Non-contact safety switch CES-AH-C03-...
- Safety switch with integrated evaluation electronics
- Load currents of 3.5 A can be switched directly
- 2 safety outputs (semiconductor outputs)
- Category 3 / PL d according to EN ISO 13849-1
- With plug connector M23
- Approach direction A (not adjustable)
- Unicode

Ismertetés
Unicode evaluation
Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in.
Only the last actuator taught-in is detected.
Category according to EN ISO 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- Category 3/PL d according to EN ISO 13849-1
Each safety path is independently safe.
LED indicator
STATE | Status LED |
DIA | Diagnostics LED |
Attention:
The actuating range may vary depending on the substrate material and installation situation.
Typical actuating range
(only in combination with actuators CES-A-BBA and CES-A-BCA)

(Only in combination with actuator CES-A-BPA)





Dimension drawings

1 | Active face |
2 | Shield spring |
3 | LED status indication |
Connection examples

Connection examples

Connection examples

Műszaki adatok
Work area
Repeat accuracy R | |
according to EN 60947-5-2 | <= 10 |
Controls and indicators
LED indicator | 2 STATE (green) and DIA (red) |
Electrical connection ratings
Current consumption | |
no load on outputs | max. 150 mA |
Fusing | |
external (operating voltage, +LA and +LB) | 0.25 ... 10 A |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Discrepancy time | max. 50 ms |
Operating voltage DC | |
UB | 20 ... 28 V DC reverse polarity protected, regulated, residual ripple < 5%, PELV |
Turn-on time | |
Safety outputs LA / LB | max. 400 ms |
EMC protection requirements | according to EN IEC 60947-5-3 |
Off-state current Ir | max. 0.5 mA |
Risk time according to EN 60947-5-3 | max. 250 ms |
Safety class | III |
Degree of contamination (external, according to EN 60947-1) | 3 |
Time delay | |
In the fault state | 5 s (The switch remains in the fault state for this time before a reset is performed.) |
Power supply outputs | |
Power supply output load | |
U(+LA)/U(+LB) | 20 ... 28 V DC (Power supply same UB, same GND potential.) |
Safety output LA | |
Output type | Semiconductor output, p-switching, short circuit-proof |
rated conditional short-circuit current | max. 100 A |
Output voltage | |
HIGH U(LA) | U(+LA) - 1.5 ... U(+LA) V DC (Values at a switching current of 3.5A without taking into account the cable lengths.) |
LOW U(LA) | 0 ... 4 V DC |
Switching current | 30 ... 3500 mA |
Utilization category | |
DC-13 | 24V 3.5A (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
Test pulses | max. 6 ms (With series connection, the value increases according to the number of switches used.) |
Test pulse interval | min. 10000 ms |
Safety output LB | |
Output type | Semiconductor output, p-switching, short circuit-proof |
rated conditional short-circuit current | max. 100 A |
Output voltage | |
HIGH U(LB) | U(+LB) - 1.5 ... U(+LB) V DC (Values at a switching current of 3.5A without taking into account the cable lengths.) |
LOW U(LB) | 0 ... 4 V DC |
Switching current | 30 ... 3500 mA |
Utilization category | |
DC-13 | 24V 3.5A (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
Test pulses | max. 6 ms (With series connection, the value increases according to the number of switches used.) |
Test pulse interval | min. 10000 ms |
Start input | |
Input voltage | |
HIGH | 8 ... UB V DC |
LOW | 0 ... 2 V DC |
Mechanical values and environment
Dimensions | 40 x 40 x 171 |
Connection | M23 plug connector, 9-pin |
Degree of protection | IP67 |
Ready delay | max. 3 s (After the operating voltage is switched on, the semiconductor outputs are switched off during the ready delay.) |
Material | |
Housing | Plastic, PBT |
Installation orientation | any |
Switching frequency | max. 1 Hz |
Tightening torque | |
Fixing screws | max. 1 Nm |
Mounting distance | |
between 2 switches or actuators | min. 80 mm |
Shock and vibration resistance | according to EN IEC 60947-5-3 |
Ambient temperature | |
at I(LA) / I(LB) > 3 A | -20 ... +55 °C (+70 °C at I(LA) / I(LB) < 3 A) |
Dwell time | min. 0.5 s (The dwell time of an actuator inside and outside the actuating range must be at least 0.5 s to ensure safe detection of internal faults in the evaluation unit (self-monitoring).) |
Reliability values acc. to EN ISO 13849-1
Mission time | 20 y |
Monitoring of the guard position | |
Category | 3 |
Performance Level | PL d |
PFHD | 1.03 x 10-7 |
In combination with actuator CES-A-BRN-100251
Actuator distance s | |
for side approach | min. 6 mm (Minimum distance to prevent switching on in the side lobe of the read head.) |
Assured operating distances sao | min. 20 mm (The values apply to surface mounting of the actuator on steel.) |
Assured release distance sar | max. 75 mm |
Operating distance | 27 mm |
Switching hysteresis | 3 mm (The values apply to surface mounting of the actuator on steel.) |
In combination with actuator CES-A-BPA-098775
Actuator distance s | |
for side approach | min. 6 mm (Minimum distance to prevent switching on in the side lobe of the read head.) |
Assured operating distances sao | min. 18 mm |
Assured release distance sar | max. 58 mm |
Operating distance | 22 mm (for surface mounting on aluminum; in a non-metallic environment, the typical operating distances increase to 30 mm.) |
Switching hysteresis | 1 ... 2 mm |
In combination with actuator CES-A-BBA-071840, CES-A-BCA
Actuator distance s | |
for side approach | min. 4 mm (Minimum distance to prevent switching on in the side lobe of the read head.) |
Assured operating distances sao | min. 18 mm (The values apply to surface mounting of the actuator.) |
Assured release distance sar | max. 40 mm |
Operating distance | 20 mm |
Switching hysteresis | 2 ... 3 mm (The values apply to surface mounting of the actuator.) |
Tartozékok
Letöltések
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Ordering data
Rend. sz. | 106300 |
Articlename | CES-AH-C03-AH-SM-106300 |
Weight | 0,45kg |
Customsclass | 85365019 |