MSC-CE-AH-FO4SO8-122705 (Rend. sz. 122705)

Expansion module MSC-CE

  • Output expansion
  • 4 control inputs
  • 4 single-channel high-current semiconductor outputs (up to PL e, category 4)
  • 8 monitoring outputs
  • Compact housing with width of only 22.5mm
  • Simple diagnostics via LED displays
  • Plug-in screw terminals (expansion plug included)
MSC-CE-AH-FO4SO8-122705 (Rend. sz. 122705)

Ismertetés

Inputs and outputs

  • 4 control inputs for starting/restarting relay outputs or for external device monitoring (EDM)

  • 4 single-channel/2 dual-channel semiconductor outputs with up to 2 A output current (up to PL e, category 4)

  • 8 monitoring outputs programmed via the EUCHNER Safety Designer software
Three settings are available for the safe semiconductor outputs (configuration via the EUCHNER Safety Designer software):
  • 4 single-channel outputs

  • 2 dual-channel outputs

  • 1 dual-channel and 2 single-channel outputs

Scope of delivery

  • The expansion plug (order no. 121308) is included with the expansion module

Accessories

  • Plug-in screw terminals (order no. 121321) must be ordered separately

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
MSC: Safe control system MSC

Dimensional drawings

Dimensional drawings
1Page A
2Page B

Connection examples

Connection examples

Műszaki adatok

Approvals

EAC_RU C-DE.MO05.B.00971/20TUEV Süd München_Z10 040393 0030 Rev.01c_UL_us_E353660_UL_us_E467239

Electrical connection values

Connection cross section 0.5 ... 2.5 mm² (Screw terminal)
Outputs
NumberTypeFunctionFootnote
2Semiconductor outputs, p-switching, short circuit-proofSafety outputs (OSSD)(usable as 4 single-channel OSSDs)
8Semiconductor outputs, p-switchingMonitoring outputs, programmable(according to EN 61131-2)
Output voltage
Safety outputs (OSSD) UB-0.75 ... UB V DC HIGH
Safety outputs (OSSD) 0 ... 2 V DC LOW
Output current
Safety outputs (OSSD) 0 ... 2000 mA
Monitoring outputs, programmable max. 100 mA
Operating voltage DC
UB 24 V DC -20% ... +20% PELV (according to EN 60204-1)
Inputs
NumberTypeFunctionFootnote
2Semiconductor outputs, p-switchingfor node selection("Type 2" according to EN 61131-2)
4Semiconductor outputs, p-switchingFeedback loop monitoring (EDM)(according to EN 61131-2)
Input voltage
Test pulse duration
Safety outputs (OSSD) 0.1 ms
Test outputs 0.2 ms
Test pulse interval 600 ms
Overvoltage category according to IEC EN 60664-1 II
Power dissipation max. 4 W
Degree of contamination according to EN 60664-1 2

Mechanical values and environment

Dimensions 108 x 22.5 x 114.5 (Including screw terminals)
Connection type Plug-in screw terminal (Terminals not included)
Storage temperature -20 ... +85 °C
Cable length max. 100 m (with length above 50 m, cross-section>use 1 mm²)
Atmospheric humidity 10 ... 95 % rH
Mounting type 35 mm mounting rail (according to EN 60715)
Degree of protection IP20
Ambient temperature -10 ... +55 °C
Material
Housing Polyamide

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y
Category 4
Performance Level PL e
PFHD 8.56 E-09 1/h (according to IEC 61508:2010)

Letöltések

Teljes csomag

Minden fontos dokumentum letöltése egyetlen kattintással.

Tartalom:

  • A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
  • A használati utasítást kiegészítő adatlapok
  • A megfelelőségi nyilatkozat
Teljes csomag letöltése (ZIP, 57,9 MB)

Egyedi dokumentumok

Egyéb dokumentumok

Rendelési adatok

Rend. sz. 122705
Cikk neve MSC-CE-AH-FO4SO8-122705
Súly 0,213kg
Vámtarifaszám 85364110