CTP-L1-AP-U-HA-AZ-SA-127727 (Rend. sz. 127727)

Transponder-coded safety switch CTP-AP, M12

  • Safety switch with guard locking and integrated evaluation electronics
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4/PL e according to EN ISO 13849-1
  • With plug connector M12
  • Unicode
  • Door monitoring output
  • Approach directions A, B and C (delivery state)
CTP-L1-AP-U-HA-AZ-SA-127727 (Rend. sz. 127727)

Ismertetés

Approach direction

Horizontal

Can be adjusted in 90° steps

Unicode evaluation

Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.

Guard locking type

CTP‑L1

Guard locking actuated by spring force and power-ON released (closed-circuit current principle).

Connector assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1IMPOperating voltage of guard locking solenoid, 24 V DCWH
2UBOperating voltage of AP electronics, 24 V DCBN
3FO1ASafety output, channel 1GN
4FO1BSafety output, channel 2YE
5OLGuard lock monitoring outputGY
6ODDoor monitoring outputPK
70 V UBAP electronics operating voltage, 0 VBU
8IMMOperating voltage of guard locking solenoid, 0 VRD
Dimension drawing
Dimension drawing
Wiring drawing
Wiring drawing
CTP: Transponder coded safety switch CTP

Dimension drawings

Dimension drawings
1Auxiliary release
2Locking screw
3LEDs
4Plug connector aligned

Connection examples

Connection examples

Műszaki adatok

Approvals

EAC_RU C-DE.MO05.B.00971/20DGUV_CTP_ET 22017_ET 22018c_UL_us_E155795_3/11FCC_2AJ58-05_

Work area

Repeat accuracy R
according to EN 60947-5-2 10 %

Electrical connection ratings

Power consumption 6 W
Current consumption
IIMP 400 mA
IUB 40 mA
Fusing
external (solenoid operating voltage IMP) 0.5 ... 8 A
external (operating voltage UB) 0.25 ... 8 A
Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 0.5 kV
Operating voltage DC
UUB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple < 5%, PELV
EMC protection requirements according to EN IEC 60947-5-3
Utilization category
DC-13 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Solenoid operating voltage DC
UIMP 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple < 5%, PELV
Solenoid duty cycle 100 %
Switching load
according to UL 24V DC, Class 2 (alternatively, see operating instructions)
Safety class
EN IEC 61140 III
Test pulses max. 0.3 ms (Applies to a load with C <= 30 nF and R <= 20 kohm)
Test pulse interval min. 100 ms
Degree of contamination (external, according to EN 60947-1) 3
Monitoring output OD, OL
Output type p-switching, short circuit-proof
Output voltage 0.8xUB ... UB V DC
Switching current 1 ... 50 mA
Safety outputs FO1A/FO1B
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Discrepancy time
both safety outputs max. 10 ms according to EN IEC 60947-5-3
Output voltage
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
HIGH U(FO1A) / U(FO1B) UB-1.5 ... UB V DC
Turn-on time max. 400 ms
Switching current
per safety output FO1A / FO1B 1 ... 150 mA
Off-state current Ir max. 0.25 mA

Mechanical values and environment

Approach speed max. 20 m/min
Connection 1 plug connector M12, 8-pin
Degree of protection IP67/IP69/IP69K (screwed tight plug connector/mating component)
Extraction force 20 N
Ready delay max. 1 s
Material
Safety switch housing reinforced thermoplastic
Switch head cover Die-cast zinc
Actuating force 10 N
Mechanical life 1 x 10⁶
Installation orientation any
Switching frequency max. 0.5 Hz
Overtravel 5 mm
Retention force 20 N
Shock and vibration resistance according to EN IEC 60947-5-3
Ambient temperature
at UB = 24V DC -20 ... +55 °C
Locking force Fmax 3900 N
Locking force FZh 3000 N (Fzh = Fmax/1.3, depending on the actuator used)
Guard locking principle Closed-circuit current principle

Reliability values acc. to EN ISO 13849-1

Mission time 20 y
Category 4
Performance Level PL e
PFHD 4.1 x 10 -9

Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures; see operating instructions

Tartozékok

Letöltések

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download complete package (ZIP, 12,9 MB)

Single Documents

Other Documents

Ordering data

Rend. sz. 127727
Articlename CTP-L1-AP-U-HA-AZ-SA-127727
Weight 0,593kg
Customsclass 85365019