TP4-4141A024SEM4AS1 (Rend. sz. 088257)

Safety switch TP AS1, plug connector M12 (open-circuit current principle)

  • Auxiliary release on the front
  • Increased horizontal overtravel
  • Optionally without guard lock monitoring
TP4-4141A024SEM4AS1 (Rend. sz. 088257)

Ismertetés

Guard locking types

TP3

Closed-circuit current principle, guard locking by spring force. Release by control of AS-i output 0.

TP4

Open-circuit current principle, guard locking by control of AS-i output 0. Release by spring force.

Control of the guard locking solenoid

The guard locking solenoid is controlled by the control system via AS-Interface bus bit D0. In addition, the 24V connection can be switched safely.

AS-Interface inputs, version AS1

D0, D1

Door monitoring contact SK

D2, D3

Solenoid monitoring contact ÜK

AS-Interface outputs

D0

Guard locking solenoid

D1

LED red

D2

LED green

LED function display

  • The Power LED indicates the operating voltage on the bus.
  • The Fault LED indicates if a fault has been detected on the AS-Interface bus.
  • The green and the red LEDs can be controlled as required by the control system via the bus using bits D1 and D2.

Auxiliary release

This is used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.

Dimension drawing
Dimension drawing
Connector assignment
Connector assignment
Electromechanical safety switches in use

Dimensional drawings

Dimensional drawings
1Auxiliary release
2Locking screw
3LED indicator

Connection examples

Connection examples
View of plug side

Műszaki adatok

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_2/5CCC_2020980305000541_CQC2008010305306207DGUV_ET 20002_ET 20003Asi Interface_56201_

Electrical connection values

ASI operating current max. 45 mA
ASI data in
according to AS-i Safety at Work D0, D1, D2, D3 (see positively driven contact)
ASI data out
LED red D1 (1 = LED on)
ASI auxiliary voltage
IEC 60742, PELV 24 V -15% ... +10%
ASI auxiliary current 300 mA
ASI slave type
according to ASI specification 2.1 ID code: B
ASI voltage 22.5 ... 30 ... 31.6 V
Solenoid duty cycle 100 %

Mechanical values and environment

Approach speed max. 20 m/min
Number of door position positively driven contacts
according to AS-i Safety at Work 1 (D0,D1 / 1 = door closed)
Number of guard lock monitoring positively driven contacts
according to AS-i Safety at Work 1 D2,D3 (1 = locked)
Extraction force 20 N
Actuation frequency max. 1200 1/h
Installation orientation any
Mechanical life 1 x 10⁶
Retention force 10 N
Switching principle Slow-action switching contact
Ambient temperature -20 ... +55 °C
Material
Housing Reinforced thermoplastic
Locking force Fmax 1300 N
Locking force FZh 1000 N

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

B10DMission time
Monitoring of the guard position3x10620 y
Important! Values valid at DC-13 100 mA/24V
Monitoring of guard locking3x10620 y
Important! Values valid at DC-13 100 mA/24V


In combination with actuator ACTUATOR-P-GNT

Horizontal insertion depth 28 mm
Horizontal overtravel 7 mm

In combination with actuator ACTUATOR-P-GT

Horizontal insertion depth 28 mm
Vertical insertion depth 29.5 mm
Horizontal overtravel 2 mm
Vertical overtravel 1.5 mm

Tartozékok

Letöltések

Teljes csomag

Minden fontos dokumentum letöltése egyetlen kattintással.

Tartalom:

  • A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
  • A használati utasítást kiegészítő adatlapok
  • A megfelelőségi nyilatkozat
Teljes csomag letöltése (ZIP, 3,7 MB)

Egyedi dokumentumok

Egyéb dokumentumok

Rendelési adatok

Rend. sz. 088257
Cikk neve TP4-4141A024SEM4AS1
Súly 0,47kg
Vámtarifaszám 85365019000
ECLASS 27-27-26-03 Safety switch with guard control