EUCHNER – More than safety.
EUCHNER – More than safety.

NZ1VZ-2131E3VSE07-M (Order no. 088036)

Safety switch NZ.VZ.VSE (guard locking, open-circuit current principle)

  • Housing according to EN 50041
  • Cable entry M20 x 1.5
NZ1VZ-2131E3VSE07-M (Order no. 088036)

Description

Approach direction

Figure

Figure

Horizontal

Can be adjusted in 90° steps

Guard locking type

VSEOpen-circuit current principle, guard locking by applying voltage to the solenoid. Release by spring force.

Switching element

2131HSlow-action switching contact 3 NC + 1 NO
Dimension drawing
Dimension drawing
2131H
2131H
Switching functions
Switching functions
Electro-mechanical safety switches

Dimension drawing

Dimension drawing
aTravel without operation: actuator is in the guide slot, but function is not triggered.
bSwitching operation completed: actuator must be inserted to this point to ensure reliable switching. The actuator must be withdrawn at least to point a for switching off.

2131H

2131H

Switching functions

Switching functions

Technical data

Approvals

Zulassung EACZulassung DNV GLZulassung c_UL_us LISTEDZulassung CCC

Mechanical values and environment

Housing material
Housing Anodized die-cast alloy
Weight
Net 0,7 kg
Ambient temperature -25 ... 80 °C
Degree of protection IP65
Mechanical life 2 x 106
Contact material Silver alloy, gold flashed
Switching principle Slow-action switching contact
Solenoid alignment 3
Installation orientation Any
Number of door position positively driven contacts 3
Number of door position NO contacts 1
Connection
1 x M20 x 1.5
Approach speed max.20 m/min
Actuation frequency max.1200 1/h
Guard locking principle Open-circuit current principle
Locking force Fmax 2000 N
Locking force FZh 1500 N
Retention force 35 N
Extraction force 40 N
Actuating force 45 N
Insertion depth 52 mm

Electrical connection ratings

Thermal rated current Ith 4 A
Utilization category according to EN 60947-5-1
AC-15 4A 230V
DC-13 4A 24V
Solenoid operating voltage
AC 110 V -15 ... 10
Short circuit protection according to IEC 60269-1 4A gG
Rated insulation voltage Ui
AC/DC 250 V
Rated impulse withstand voltage Uimp 2,5 kV
Switching voltage
Min. at 10mA 12 V
Switching current
Min. at 24V 1 mA
Connection cross-section 0,34 ... 1,5 mm²

Reliability values according to EN ISO 13849-1

Control of the guard locking
Category Depending on external control of guard locking
Performance Level Depending on external control of guard locking
PFHD Depending on external control of guard locking
Monitoring of the position of the safety guard
B10D 4,5 x 106

In combination with Actuator BETAETIGER-Z-GN

Mechanical values and environment

Overtravel 16 mm

In combination with Actuator BETAETIGER-Z-G

Mechanical values and environment

Overtravel 4 mm

Accessories

Downloads