KezdőlapProductsTransponder-coded read heads with external evaluationField evaluation unit CES-FDCES-FD-AP-U-01-USI-119865
Field evaluation unit CES-FD-AP-…
- Evaluation of signals in the field
- Connection of CES read heads
- Connection to the ET200s and ET200pro
- Familiar EUCHNER AP interface
- Unicode

Ismertetés
Short circuit monitoring
The switch generates its own clock signal on the output lines FO1A/FO1B. Pay attention to this aspect when connecting to control systems and relays.
Category according to EN ISO 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- Category 4/PL e according to EN ISO 13849-1
Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (FO1A and FO1B) must always be evaluated.
LED indicator
STATE | Status LED |
DIA | Diagnostics LED |
Connection for control system

Dimension drawings

1 | LED status indication |
2 | Fastening lug with reinforcement plate |
3 | Coding lug |
4 | Cable length 1,000 mm |
5 | Cable length 200 mm |
Műszaki adatok
Approvals

Work area
Repeat accuracy R | |
according to EN 60947-5-2 | <= 10 |
Electrical connection ratings
Current consumption | max. 45 mA |
Fusing | |
external (operating voltage) | 0.25 ... 8 A |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Operating voltage DC | |
UB (PELV, see operating instructions) (reverse polarity protected, regulated, residual ripple < 5%) | 24 V DC -15% ... +15% (The device tolerates voltage interruptions in the operating voltage, e.g. test pulses, of up to 5 ms. These voltage interruptions are also output on the safety outputs.) |
Turn-on time | |
Safety outputs | max. 400 ms |
EMC protection requirements | according to EN IEC 60947-5-3 |
Risk time according to EN 60947-5-3 | max. 260 ms |
Safety class | III |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety outputs FO1A / FO1B | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Discrepancy time | max. 10 ms |
Output voltage | |
HIGH U(FO1A) / U(FO1B) | UB-1.5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.) |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Switching current | |
per safety output | 1 ... 150 mA |
Utilization category | |
DC-13 | DC-13 24 V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
Off-state current Ir | max. 0.25 mA |
Mechanical values and environment
Connection | Connecting cable PUR with plug connector M12, 5-pin; pin 5 not used |
Degree of protection | IP67 |
Ready delay | 1 s |
Material | |
Housing | Plastic, PBT |
Installation orientation | any |
Switching frequency | max. 1 Hz |
Tightening torque | max. 1 Nm |
Shock and vibration resistance | according to EN IEC 60947-5-3 |
Cable ambient temperature (dynamic) | -5 ... +65 °C |
Cable ambient temperature (static) | -20 ... +65 °C |
Reliability values acc. to EN ISO 13849-1
Mission time | 20 y |
Monitoring of the guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.5 x 10-9 |
Miscellaneous
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures |
In combination with read head CES-A-LMN-SC and actuator CES-A-BMB
Assured operating distances sao | min. 3.4 mm (With read head CES-A-LMN-SC and actuator CES-A-BMB) |
Assured release distance sar | max. 10 mm (With read head CES-A-LMN-SC and actuator CES-A-BMB) |
Operating distance | 5 mm (With read head CES-A-LMN-SC and actuator CES-A-BMB) |
Switching hysteresis | 0.05 ... 0.2 mm (With read head CES-A-LMN-SC and actuator CES-A-BMB) |
Tartozékok
Connection material
Letöltések
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Instructions
Operating Instructions Field Evaluation Unit CES-FD-AP-… (Unicode/Multicode)
Dok. sz.
Változat
Nyelv
Méret

Operating Instructions Field Evaluation Unit CES-FD-AP-… (Unicode/Multicode)
Dok. sz.
2116267
Változat
06-11/19
Nyelv
Méret
1,1 MB

Operating Instructions Field Evaluation Unit CES-FD-AP-… (Unicode/Multicode)
Dok. sz.
2116267
Változat
06-11/19
Nyelv
Méret
1,1 MB

Betriebsanleitung Feldauswertegerät CES-FD-AP-… (Uni-/Multicode)
Dok. sz.
2116267
Változat
06-11/19
Nyelv
Méret
1,1 MB

Betriebsanleitung Feldauswertegerät CES-FD-AP-… (Uni-/Multicode)
Dok. sz.
2116267
Változat
06-11/19
Nyelv
Méret
1,1 MB
Other Documents
Sales documentation
Ordering data
Rend. sz. | 119865 |
Articlename | CES-FD-AP-U-01-USI-119865 |
Weight | 0,156kg |
Customsclass | 85365019 |