Non-contact safety switches CES-I-AR-.-C14-…, with cable end sleeves
- Safety switch with integrated evaluation electronics
- Safety switch CES-C04 encapsulated in epoxy resin
- Tested for material resistance in accordance with Ecolab specifications
- Up to 20 switches in series
- 2 safety outputs (semiconductor outputs)
- Category 4 / PL e according to EN ISO 13849-1
- Three active faces
- Connecting cable PUR, 20 m, with cable end sleeves
- Multicode
- Monitoring output OD

Ismertetés
Attention:
The actuating range may vary depending on the substrate material and installation situation.
Typical actuating range
(only in combination with actuator CES-A-BBN)

For a side approach direction for the actuator and safety switch, a minimum distance of s = 10 mm must be maintained so that the actuating range of the side lobes is not entered.
Multicode evaluation
Every suitable actuator is detected by the switch.
Category according to EN 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- Category 4/PL e according to EN 13849-1
Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated.
LED indicator
STATE | Status LED |
DIA | Diagnostics LED |
Terminal assignment
Designation | Function | Connecting cable conductor coloring |
---|---|---|
FI1B | Enable input for channel 2 | WH |
UB | Power supply, DC 24 V | BN |
FO1A | Safety output, channel 1 | GN |
FO1B | Safety output, channel 2 | YE |
OD | Monitoring output | GY |
FI1A | Enable input for channel 1 | PK |
0V | Ground, DC 0 V | BU |
RST | Reset input | RD |


Dimension drawings

1 | Active face |
2 | LED status indication |
3 | Cable end sleeve on cable end |
Connection examples

Műszaki adatok
Approvals



Work area
Repeat accuracy R | |
according to EN 60947-5-2 | <= 10 |
Electrical connection ratings
Current consumption | max. 35 mA (without taking into account the load currents on the monitoring output and the safety outputs) |
Fusing | |
external (operating voltage) | 0.25 ... 8 A |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Operating voltage DC | |
UB | 24 V DC -15% ... +15% regulated, residual ripple < 5%, PELV |
Turn-on time | |
Safety outputs | max. 400 ms |
EMC protection requirements | according to EN IEC 60947-5-3 |
Risk time according to EN 60947-5-3 | max. 260 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 5 ms |
Safety class | III |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring output OD | |
Output type | Semiconductor output, p-switching, short circuit-proof |
Output voltage | 0.8 x UB ... UB V DC |
Switching current | max. 50 mA |
Safety outputs FO1A / FO1B | |
Output type | 2 semiconductor outputs, p-switching, short circuit-proof |
rated conditional short-circuit current | 100 A |
Discrepancy time | max. 10 ms |
Output voltage | |
LOW U (FO1A) / U (FO1B) | 0 ... 1 V DC (Values at a switching current of 50 mA without taking into account the cable lengths.) |
HIGH U (FO1A) / U (FO1B) | UB-1.5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.) |
Switching current | |
per safety output | 1 ... 200 mA |
Utilization category | |
DC-13 | 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
Off-state current Ir | max. 0.25 mA |
Test pulses | max. 1.0 ms (Applies to a load with C <= 30 nF and R <= 20 kohm) |
Test pulse interval | min. 140 ms |
Mechanical values and environment
Connection | Connecting cable PUR, length 20m |
Degree of protection | IP65/IP67/IP69/IP69K |
Ready delay | 10 s |
Material | |
Housing | 2-component epoxy resin |
Dynamic bending radius | 10 x cable diameter |
Static bending radius | 5 x cable diameter |
Installation orientation | any |
Switching frequency | max. 1 Hz |
Tightening torque | |
Fixing screws | 2 Nm |
Mounting distance | |
between 2 switches or 2 actuators | min. 80 mm |
Mounting type | Surface mounting on metal |
Shock and vibration resistance | according to EN IEC 60947-5-3 |
Ambient temperature | |
at UB = DC 24 V | 0 ... +65 °C |
Reliability values acc. to EN ISO 13849-1
Mission time | 20 y |
Monitoring of the guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10-9 |
In combination with actuator CES-A-BBN-C14-160441
Assured operating distances sao | |
Installation position A / in z direction | max. 10 mm ALU |
Installation position D / in z direction | max. 6 mm ALU |
Installation position D / in z direction | max. 5 mm PVC |
Installation position A / in z direction | max. 11 mm PVC |
Assured release distance sar | |
Installation position D / in y direction | max. 68 mm |
Installation position A / in y direction | max. 72 mm |
Installation position D / in x/z direction | max. 58 mm |
Installation position A / in x/z direction | max. 64 mm |
Operating distance | |
Installation position A / in z direction | max. 24 mm ALU |
Installation position D / in z direction | max. 18 mm PVC |
Installation position A / in z direction | max. 22 mm PVC |
Installation position D / in z direction | max. 23 mm ALU |
Tartozékok
Letöltések
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents








Other Documents

Homologation
Homologación
EAC
Homologação
Omologazione
认证
認可
승인
Сертификат
Atest
Engedély
Разрешително
Godkendelse
Heakskiit
Hyväksyntä
Έγκριση
Odobrenje
Atļauja
Patvirtinimas
Goedkeuring
Godkjenning
Dopuszczenie
Godkännande
Dovoljenje
Povolenie
Onay
Дозвіл

Homologation
Homologación
c UL us
Homologação
Omologazione
认证
認可
승인
Сертификат
Atest
Engedély
Разрешително
Godkendelse
Heakskiit
Hyväksyntä
Έγκριση
Odobrenje
Atļauja
Patvirtinimas
Goedkeuring
Godkjenning
Dopuszczenie
Godkännande
Dovoljenje
Povolenie
Onay
Дозвіл


Ordering data
Rend. sz. | 162596 |
Articlename | CES-I-AR-M-C14-U20-162596 |
Weight | 0,725kg |
Customsclass | 85365019 |