CES-AH-C03-AH-SM-106300 (Rend. sz. 106300)
Válasszon tartalmat
Non-contact safety switch CES-AH-C03-...
- Safety switch with integrated evaluation electronics
- Load currents of 3.5 A can be switched directly
- 2 safety outputs (semiconductor outputs)
- Category 3 / PL d according to EN ISO 13849-1
- With plug connector M23
- Approach direction A (not adjustable)
- Unicode

Ismertetés
Unicode evaluation
Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in.
Only the last actuator taught-in is detected.
Category according to EN ISO 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- Category 3 / PL d according to EN ISO 13849-1
Each safety path is independently safe.
LED indicator
STATE | Status LED |
DIA | Diagnostics LED |




Dimensional drawings

1 | Active face |
2 | shield spring |
3 | LED status indication |
Connection examples

Connection examples

Connection examples

Műszaki adatok
Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | 10 % |
Operating and display elements
LED display | 2 STATE (green) and DIA (red) |
Electrical connection values
Fuse | |
external (operating voltage, +LA and +LB) | 0.25 ... 10 A |
Rated insulation voltage Ui | 75 V |
Rated impulse voltage Uimp | 1.5 kV |
Operating voltage DC | |
UB | 20 ... 28 V DC reverse polarity protected, regulated, residual ripple<5%, PELV |
Discrepancy time | max. 50 ms |
Turn-on time | |
Safety outputs LA / LB | max. 400 ms |
EMC protection requirements | Acc. to EN IEC 60947-5-3 |
Off-state current Ir | max. 0.5 mA |
Risk time according to EN 60947-5-3 | max. 250 ms |
Safety class | III |
Current consumption | |
no load on outputs | max. 150 mA |
Degree of contamination (external, according to EN 60947-1) | 3 |
Time delay | |
In the fault state | 5 s (The switch remains in the fault state for this time before a reset is performed.) |
Power supply outputs | |
Power supply output load | |
U(+LA)/U(+LB) | 20 ... 28 V DC (Power supply same UB, same GND potential.) |
Safety output LA | |
Output type | Semiconductor output, p-switching, short circuit-proof |
Output voltage | |
HIGH U(LA) | U(+LA) - 1.5 ... U(+LA) V DC (Values at a switching current of 3.5 A without taking into account the cable lengths.) |
LOW U(LA) | 0 ... 4 V DC |
rated conditional short-circuit current | 100 A |
Utilization category | |
DC-13 | 24V 3.5A (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
Switching current | 30 ... 3500 mA |
Test pulse duration | max. 6 ms (With series connection, the value increases according to the number of switches used.) |
Test pulse interval | min. 10000 ms |
Safety output LB | |
Output type | Semiconductor output, p-switching, short circuit-proof |
Output voltage | |
HIGH U(LB) | U(+LB) - 1.5 ... U(+LB) V DC (Values at a switching current of 3.5 A without taking into account the cable lengths.) |
LOW U(LB) | 0 ... 4 V DC |
rated conditional short-circuit current | 100 A |
Utilization category | |
DC-13 | 24V 3.5A (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
Switching current | 30 ... 3500 mA |
Test pulse duration | max. 6 ms (With series connection, the value increases according to the number of switches used.) |
Test pulse interval | min. 10000 ms |
Start input | |
Input voltage | |
HIGH | 8 ... UB V DC |
LOW | 0 ... 2 V DC |
Mechanical values and environment
Dimensions | 40 x 40 x 171 |
Connection type | M23 plug connector, 9-pin |
Tightening torque | |
Fixing screws | max. 1 Nm |
Ready delay | max. 3 s (After the operating voltage is switched on, the semiconductor outputs are switched off during the ready delay.) |
Installation orientation | any |
Switching frequency | max. 1 Hz |
Storage temperature | -25 ... 70 °C |
Mounting distance | |
between switches | min. 80 mm |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP67 |
Ambient temperature | |
at I(LA) / I(LB)>3 A | -20 ... 55 °C (+70 °C at I(LA) / I(LB)<3 A) |
Dwell time | min. 0.5 s (The dwell time of an actuator inside and outside the actuating range must be at least 0.5 s to ensure safe detection of internal faults in the evaluation unit (self-monitoring).) |
Material | |
Housing | Plastic, PBT |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Monitoring of the guard position | PL d | - | 1.03x10-7 | 3 | 20 y |
In combination with actuator CES-A-BBA-071840, CES-A-BCA
Actuator distance s | |
Minimum distance for side approach direction | min. 4 mm (Minimum distance to prevent switching on in the side lobe of the read head.) |
Switch-on distance | 20 mm |
Secured switch-off distance sar | max. 40 mm |
Secured switching distance sao | min. 18 mm (for surface mounting of the actuator) |
Switching hysteresis | 2 ... 3 mm (for surface mounting of the actuator) |
In combination with actuator CES-A-BRN-100251
Actuator distance s | |
Minimum distance for side approach direction | min. 6 mm (Minimum distance to prevent switching on in the side lobe of the read head.) |
Switch-on distance | 27 mm |
Secured switch-off distance sar | max. 75 mm |
Secured switching distance sao | min. 20 mm (The values apply to surface mounting of the actuator on steel.) |
Switching hysteresis | 3 mm (The values apply to surface mounting of the actuator on steel.) |
In combination with actuator CES-A-BPA-098775
Actuator distance s | |
Minimum distance for side approach direction | min. 6 mm (Minimum distance to prevent switching on in the side lobe of the read head.) |
Switch-on distance | 22 mm (for surface mounting on aluminum; in a metal-free environment, the typical operating distance increases to 30 mm) |
Secured switch-off distance sar | max. 58 mm |
Secured switching distance sao | min. 18 mm |
Switching hysteresis | 1 ... 2 mm |
Tartozékok
Letöltések
Teljes csomag
Minden fontos dokumentum letöltése egyetlen kattintással.
Tartalom:
- A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
- A használati utasítást kiegészítő adatlapok
- A megfelelőségi nyilatkozat
Teljes csomag letöltése (ZIP, 2,3 MB)
Egyedi dokumentumok
Egyéb dokumentumok
Approvals and certificates
WEEE
Dok. sz.
Változat
Nyelv
Méret

WEEE
Dok. sz.
ECO20001806
Változat
Nyelv
Méret
0,1 MB
Sales documents
Rendelési adatok
Rend. sz. | 106300 |
Cikk neve | CES-AH-C03-AH-SM-106300 |
Súly | 0,45kg |
Vámtarifaszám | 85365019000 |
ECLASS | 27-27-24-03 Safety-related transponder switch |