CES-AR-AES-12 (Rend. sz. 098225)

AR evaluation unit CES-AR-AES-12

  • Central evaluation of an AR switch chain
  • Status of each individual switch can be recognized
  • For switch chains of up to 12 devices
  • Four individual safe relay contacts
  • Category 4/PLe according to EN ISO 13849-1
CES-AR-AES-12 (Rend. sz. 098225)

Ismertetés

Important: A switch chain comprising the following safety switches can be connected to the AR evaluation unit:

CES-AR-C01 / CES-AR-C02 / CES AR-C04 / ESL-AR / CET- AR / CTP-AR

Function

The AR evaluation unit is used to evaluate the individual safety switches in a CES-AR-... switch chain and the safe interruption of a safety circuit.

The unit has two inputs for connection of a CES-AR... switch chain. The safety contacts are switched as a function of the input signals. Downstream parts of the safety circuit can be monitored using a feedback loop.

The switching states of the connected safety switches can be signaled by means of monitoring outputs.

If the actuator on one of the safety switches in the switch chain is moved out of the actuating range, the AR evaluation unit opens its contacts and the corresponding monitoring output is reset.

The system is designed so that failures will not result in the loss of the safety function. The occurrence of failures is detected by cyclic self-monitoring at the latest at the next demand to close the safety contacts.

The system can be started either manually using a start button or automatically.

Category according to EN ISO 13849-1

Due to two redundant safety paths (relay contacts) with 2 internal, monitored normally open contacts per safety path, suitable for:

  • Category 4 / PL e according to EN ISO 13849-1

Each safety path is independently safe.

LED indicator

STATE

Status LED

DIA

Diagnostics LED

OUT

Safe state/self-test

Important: The plug-in connection terminals are not included and must be ordered separately.

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples

Connection examples

Connection examples

Műszaki adatok

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/1CCC_2020980305000537_CQC2014010303679509

Operating and display elements

LED display
STATE LED green: device status
OUT LED yellow: AR chain status
DIA LED red: fault display

Electrical connection values

Connection cross section 0.14 ... 2.5 mm²
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 4 kV
EMC protection requirements Acc. to EN 60947-5-3
Switching delay from state change max. 480 ms (Corresponds to the risk time according to EN 60947-5-3. This is the maximum OFF time for the safety outputs following removal of the actuator.)
Degree of contamination (external, according to EN 60947-1) 2
Y1/Y2
Current via feedback loop 5 ... 8 ... 10 mA
permissible resistance in feedback loop max. 600 Ω
O1 ... O12
Output type Semiconductor outputs, p-switching, short circuit proof
Output voltage
LOW 0 ... 1 V DC
HIGH UB - 20% ... UB V DC
Output current max. 20 mA
OUT AR
Output type Semiconductor output, p-switching, short circuit proof
Output voltage
HIGH UB - 20 % ... UB V DC
LOW 0 ... 1 V DC
Output current max. 20 mA
DIA
Output type Semiconductor output, p-switching, short circuit proof
Output voltage
HIGH UB - 20% ... UB V DC
LOW 0 ... 1 V DC
Output current max. 20 mA
IA, IB
Number of connectible safety switches max. 12
Safety inputs 2 (for CES-AR switch chain)
13/14, 23/24, 33/34, 43/44
Fuse
external (safety circuit) according to EN 60269-1 6 AgG or 6 A circuit breaker (characteristic B or C)
Discrepancy time
between the operating points of both relays max. 25 ms
Utilization category
DC-12 60 V 0.3 A
AC-12 30 V 6 A
AC-12 60 V 0.3 A
DC-13 24 V 5 A
DC-12 30 V 6 A
AC-15 230 V 5 A
Switching current
Relay outputs (at switching voltage AC/DC 5 ... 30 V) 10 ... 6000 mA
Relay outputs (at switching voltage AC/DC 21 ... 60 V 1 ... 300 mA
Relay outputs (at switching voltage AC 5 ... 230 V) 10 ... 5000 mA
Start button S
Response delay
Start button 300 ... 600 ms
Duration of actuation min. 250 ms
Input voltage
LOW 0 ... 2 V DC
HIGH 15 ... UB V DC
Input current
HIGH 5 ... 8 ... 10 mA
Power supply 1
Fuse
external (operating voltage UB) 2.5 ... 8 A
Operating voltage DC
UB 24 V DC -10% ... +10% regulated, residual ripple<5%
Current consumption
IB (with relay energized) 1200 mA (taking into account the load currents at the monitoring outputs (20 mA each))

Mechanical values and environment

Dimensions 114 x 99 x 45
Connection type plug-in screw terminals, coded
Number of LED displays 3
Ready delay max. 8 s (After the operating voltage is switched on, the relay outputs are switched off and the monitoring outputs are set to LOW level during the ready delay. For visual indication of the delay, the green STATE LED flashes at a frequency of approx. 15 Hz.)
Atmospheric humidity
not condensing max. 80 % rH
Mounting type Mounting rail 35 mm according to EN 60715
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP20
Ambient temperature
at UB = DC 24 V -20 ... +55 °C
Material
Housing Plastic PA6.6
O1 ... O12
Number of monitoring outputs 12
13/14, 23/24, 33/34, 43/44
Number of safety contacts 4 Relay with internally monitored contacts
Switching frequency 1 Hz (If the current load is>100 mA, a switching frequency of 0.1 Hz should not be exceeded as this will affect the mechanical life of the relay contacts.)
Mechanical life
Relay 10 x 10⁶

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Number of switching cycles
≤ 0.1 A at 24 V DC max. 720000 1/y
≤ 3 A at 24 V DC max. 107000 1/y
≤ 1 A at 24 V DC max. 540000 1/y
Mission time 20 y (This value is dependent on the number of switching cycles and the switching current.)
Monitoring of the guard position
Category 4 (This value is dependent on the number of switching cycles and the switching current.)
Performance Level PL e (This value is dependent on the number of switching cycles and the switching current.)
PFHD 1.5 x 10-8 (This value is dependent on the number of switching cycles and the switching current.)

Tartozékok

Letöltések

Teljes csomag

Minden fontos dokumentum letöltése egyetlen kattintással.

Tartalom:

  • A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
  • A használati utasítást kiegészítő adatlapok
  • A megfelelőségi nyilatkozat
Teljes csomag letöltése (ZIP, 5,9 MB)

Egyedi dokumentumok

Egyéb dokumentumok

Rendelési adatok

Rend. sz. 098225
Cikk neve CES-AR-AES-12
Súly 0,326kg
Vámtarifaszám 85364110
ECLASS 27-27-24-03 Safety-related transponder switch