CES-AR-AES-12 (Rend. sz. 098225)

AR evaluation unit CES-AR-AES-12

  • Central evaluation of an AR switch chain
  • Status of each individual switch can be recognized
  • For switch chains of up to 12 devices
  • Four individual safe relay contacts
  • Category 4/PLe according to EN ISO 13849-1
CES-AR-AES-12 (Rend. sz. 098225)

Ismertetés

Important: A switch chain comprising the following safety switches can be connected to the AR evaluation unit:

CES-AR-C01 / CES-AR-C02 / CES AR-C04 / ESL-AR / CET- AR / CTP-AR

Function

The AR evaluation unit is used to evaluate the individual safety switches in a CES-AR-... switch chain and the safe interruption of a safety circuit.

The unit has two inputs for connection of a CES-AR... switch chain. The safety contacts are switched as a function of the input signals. Downstream parts of the safety circuit can be monitored using a feedback loop.

The switching states of the connected safety switches can be signaled by means of monitoring outputs.

If the actuator on one of the safety switches in the switch chain is moved out of the actuating range, the AR evaluation unit opens its contacts and the corresponding monitoring output is reset.

The system is designed so that failures will not result in the loss of the safety function. The occurrence of failures is detected by cyclic self-monitoring at the latest at the next demand to close the safety contacts.

The system can be started either manually using a start button or automatically.

Category according to EN ISO 13849-1

Due to two redundant safety paths (relay contacts) with 2 internal, monitored normally open contacts per safety path, suitable for:

  • Category 4/PL e according to EN ISO 13849-1

Each safety path is independently safe.

LED indicator

STATE

Status LED

DIA

Diagnostics LED

OUT

Safe state/self-test

Important: The plug-in connection terminals are not included and must be ordered separately.

Dimension drawing
Dimension drawing
Block diagram
Block diagram
Terminal assignment
Terminal assignment

Dimension drawings

Dimension drawings

Connection examples

Connection examples

Connection examples

Connection examples

Műszaki adatok

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/1c_UL_us_E155795_3/2CCC_2020980305000537_CQC2014010303679509

Controls and indicators

LED indicator
DIA LED red: fault display
STATE LED green: device status
OUT LED yellow: AR chain status

Electrical connection ratings

Connection cross-section 0.14 ... 2.5 mm²
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 4 kV
EMC protection requirements according to EN 60947-5-3
Switching delay from state change max. 480 ms (Corresponds to the risk time according to EN 60947-5-3. This is the maximum OFF time for the safety outputs following removal of the actuator.)
Degree of contamination (external, according to EN 60947-1) 2
Y1/Y2
Current via feedback loop 5 ... 8 ... 10 mA
permissible resistance in feedback loop max. 600 Ω
O1 ... O12
Output type Semiconductor outputs, p-switching, short circuit proof
Output current max. 20 mA
Output voltage
LOW 0 ... 1 V DC
HIGH UB - 20% ... UB V DC
OUT AR
Output type Semiconductor output, p-switching, short circuit proof
Output current max. 20 mA
Output voltage
HIGH UB - 20 % ... UB V DC
LOW 0 ... 1 V DC
DIA
Output type Semiconductor output, p-switching, short circuit proof
Output current max. 20 mA
Output voltage
HIGH UB - 20% ... UB V DC
LOW 0 ... 1 V DC
IA, IB
Number of connectible safety switches max. 12
Safety inputs 2 (for CES-AR switch chain)
13/14, 23/24, 33/34, 43/44
Fusing
external (safety circuit) according to EN 60269-1 6 AgG or 6 A circuit breaker (characteristic B or C)
Discrepancy time
between the operating points of both relays max. 25 ms
Switching current
Relay outputs (at switching voltage AC/DC 21 ... 60 V 1 ... 300 mA
Relay outputs (at switching voltage AC/DC 5 ... 30 V) 10 ... 6000 mA
Relay outputs (at switching voltage AC 5 ... 230 V) 10 ... 5000 mA
Utilization category
AC-12 60 V 0.3 A
DC-12 60 V 0.3 A
DC-13 24 V 5 A
AC-15 230 V 5 A
AC-12 30 V 6 A
DC-12 30 V 6 A
Start button S
Response delay
Start button 300 ... 600 ms
Input voltage
HIGH 15 ... UB V DC
LOW 0 ... 2 V DC
Duration of actuation min. 250 ms
Input current
HIGH 5 ... 8 ... 10 mA
Power supply 1
Current consumption
IB (with relay energized) 1200 mA (taking into account the load currents at the monitoring outputs (20 mA each))
Fusing
external (operating voltage UB) 2.5 ... 8 A
Operating voltage DC
UB 24 V DC -10% ... +10% regulated, residual ripple < 5%

Mechanical values and environment

Dimensions 114 x 99 x 45
Number of LED displays 3
Connection plug-in screw terminals, coded
Degree of protection IP20
Ready delay max. 8 s (After the operating voltage is switched on, the relay outputs are switched off and the monitoring outputs are set to LOW level during the ready delay. For visual indication of the delay, the green STATE LED flashes at a frequency of approx. 15 Hz.)
Material
Housing Plastic PA6.6
Atmospheric humidity
not condensing max. 80 % rH
Mounting type Mounting rail 35 mm according to EN 60715
Shock and vibration resistance according to EN IEC 60947-5-3
Ambient temperature
at UB = DC 24 V -20 ... +55 °C
O1 ... O12
Number of monitoring outputs 12
13/14, 23/24, 33/34, 43/44
Number of safety contacts 4 Relay with internally monitored contacts
Mechanical life
Relay 10 x 10⁶
Switching frequency 1 Hz (If the current load is > 100 mA, a switching frequency of 0.1 Hz should not be exceeded as this will affect the mechanical life of the relay contacts.)

Reliability values acc. to EN ISO 13849-1

Number of switching cycles
≤ 0.1 A at 24 V DC max. 720000 1/y
≤ 3 A at 24 V DC max. 107000 1/y
≤ 1 A at 24 V DC max. 540000 1/y
Mission time 20 y (This value is dependent on the number of switching cycles and the switching current.)
Monitoring of the guard position
Category 4 (This value is dependent on the number of switching cycles and the switching current.)
Performance Level PL e (This value is dependent on the number of switching cycles and the switching current.)
PFHD 1.5 x 10-8 (This value is dependent on the number of switching cycles and the switching current.)

Tartozékok

Letöltések

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download complete package (ZIP, 5,9 MB)

Single Documents

Other Documents

Ordering data

Rend. sz. 098225
Articlename CES-AR-AES-12
Weight 0,326kg
Customsclass 85364110