CTP-L1-AR-U-HA-AEE-SH-163538 (Rend. sz. 163538)

Safety switch with guard locking CTP-AR EXTENDED, RFID, plug connector M23 (RC18), EMERGENCY STOP, escape release

  • Extended (illuminated pushbutton, selector switch, EMERGENCY STOP)
  • Closed-circuit current principle
  • Unicode
  • Monitoring output door position OD
  • Monitoring output diagnosis OI
  • Plug connector(s) M23 (RC18), 19-pole
  • Escape release
CTP-L1-AR-U-HA-AEE-SH-163538 (Rend. sz. 163538)

Ismertetés

Version Extended

The Extended version includes additional control and display elements.

Approach direction

Horizontal

Can be adjusted in 90° steps

Guard locking principle

Power to unlock: On a guard with guard locking based on the closed-circuit current principle, the guard is locked by spring force until the guard locking solenoid is supplied with power. Unlocking is by solenoid force. The term mechanical guard locking is also used.

Unicode evaluation

Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in.

Only the last actuator taught-in is detected.

Escape release

This is used for manual release of guard locking from the danger zone without tools.

Terminal assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1IMPSolenoid operating voltage, 24 V DCVT
2FI1AEnable input, channel ARD
3FI1BEnable input, channel BGY
4FO1ASafety outputs channel A

RD/BU
5FO1BSafety outputs channel B

GN
6UBOperating voltage electronics, controls/indicators 24 V DCBU
7RSTReset inputGY/PK
8ODDoor position monitoring outputGN/WH
9OIDiagnostic monitoring outputYE/WH
10S1.A1EMERGENCY STOP (channel A contact 1)GY/WH
11S1.A2EMERGENCY STOP (channel A contact 2)BK
12FEFunctional earth (must be connected to meet the EMC requirements)GN/YE
13S1.B1EMERGENCY STOP (channel B contact 1)PK
14S1.B2EMERGENCY STOP (channel B contact 2)BN/GY
15S2Pushbutton 2 (illuminated)BN/YE
16H2LED 2BN/GN
17S3Pushbutton 3 (illuminated)WH
18H3LED 3YE
190 VOperating voltage electronics, controls/indicators and magnet 0V DCBN

Lens set

The color of the pushbuttons can be selected using the color cover set included (5 colors). Item no.: 120344 (see Accessories)

Accessories required

Actuator is not included.

The safety switch can only be actuated in conjunction with the actuators provided for this purpose.

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings
1LEDs
2Emergency stop
3Auxiliary release
4Pushbutton 2 illuminated
5Pushbutton 3 illuminated

Connection examples

Connection examples

Műszaki adatok

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/11FCC_2AJ58-05_

Workspace

Repeat accuracy R 10 %

Operating and display elements

ItemColorExtrasSlide-in labelNote slide-in labelSwitching elementVersionNumberDesignation1LED
12 PDEmergency stop
21NOSelector switch, illuminated
31NOIlluminated pushbutton

Electrical connection values

Fuse
external (solenoid operating voltage IMP) 0.5 ... 8 A
external (operating voltage UB) 0.25 ... 8 A
Power consumption 6 W
Rated insulation voltage Ui 50 V
Rated impulse voltage Uimp 0.5 kV
Operating voltage DC
UUB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
EMC protection requirements Acc. to EN IEC 60947-5-3
Utilization category
DC-13 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Solenoid operating voltage DC
UIMP 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV
Solenoid duty cycle 100 %
Risk time according to EN 60947-5-3 max. 260 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 5 ms
Switching load
according to UL 24V DC, Class 2 (alternatively, see operating instructions)
Safety class III
Current consumption
IIMP 400 mA
IUB 40 mA
Test pulse duration max. 1.0 ms (Applies to a load with C<= 30nF and R<= 20kOhm)
Test pulse interval min. 140 ms
Degree of contamination (external, according to EN 60947-1) 3
Controls and indicators
Operating voltage UB V
Operating current 1 ... 50 mA
Power supply
LED 24 V
Current consumption
LED 10 mA
Emergency stop
Breaking capacity max. 0.25 W
Switching voltage 5 ... 24 V
Switching current 1 ... 100 mA
Monitoring output OD, OI
Output type p-switching, short circuit-proof
Output voltage 0.8xUB ... UB V DC
Switching current 1 ... 50 mA
Safety outputs FO1A/FO1B
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Output voltage
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
HIGH U(FO1A) / U(FO1B) UB-1.5 ... UB V DC
Discrepancy time
both safety outputs max. 10 ms Acc. to EN IEC 60947-5-3
Turn-on time max. 400 ms
Off-state current Ir max. 0.25 mA
Switching current
per safety output FO1A / FO1B 1 ... 150 mA

Mechanical values and environment

Anfahrgeschwindigkeit max. 20 m/min
Connection type 1 plug connector M23, 19-pin, RC18
Extraction force 20 N
Ready delay 8 s
Actuating force 10 N
Installation orientation any
Switching frequency max. 0.5 Hz
Storage temperature -25 ... 70 °C
Mechanical life 1 x 10⁶
Overtravel 5 mm
Retention force 20 N
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (In the inserted and screwed tight state)
Ambient temperature
at UB = 24 V DC -20 ... 55 °C
Material
Safety switch housing Reinforced thermoplastic
Switch head cover Die-cast zinc
Locking force Fmax 3900 N
Locking force FZh 3000 N (Fzh = Fmax/1.3, depending on the actuator used)
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Guard lock monitoringPL e-4.1x10-9420 y


B10DMission time
Emergency stop0.13x10620 y


PLMaximum SILCategoryMission time
Control of guard lockingDepending on external control of guard locking20 y


Miscellaneous

Notices for UL approval Operation only with UL Class 2 power supply or equivalent measures; see operating instructions
Additional feature
Escape release actuated by pushing
incl. lens set, ID no. 120344

Tartozékok

Letöltések

Teljes csomag

Minden fontos dokumentum letöltése egyetlen kattintással.

Tartalom:

  • A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
  • A használati utasítást kiegészítő adatlapok
  • A megfelelőségi nyilatkozat
Teljes csomag letöltése (ZIP, 18,7 MB)

Egyedi dokumentumok

Dok. sz.
Változat
Nyelv
Méret
Dok. sz. 2123041
Operating instructions Transponder-Coded Safety Switch With Guard Locking CTP-AR Unicode/Multicode
Dok. sz.
2123041
Változat
08-01/21
Nyelv
Méret
4,7 MB
Dok. sz. 2123041
Mode d'emploi Interrupteur de sécurité à codage par transpondeur avec interverrouillage CTP-AR uni-/multicode
Dok. sz.
2123041
Változat
08-01/21
Nyelv
Méret
4,7 MB
Dok. sz. 2123041
Manual de instrucciones Interruptor de seguridad con codificación por transponder con bloqueo CTP-AR Unicode/Multicode
Dok. sz.
2123041
Változat
08-01/21
Nyelv
Méret
4,7 MB
Dok. sz. 2123041
Betriebsanleitung Transpondercodierter Sicherheitsschalter mit Zuhaltung CTP-AR Uni-/Multicode
Dok. sz.
2123041
Változat
08-01/21
Nyelv
Méret
4,7 MB
Dok. sz. 2123041
Istruzioni di impiego Finecorsa di sicurezza con codifica a transponder con meccanismo di ritenuta CTP-AR Uni-/Multicode
Dok. sz.
2123041
Változat
08-01/21
Nyelv
Méret
4,7 MB
Dok. sz. 2123041
操作指示書トランスポンダー型コード化安全スイッチ ガードロック内蔵CTP-AR ユニコード/マルチコード
Dok. sz.
2123041
Változat
08-01/21
Nyelv
Méret
4,9 MB
Dok. sz. 2123041
사용 설명서 트랜스폰더 코딩형 안전 스위치 가드 잠금 기능 있음 CTP-AR 유니코드/멀티코드
Dok. sz.
2123041
Változat
08-01/21
Nyelv
Méret
5,1 MB
Dok. sz. 2123041
Návod k použití Bezpečnostní spínač s kódovaným transpondérem CTP-AR Unicode/Multicode
Dok. sz.
2123041
Változat
08-01/21
Nyelv
Méret
4,9 MB
Dok. sz. 2123041
Instrukcja obsługi Wyłącznik bezpieczeństwa kodowany transponderowo z blokadą CTP-AR Unicode/Multicode
Dok. sz.
2123041
Változat
08-01/21
Nyelv
Méret
4,9 MB

Egyéb dokumentumok

Rendelési adatok

Rend. sz. 163538
Cikk neve CTP-L1-AR-U-HA-AEE-SH-163538
Súly 0,9kg
Vámtarifaszám 85371098
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking