KezdőlapProductsTransponder-coded key systems EKS and CKSElectronic-Key-System EKSElectronic-Key adapter with data interface for safe applications EKS FSA compactEKS-A-IIXA-G01-ST02/03/04
Electronic-Key adapter with PROFINET interface, version FSA
- Electronic-Key adapter with PROFINET IO interface
- Read/write system
- Remote mounting
- Electronic-Key adapter and electronics in one housing
- Reliable retention of the Electronic-Key, even if there is heavy vibration
- Transfers the data from the Electronic-Key to a control system for processing
- Connection to PLC
- PROFINET protocol, cyclic data transfer to control system
- Interfacing via GSDML file
- Various options for address assignment, also using DIP switches
- Version FSA (For Safety Applications)

Ismertetés



Dimension drawings

Connection examples

Műszaki adatok
Approvals




Controls and indicators
LED indicator | |
red | Error |
yellow | Key in actuating range |
green | operational |
Electrical connection ratings
Power supply | |
Current consumption | max. 150 mA |
Operating voltage DC | 20 ... 24 ... 28 V DC |
PROFINET interface | |
Connecting cable | min. 2x2 twisted pair copper cable shielded, min. cat. 5 |
Parameters for the outputs LA and LB | |
Connection cross-section | 0.14 ... 1.5 mm² (plug-in screw terminal, 2 x 2-pin) |
Discrepancy time | 200 ms Difference time between outputs (LB first) (If access on the interface takes place during the insertion or removal of the Electronic-Key, the simultaneity time can be more than 200 ms.) |
Switching current | 1 ... 10 ... 50 mA with short circuit protection max. 100 times |
Switching voltage | 24 ... 30 V |
Utilization category | |
DC-12 | 24V 50mA |
DC-13 | 24V 50mA |
AC-15 | 24V 50mA |
AC-12 | 24V 50mA |
Mechanical values and environment
Degree of protection | |
in mounted condition (only access side) | IP67 |
Material | |
Housing | PA6-GF30, gray |
Installation orientation | on the front |
Mounting cut-out according to DIN IEC 61554 | 33x68 mm |
Ambient temperature | 0 ... +55 °C |
PROFINET interface | |
Connection | |
RJ-45 socket | |
star topology wiring |
Miscellaneous
Parameters for the outputs LA and LB | |
Additional feature | |
35 Resistance in switched-on state in ohm | |
max. 1 Capacitive load per output in µF |
Interface, bus
PROFINET interface | |
Data protocol | PROFINET |
Data rate | 10/100 Mbit/s |
Date interface | Ethernet (IEEE 802.3) |
Tartozékok
Electronic-Key
Electronic-Key read/write

077859
EKS-A-K1RDWT32-EU
EKS-A-K1RDWT32-EU
- Memory 116 bytes E²PROM (programmable) plus 8 bytes ROM (serial number)

094839
EKS-A-K1GNWT32-EU
EKS-A-K1GNWT32-EU
- Memory 116 bytes E²PROM (programmable) plus 8 bytes ROM (serial number)

123098
EKS-A-K1OGWT32-EU
EKS-A-K1OGWT32-EU
- Memory 116 bytes E²PROM (programmable) plus 8 bytes ROM (serial number)

091045
EKS-A-K1BUWT32-EU
EKS-A-K1BUWT32-EU
- Memory 116 bytes E²PROM (programmable) plus 8 bytes ROM (serial number)

094840
EKS-A-K1YEWT32-EU
EKS-A-K1YEWT32-EU
- Memory 116 bytes E²PROM (programmable) plus 8 bytes ROM (serial number)

123097
EKS-A-K1WHWT32-EU
EKS-A-K1WHWT32-EU
- Memory 116 bytes E²PROM (programmable) plus 8 bytes ROM (serial number)

084735
EKS-A-K1BKWT32-EU
EKS-A-K1BKWT32-EU
- Memory 116 bytes E²PROM (programmable) plus 8 bytes ROM (serial number)
Letöltések
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Instructions
Manual EKS and EKS FSA with PROFINET IO interface Compact from V3.X.X / Modular from V1.1.X
Dok. sz.
Változat
Nyelv
Méret

Manual EKS and EKS FSA with PROFINET IO interface Compact from V3.X.X / Modular from V1.1.X
Dok. sz.
2516210
Változat
01-06/18
Nyelv
Méret
2,5 MB

Handbuch EKS und EKS FSA mit PROFINET IO-Schnittstelle Kompakt ab V3.X.X / Modular ab V1.1.X
Dok. sz.
2516210
Változat
01-06/18
Nyelv
Méret
2,3 MB
Other Documents
Application examples
EKS FSA on Siemens S7-300 – selection of operating mode with touchscreen – Practical implementation
Dok. sz.
Változat
Nyelv
Méret

EKS FSA on Siemens S7-300 – selection of operating mode with touchscreen – Practical implementation
Dok. sz.
AP000169-7-2
Változat
02-06/19
Nyelv
Méret
1,9 MB

EKS FSA an Siemens S7-300 – Betriebsartenwahl mit Touchscreen – Praktische Umsetzung
Dok. sz.
AP000169-7-2
Változat
02-06/19
Nyelv
Méret
2,0 MB
EUCHNER EKS FSA Research Report
Dok. sz.
Változat
Nyelv
Méret

EUCHNER EKS FSA Research Report
Dok. sz.
AP000169-IFA
Változat
01-09/15
Nyelv
Méret
0,2 MB

Untersuchungsbericht IFA - Verfahren zur Realisierung der Betriebsartenwahl an Maschinen unter Nutzung des EKS FSA als Zugangssystem
Dok. sz.
AP000169-IFA
Változat
01-09/15
Nyelv
Méret
1,0 MB
Approvals and certificates
ProfiNET
Dok. sz.
Változat
Nyelv
Méret

ProfiNET
Dok. sz.
Változat
Nyelv
Méret
0,1 MB
c UL us
Dok. sz.
Változat
Nyelv
Méret

c UL us
Dok. sz.
Változat
Nyelv
Méret
1,8 MB
Sales documentation
Electronic-Key-System EKS
Dok. sz.
Változat
Nyelv
Méret

Electronic-Key-System EKS
Dok. sz.
086809
Változat
15-07/19
Nyelv
Méret
11,0 MB

Electronic-Key-System EKS
Dok. sz.
092953
Változat
15-07/19
Nyelv
Méret
11,0 MB

Electronic-Key-System EKS
Dok. sz.
114432
Változat
15-07/19
Nyelv
Méret
11,2 MB

Electronic-Key-System EKS
Dok. sz.
086808
Változat
15-07/19
Nyelv
Méret
11,0 MB
Ordering data
Rend. sz. | 106306 |
Articlename | EKS-A-IIXA-G01-ST02/03/04 |
Weight | 0,194kg |
Customsclass | 85365019 |