max. 45 mA
Fusing
external (operating voltage) 0.25 ... 8 A
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 1.5 kV
Operating voltage DC
UB (PELV, see operating instructions) (reverse polarity protected, regulated, residual ripple < 5%) 24 V DC -15% ... +15% (The device tolerates voltage interruptions in the operating voltage, e.g. test pulses, of up to 5 ms. These voltage interruptions are also output on the safety outputs.)
Turn-on time
Safety outputs max. 400 ms
EMC protection requirements according to EN IEC 60947-5-3
Risk time according to EN 60947-5-3 max. 260 ms
Safety class III
Degree of contamination (external, according to EN 60947-1) 3
Safety outputs FO1A / FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Discrepancy time max. 10 ms
Output voltage
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
HIGH U(FO1A) / U(FO1B) UB-1.5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.)
Switching current
per safety output 1 ... 150 mA
Utilization category
DC-13 DC-13 24 V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
Off-state current Ir max. 0.25 mA

Mechanical values and environment

Connection Connecting cable PUR with plug connector M12, 5-pin; pin 5 not used
Degree of protection IP67
Ready delay 1 s
Material
Housing Plastic, PBT
Installation orientation any
Switching frequency max. 1 Hz
Tightening torque max. 1 Nm
Shock and vibration resistance according to EN IEC 60947-5-3
Cable ambient temperature (dynamic) -5 ... +65 °C
Cable ambient temperature (static) -20 ... +65 °C

Reliability values acc. to EN ISO 13849-1

Mission time 20 y
Monitoring of the guard position
Category 4
Performance Level PL e
PFHD 4.5 x 10-9

Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures

In combination with read head CES-A-LMN-SC and actuator CES-A-BMB

Assured operating distances sao min. 3.4 mm (With read head CES-A-LMN-SC and actuator CES-A-BMB)
Assured release distance sar max. 10 mm (With read head CES-A-LMN-SC and actuator CES-A-BMB)
Operating distance 5 mm (With read head CES-A-LMN-SC and actuator CES-A-BMB)
Switching hysteresis 0.05 ... 0.2 mm (With read head CES-A-LMN-SC and actuator CES-A-BMB)

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 2,8 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 119865
Item designation CES-FD-AP-U-01-USI-119865
Gross weight 0,156kg
Customs tariff number 85365019
ECLASS 27-27-24-03 Sicherheitsgerichteter Transponderschalter

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com