EUCHNER – More than safety.
EUCHNER – More than safety.
AnasayfaProductsTransponder-coded key systems EKS and CKSElectronic-Key-System EKSElectronic-Key adapter with data interface for safe applications EKS FSA compact

EKS-A-IIXA-G01-ST02/03/04 (Sip. No. 106306)

Electronic-Key adapter with PROFINET interface, version FSA

  • Electronic-Key adapter with PROFINET IO interface
  • Read/write system
  • Remote mounting
  • Electronic-Key adapter and electronics in one housing
  • Reliable retention of the Electronic-Key, even if there is heavy vibration
  • Transfers the data from the Electronic-Key to a control system for processing
  • Connection to PLC
  • PROFINET protocol, cyclic data transfer to control system
  • Interfacing via GSDML file
  • Various options for address assignment, also using DIP switches
  • Version FSA (For Safety Applications)
EKS-A-IIXA-G01-ST02/03/04 (Sip. No. 106306)

Açıklama

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
EKS FSA - Selection of safe operating mode up to PL e with touch panel

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples

Teknik Veriler

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E240367_X1/A1ProfiNET_Z10134FCC_EKS kompakt_2AJ58-15c_UL_us_E240367_X1/A1

Operating and display elements

LED display
Green operational
Red Error
Yellow Key in actuating range

Electrical connection values

Power supply
Operating voltage DC 20 ... 24 ... 28 V DC
Current consumption max. 150 mA
PROFINET interface
Connecting cable min. 2x2 twisted pair copper cable shielded, min. Cat. 5
Parameters for the outputs LA and LB
Connection cross section 0.14 ... 1.5 mm² (plug-in screw terminal, 2 x 2-pin)
Discrepancy time 200 ms Difference time between outputs (LB first) (If access on the interface takes place during the insertion or removal of the Electronic-Key, the simultaneity time can be more than 200 ms.)
Utilization category
AC-15 24 V 50 mA
DC-13 24 V 50 mA
AC-12 24 V 50 mA
DC-12 24 V 50 mA
Switching voltage 24 ... 30 V
Switching current 1 ... 10 ... 50 mA with short circuit protection max. 100 times

Mechanical values and environment

Installation orientation on the front
Mounting cut-out according to DIN IEC 61554 33x68 mm
Degree of protection
in mounted condition (only access side) IP67
Ambient temperature 0 ... +55 °C
Material
Housing PA6-GF30, gray
PROFINET interface
Connection type
RJ-45 socket
star topology wiring

Miscellaneous

Parameters for the outputs LA and LB
Additional feature
35 Resistance in switched-on state in ohm
max. 1 Capacitive load per output in µF

Interface

PROFINET interface
Data protocol PROFINET
Data rate 10/100 Mbit/s
Date interface Ethernet (IEEE 802.3)

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 7,7 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 106306
Makale adı EKS-A-IIXA-G01-ST02/03/04
Ağırlık 0,194kg
Gümrük sınıfı 85365019000
ECLASS 27-39-90-90 Property, access monitor (other, unspecified)