EUCHNER – More than safety.
EUCHNER – More than safety.
KezdőlapProductsTZ1LE024BHA-C1903

TZ1LE024BHA-C1903 (Rend. sz. 082095)

Safety switch TZ, plug connector MR10, mechanical release

  • Auxiliary release on the front
  • Two LED indicators, red and green
  • Plug connector MR10
  • Actuating head fitted left
TZ1LE024BHA-C1903 (Rend. sz. 082095)

Ismertetés

Approach direction

Figure

Figure

Horizontal

Can be adjusted in 90° steps

Solenoid operating voltage and LED function display

  • 24 V AC/DC -15%, +10%

Guard locking type

TZ1Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid.

Switching element

SKFor monitoring the door/actuator position
ÜKFor monitoring the guard locking (built-in solenoid)
2121HSlow-action switching contact 4 NC

Auxiliary release

Is used for releasing the guard locking with the aid of a tool.

Dimension drawing
Dimension drawing
SK:2121H/ÜK:2121H-C1903
SK:2121H/ÜK:2121H-C1903
Switching functions
Switching functions
Electro-mechanical safety switches

Dimension drawing

Dimension drawing
1Auxiliary release cannot be sealed

SK:2121H/ÜK:2121H-C1903

SK:2121H/ÜK:2121H-C1903
Solenoid monitoring
Door monitoring

Switching functions

Switching functions

Műszaki adatok

Engedélyezések

Zulassung EACZulassung DNV GLZulassung c_UL_us LISTED Class 2Zulassung CCC

Mechanikai értékek és környezet

Housing material
Housing Anodized die-cast alloy
Weight
Net 1,2 kg
Ambient temperature -25 ... 80 °C
Degree of protection IP65
Mechanical life 1 x 106
Contact material Silver alloy, gold flashed
Switching principle Slow-action switching contact
Installation orientation Any
Number of door position positively driven contacts 3
Number of guard lock monitoring positively driven contacts 4
Connection
1 x Plug connector BHA10 (9-pin + PE; positively driven NC contact for the door position and positively driven NC contact for the guard lock monitoring connected in series, NC contact for the door position and NC contact for the guard lock monitoring connected in series)
Approach speed max.20 m/min
Actuation frequency max.1200 1/h
Guard locking principle Closed-circuit current principle
Locking force Fmax 2000 N
Locking force FZh 1500 N
Retention force 10 N
Extraction force 30 N
Actuating force 35 N
Insertion depth 52 mm
Lid Red

Elektromos csatlakoztatási értékek

Thermal rated current Ith 4 A (> 70 °C => 2 A)
Utilization category acc. to EN 60947-5-1
AC-15 4A 230V (> 70 °C => 2 A)
DC-13 4A 24V (> 70 °C => 2 A)
Solenoid operating voltage
AC/DC 24 V -15% ... +10%
Short circuit protection according to IEC 60269-1 4A gG (>70°C => 2A gG)
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 1,5 kV
Switching voltage
Min. at 10mA 12 V
Switching current
Min. at 24V 1 mA
Connection rating 10 W
Solenoid duty cycle 100 %
LED indicator Operating voltage corresponds to the solenoid voltage (2 LEDs; green, red)

Megbízhatósági értékek az EN ISO 13849-1 szerint

Control of the guard locking
Category Depending on external control of guard locking (LEDs have the same ground potential as the guard locking solenoid.)
Performance Level Depending on external control of guard locking (LEDs have the same ground potential as the guard locking solenoid.)
PFHD Depending on external control of guard locking (LEDs have the same ground potential as the guard locking solenoid.)
Monitoring of guard locking and the safety guard position
B10D 3 x 106

In combination with Actuator BETAETIGER-Z-GN

Mechanical values and environment

Overtravel 16 mm

In combination with Actuator BETAETIGER-Z-G

Mechanical values and environment

Overtravel 4 mm

Tartozékok

Letöltések

Műszaki támogatás

Műszaki támogatás
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER Magyarország Kft.
+36 1919 0855
info(at)euchner.hu